U.S. POSTAL SERVICE
300 PACKERLAND DRIVE, GREEN BAY, WI 54303 · NAICS 491110
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 17, 1996#122482466Jun 17, 1996Planned (H) · Complete scope, Safety#122482466$02 viol.2 violations$0 in penalties
Inspection #122482466
Dates
- Opened
- Jun 17, 1996
- Closing Conference Date
- Jun 17, 1996
- Closed
- Jul 18, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 500
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 300 Packerland Drive, Green Bay, WI 54303
- Industry
- 491110
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 2 | $0 | $0 | Jul 15, 1996 | - | - |
| 01002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Other | 1 | 1 | $0 | $0 | Jul 15, 1996 | - | - |
Jul 27, 1994#103519344Jul 27, 1994Complaint (B) · Partial scope, Safety#103519344$01 viol.1 violation$0 in penalties
Inspection #103519344
Dates
- Opened
- Jul 27, 1994
- Closing Conference Date
- Jul 27, 1994
- Closed
- Sep 19, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 375
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 300 Packerland Drive, Green Bay, WI 54303
- Industry
- 491110
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 1 | $0 | $0 | Sep 8, 1994 | - | - |
Sep 7, 1988#102539855Sep 7, 1988Planned (H) · Complete scope, Safety#102539855$010 viol.10 violations$0 in penalties
Inspection #102539855
Dates
- Opened
- Sep 7, 1988
- Closing Conference Date
- Sep 8, 1988
- Closed
- Jan 13, 1989
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 1,900
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 7 serious, 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 300 Packerland Drive, Green Bay, WI 54303
- Industry
- 491110
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 B01 | Serious | 1 | 10 | $0 | $0 | Dec 20, 1988 | - | - |
| 01001B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 III | Serious | 1 | 10 | $0 | $0 | Jan 5, 1989 | - | - |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 10 | $0 | $0 | Dec 20, 1988 | - | - |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F01 | Serious | 1 | 10 | $0 | $0 | Dec 20, 1988 | - | - |
| 01002C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Serious | 1 | 10 | $0 | $0 | Dec 20, 1988 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 1 | $0 | $0 | Dec 6, 1988 | - | - |
| 01004 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 B04 IXC | Serious | 1 | 5 | $0 | $0 | Dec 6, 1988 | - | - |
| 02001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 K02 | Other | 1 | 1 | $0 | $0 | Dec 6, 1988 | - | - |
| 02002 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A02 IVC | Other | 1 | 5 | $0 | $0 | Dec 12, 1988 | - | - |
| 02003 | 1910.1001 Asbestos OSHA citation code: 19101001 D02 I | Other | 1 | 5 | $0 | $0 | Jan 5, 1989 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
13 inspections, 1988 to 2025. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
NAICS 491, 2,234 employers with OSHA inspections. Arithmetic from DOL records.