Skip to content
SafetyRecord logoSafetyRecord
ULBRICH PRECISION FLATWIRE
$11,920
penalties
26
viol.
5
insp.

ULBRICH PRECISION FLATWIRE

692 PLANT RD., WESTMINSTER, SC 29693NAICS 331221 Rolled Steel Shape Manufacturing

Inspections
5
Feb 2002 to Jun 2012 · 1 safety, 4 health
Violations
26
across 5 inspections
Penalties on record
$11,920
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 26, 2012Complaint (B) · Partial scope, Health#316206077$02 viol.

Inspection #316206077

Dates

Opened
Jun 26, 2012
Closing Conference Date
Aug 2, 2012
Closed
Sep 21, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
190
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
692 Plant Rd., Westminster, SC 29693
Industry
423510 Metal Service Centers and Other Metal Merchant Wholesalers

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 G01
Other113$0$0Sep 19, 2012--
010021910.1025
Lead
OSHA citation code: 19101025 H01
Other113$0$0Sep 19, 2012--
Sep 9, 2008Referral (C) · Partial scope, Safety#312165582$3,3606 viol.

Inspection #312165582

Dates

Opened
Sep 9, 2008
Closing Conference Date
Sep 9, 2008
Closed
Dec 9, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
177
Related Activity
1 referral

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$8,400
Penalties on Record
$3,360
Site Address
692 Plant Rd., Westminster, SC 29693
Industry
331221 Rolled Steel Shape Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
030011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Serious81$1,125$450Oct 21, 2008--
030021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 I
Serious41$1,500$600Oct 21, 2008--
030031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IV
Serious11$1,125$450Oct 21, 2008--
030041910.304
Wiring design and protection
OSHA citation code: 19100304 G06 VIC5
Serious11$900$360Oct 14, 2008--
030051910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 E01
Serious34$1,875$750Oct 21, 2008--
030061910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 E02
Serious14$1,875$750Oct 21, 2008--
Jul 29, 2008Planned (H) · Complete scope, Health#312166416$1,8003 viol.

Inspection #312166416

Dates

Opened
Jul 29, 2008
Closing Conference Date
Aug 29, 2008
Closed
Oct 9, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
177

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$1,800
Site Address
692 Plant Rd., Westminster, SC 29693
Industry
331221 Rolled Steel Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious15$900$900Sep 19, 2008--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious15$900$900Sep 19, 2008--
020011910.1025
Lead
OSHA citation code: 19101025 H02 II
Other110$0$0Sep 22, 2008--
Jan 16, 2003Follow-Up (F) · Partial scope, Health#300275161$00 viol.

Inspection #300275161

Dates

Opened
Jan 16, 2003
Closing Conference Date
Mar 6, 2003
Closed
Mar 14, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
91

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
692 Plant Rd., Westminster, SC 29693
Industry
331221 Rolled Steel Shape Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 13, 2002Planned (H) · Complete scope, Health#303561583$6,76015 viol.

Inspection #303561583

Dates

Opened
Feb 13, 2002
Closing Conference Date
Apr 23, 2002
Closed
Mar 14, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
91

Violations and Penalties

Total Violations
15
Violation Types
13 serious, 2 other-than-serious
Initial Penalties
$5,525
Penalties on Record
$6,760
Site Address
692 Plant Rd., Westminster, SC 29693
Industry
331221 Rolled Steel Shape Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
0100110012
OSHA citation code: 10012 A
Serious11$2,125$850Jul 15, 2002--
010031910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$1,275$510Jul 15, 2002--
010091910.1025
Lead
OSHA citation code: 19101025 J01 I
Serious11$2,125$850Aug 5, 2002--
01013A1910.132
General requirements
OSHA citation code: 19100132 A
Serious22$0$850Jul 8, 2002--
01013B1910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$0$0Aug 5, 2002--
01014A1910.1025
Lead
OSHA citation code: 19101025 F01
Serious11$0$2,000Aug 5, 2002--
01014B1910.1025
Lead
OSHA citation code: 19101025 G01
Serious11$0$0Aug 20, 2002--
01014C1910.1025
Lead
OSHA citation code: 19101025 C01
Serious11$0$0Nov 15, 2002--
01014D1910.1025
Lead
OSHA citation code: 19101025 E01 I
Serious11$0$0Nov 15, 2002--
01015A1910.1025
Lead
OSHA citation code: 19101025 I02 II
Serious11$0$850Aug 5, 2002--

Showing the 10 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead13 citations · $4,550
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $1,350
1910.217Mechanical Power Presses2 citations · $1,050

Industry comparison

Violations per inspection
This employer5.2
Industry average3.2
Penalties per inspection
This employer$2,384
Industry average$2,892

Primary Metal Manufacturing, 8,699 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WESTMINSTER, SC

All employers in WESTMINSTER →