Skip to content
SafetyRecord logoSafetyRecord
U.S. POSTAL SERVICE
$0
penalties
10
viol.
5
insp.

U.S. POSTAL SERVICE

BUILDING 724, FORT RICHARDSON, AK 99505

Inspections
5
Jul 1991 to Sep 1998 · 4 safety, 1 health
Violations
10
across 5 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 18, 1998Follow-Up (F) · Partial scope, Safety#301495164$00 viol.

Inspection #301495164

Dates

Opened
Sep 18, 1998
Closing Conference Date
Sep 18, 1998
Closed
Oct 30, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Building 724, Fort Richardson, AK 99505
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 12, 1998Planned (H) · Complete scope, Safety#301494811$04 viol.

Inspection #301494811

Dates

Opened
Jun 12, 1998
Closing Conference Date
Jun 12, 1998
Closed
Oct 30, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
9

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Building 724, Fort Richardson, AK 99505
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$0$0Jul 15, 1998--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious19$0$0Aug 4, 1998--
010031910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious1-$0$0Jul 9, 1998--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other11$0$0Jul 9, 1998--
Jun 12, 1998Planned (H) · Complete scope, Health#18167221$00 viol.

Inspection #18167221

Dates

Opened
Jun 12, 1998
Closing Conference Date
Jun 12, 1998
Closed
Jun 18, 1998

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Building 724, Fort Richardson, AK 99505
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 18, 1993Unprogrammed Other (J) · Complete scope, Safety#109433300$00 viol.

Inspection #109433300

Dates

Opened
Nov 18, 1993
Closing Conference Date
Nov 18, 1993
Closed
Aug 26, 1994

Inspection

Advance Notice
Yes
Owner Type
Federal
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Building 724, Fort Richardson, AK 99505
Industry
Not classified in OSHA's inspection record.

Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jul 26, 1991Complaint (B) · Partial scope, Safety#107107351$06 viol.

Inspection #107107351

Dates

Opened
Jul 26, 1991
Closing Conference Date
Jul 26, 1991
Closed
Oct 7, 1991

Inspection

Advance Notice
No
Owner Type
Federal
Union Status
Yes
Number of Employees
10
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Building 724, Fort Richardson, AK 99505
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious110$0$0Sep 10, 1991--
01001B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Serious810$0$0Sep 10, 1991--
01002A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious210$0$0Aug 28, 1991--
01002B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious110$0$0Aug 28, 1991--
01003A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious110$0$0Sep 10, 1991--
01003B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious110$0$0Sep 10, 1991--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.303Electrical - General Requirements3 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.1200Hazard Communication2 citations · $0

Other inspected employers in FORT RICHARDSON, AK

All employers in FORT RICHARDSON →