Skip to content
SafetyRecord logoSafetyRecord
UNIVERSAL WEARPARTS INC
$9,605
penalties
46
viol.
4
insp.

UNIVERSAL WEARPARTS INC

HIGHWAY 98 WEST, Tylertown, MS 39667

Inspections
4
Jan 1984 to May 2003 · 1 safety, 3 health
Violations
46
across 4 inspections
Penalties on record
$9,605
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 7, 2003Monitoring (D) · Partial scope, Health#304319031$00 viol.

Inspection #304319031

Dates

Opened
May 7, 2003
Closing Conference Date
May 7, 2003
Closed
May 29, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
142 Old Hwy 98 W., Tylertown, MS 39667
Industry
332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30.0009122 - 0.0017518mg/m³
Chromium, Metal and Insoluble Salts30 - 0.0173333mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30mg/m³
Iron Oxide Fume30 - 0.3680684mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30 - 0.004652mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30 - 0.0152967mg/m³
Zinc Oxide Fume30mg/m³
Sep 5, 2002Complaint (B) · Partial scope, Health#304315336$7,75523 viol.

Inspection #304315336

Dates

Opened
Sep 5, 2002
Closing Conference Date
Sep 5, 2002
Closed
Jun 6, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25
Related Activity
1 complaint

Violations and Penalties

Total Violations
23
Violation Types
21 serious, 2 other-than-serious
Initial Penalties
$14,100
Penalties on Record
$7,755
Site Address
142 Old Hwy 98 W., Tylertown, MS 39667
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Cadmium60.0168197 - 0.0270496mg/m³
Chromium, Metal and Insoluble Salts60mg/m³
Cobalt, Metal, Dust and Fume (as Co)60mg/m³
Copper Fume (as Cu)60mg/m³
Iron Oxide Fume60 - 0.1028239mg/m³
Lead, Inorganic (as Pb)60 - 0.0222807mg/m³
Manganese Fume (as Mn)60mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60mg/m³
Nickel, Metal and Insoluble compounds (as Ni)60mg/m³
Vanadium fume (as V2O5)60mg/m³
Zinc Oxide Fume60mg/m³

Violations

Violation list (12 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.22
OSHA citation code: 19100022 A02
Serious125$450$250May 21, 2003--
01001B1910.22
OSHA citation code: 19100022 B01
Serious17$0$0Jan 13, 2003--
010021910.23
OSHA citation code: 19100023 C01
Serious12$600$250Feb 4, 2003--
010031910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$600$350Feb 26, 2003--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious120$600$250Jan 13, 2003--
01005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious115$600$250Jan 13, 2003--
01005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious120$0$0Jan 13, 2003--
010061910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious14$450$250Jan 14, 2003--
010071910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 III
Serious12$600$250Jan 21, 2003--
010081910.1027
Cadmium
OSHA citation code: 19101027 C
Serious13$1,500$1,200Jun 21, 2003--
010091910.1027
Cadmium
OSHA citation code: 19101027 D01 I
Serious13$1,500$1,100Jun 21, 2003--
010101910.1027
Cadmium
OSHA citation code: 19101027 E01
Serious13$450$200Jun 21, 2003--

Showing the 12 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 20, 1993Planned (H) · Complete scope, Health#101393460$1,05012 viol.

Inspection #101393460

Dates

Opened
Jan 20, 1993
Closing Conference Date
Jan 21, 1993
Closed
Mar 16, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
12
Violation Types
4 serious, 8 other-than-serious
Initial Penalties
$1,800
Penalties on Record
$1,050
Site Address
Hwy 198 West, Tylertown, MS 39667
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious11$450$250Mar 15, 1993--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$450$250Mar 1, 1993--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Serious11$450$250Feb 16, 1993--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$450$300Mar 1, 1993--
020011904.2
OSHA citation code: 19040002 A
Other125$0$0Feb 15, 1993--
020021910.22
OSHA citation code: 19100022 A02
Other117$0$0Mar 15, 1993--
020031910.22
OSHA citation code: 19100022 D01
Other13$0$0Mar 1, 1993--
020041910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Other12$0$0Mar 15, 1993--
020051910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Other11$0$0Feb 16, 1993--
020061910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other121$0$0Mar 15, 1993--
020071910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Other1-$0$0Mar 15, 1993--
020081910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other11$0$0Mar 15, 1993--
Jan 19, 1984Planned (H) · Complete scope, Safety#13540513$80011 viol.

Inspection #13540513

Dates

Opened
Jan 19, 1984
Closing Conference Date
Jan 19, 1984
Contested
Apr 30, 1984
Closed
Mar 16, 2016

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
11
Violation Types
7 serious, 4 other-than-serious
Initial Penalties
$800
Penalties on Record
$800
Site Address
Highway 98 West, Tylertown, MS 39667
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious1-$120$120Mar 1, 1984Apr 30, 1984-
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious1-$120$120Mar 1, 1984Apr 30, 1984-
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Serious1-$200$200Mar 1, 1984Apr 30, 1984-
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious1-$160$160Mar 1, 1984Apr 30, 1984-
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious1-$0$0Mar 1, 1984Apr 30, 1984-
01005A1910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious1-$200$200Mar 1, 1984Apr 30, 1984-
01005B1910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious1-$0$0Mar 1, 1984Apr 30, 1984-
020011904.2
OSHA citation code: 19040002 A
Other1-$0$0Mar 1, 1984Apr 30, 1984-
020021910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 H06 IIB
Other1-$0$0Mar 1, 1984Apr 30, 1984-
020031910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 H12
Other1-$0$0Mar 1, 1984Apr 30, 1984-
020041910.303
OSHA citation code: 19100303 F
Other1-$0$0Mar 1, 1984Apr 30, 1984-
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1027Cadmium10 citations · $5,400
1910.219Mechanical Power-Transmission Apparatus5 citations · $710
1910.1200Hazard Communication5 citations · $205

Chemical exposure sampling

Samples
117
Substances
13
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in Tylertown, MS