U.S. DEPT OF THE NAVY

NAVAL AIR STATION, JACKSONVILLE, FL 32212

Inspections
46
Mar 1987 to Jun 2009 · 16 safety, 30 health
Violations
142
across 46 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 79Willful 1Repeat 10Other 52

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 2, 2009Complaint (B) · Complete scope, Health#311822092$01 viol.

Inspection #311822092

Dates

Opened
Jun 2, 2009
Closing Conference Date
Nov 6, 2009
Closed
Dec 19, 2009

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
9
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Oxygen Shop, Fleet Readiness Center Southeast, Jacksonville, FL 32212
Industry
921190

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)290mg/m³
Beryllium and Beryllium Compounds (as Be)290mg/m³
Cadmium290mg/m³
Chromic Acid and Chromates (as CrO3)110mg/m³
Chromium, Metal and Insoluble Salts290 - 0.0578051mg/m³
Chromium (VI) - TWA110mg/m³
Cobalt, Metal, Dust and Fume (as Co)290mg/m³
Copper Fume (as Cu)290mg/m³
Iron Oxide Fume290 - 0.2685545mg/m³
Lead, Inorganic (as Pb)290 - 0.4676864mg/m³
Manganese Fume (as Mn)290mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)290mg/m³
Nickel, Metal and Insoluble compounds (as Ni)290mg/m³
Vanadium fume (as V2O5)290mg/m³
Zinc Oxide Fume290.0977423 - 0.4696923mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 L01 I
Other16$0$0Dec 7, 2009--
Feb 7, 2003Unprogrammed Other (J) · Partial scope, Safety#303991541$00 viol.

Inspection #303991541

Dates

Opened
Feb 7, 2003
Closing Conference Date
Feb 7, 2003
Closed
Feb 7, 2003

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
45

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Nas Jacksonville, Jacksonville, FL 32212
Industry
928110

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Sep 25, 2002Complaint (B) · Partial scope, Health#303989990$02 viol.

Inspection #303989990

Dates

Opened
Sep 25, 2002
Closing Conference Date
Jan 16, 2003
Closed
Feb 28, 2003

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
43
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Naval Air Depot, Building 797, Jacksonville, FL 32212
Industry
928110

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)80mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Cadmium80mg/m³
Chromium, Metal and Insoluble Salts80mg/m³
Cobalt, Metal, Dust and Fume (as Co)80 - 0.0176878mg/m³
Copper Fume (as Cu)80mg/m³
Iron Oxide Fume80mg/m³
Lead, Inorganic (as Pb)80mg/m³
Manganese Fume (as Mn)80mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)80mg/m³
Nickel, Metal and Insoluble compounds (as Ni)80 - 0.0567435mg/m³
Vanadium fume (as V2O5)80mg/m³
Zinc Oxide Fume80mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$0$0Jan 29, 2003--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 H03 II
Other16$0$0Feb 26, 2003--
Mar 23, 2001Unprogrammed Other (J) · Partial scope, Health#303983951$00 viol.

Inspection #303983951

Dates

Opened
Mar 23, 2001
Closing Conference Date
Mar 23, 2001
Closed
Mar 23, 2001

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
49

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Nas Jacksonville, Jacksonville, FL 32212
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Mar 9, 2001Unprogrammed Other (J) · Partial scope, Health#303983811$00 viol.

Inspection #303983811

Dates

Opened
Mar 9, 2001
Closing Conference Date
Mar 9, 2001
Closed
Mar 9, 2001

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
54

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Nas Jacksonville, Jacksonville, FL 32212
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Nov 14, 2000Unprogrammed Related (G) · Partial scope, Health#302740329$00 viol.

Inspection #302740329

Dates

Opened
Nov 14, 2000
Closing Conference Date
Dec 19, 2000
Closed
Dec 21, 2000

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
600
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Naval Hospital-Nas 2080 Child St., Jacksonville, FL 32214
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 1, 1998Unprogrammed Other (J) · Partial scope, Health#301025524$00 viol.

Inspection #301025524

Dates

Opened
Oct 1, 1998
Closing Conference Date
Oct 1, 1998
Closed
Oct 1, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
No
Number of Employees
600

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Bldg 448 Bon Homme, Jacksonville, FL 32225
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 1, 1998Complaint (B) · Partial scope, Health#301025490$00 viol.

Inspection #301025490

Dates

Opened
Oct 1, 1998
Closing Conference Date
Oct 5, 1998
Closed
Oct 5, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
3,999
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Bldg 101, Nc Machinery Area, Jacksonville, FL 32212
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Sep 30, 1998Unprogrammed Other (J) · Partial scope, Health#301025482$00 viol.

Inspection #301025482

Dates

Opened
Sep 30, 1998
Closing Conference Date
Sep 30, 1998
Closed
Sep 30, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
No
Number of Employees
600

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Bldg 448 Bon Homme, Jacksonville, FL 32225
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jan 7, 1998Unprogrammed Other (J) · Partial scope, Health#301021796$00 viol.

Inspection #301021796

Dates

Opened
Jan 7, 1998
Closing Conference Date
Jan 7, 1998
Closed
Jan 7, 1998

Inspection

Advance Notice
Yes
Owner Type
Federal
Union Status
No
Number of Employees
600

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Ocean Breeze Conference Center, Jacksonville, FL 32225
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Inspections 1 to 10 of 46, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication18 citations · $0
1910.134Respiratory Protection17 citations · $0
1910.212General Requirements for All Machines (Machine Guarding)9 citations · $0

Chemical exposure sampling

Samples
549
Substances
18
Inspections
4

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in JACKSONVILLE, FL

All employers in JACKSONVILLE →