USDOL OSHA - MILWAUKEE
310 W. WISCONSIN AVE. SUITE 1180, MILWAUKEE, WI 53203 · NAICS 926150
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Feb 16, 2010#313525735Feb 16, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525735$00 viol.0 violations$0 in penalties
Inspection #313525735
Dates
- Opened
- Feb 16, 2010
- Closing Conference Date
- Feb 16, 2010
- Closed
- Feb 16, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 22
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium | 1 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0 | mg/m³ |
| Heptane (n-Heptane) | 6 | 1.187769 - 4.566277 | ppm |
| Iron Oxide Fume | 1 | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0 | mg/m³ |
Feb 10, 2010#313525693Feb 10, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525693$00 viol.0 violations$0 in penalties
Inspection #313525693
Dates
- Opened
- Feb 10, 2010
- Closing Conference Date
- Feb 10, 2010
- Closed
- Feb 10, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 23
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling3 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Butadiene | 2 | 0 | ppm |
| Stoddard Solvent | 2 | 0 | mg/m³ |
| Styrene | 2 | 0 | ppm |
Feb 9, 2010#313525644Feb 9, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525644$00 viol.0 violations$0 in penalties
Inspection #313525644
Dates
- Opened
- Feb 9, 2010
- Closing Conference Date
- Feb 9, 2010
- Closed
- Feb 9, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 22
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Refractory Ceramic Fibers | 4 | 0.1203 - 0.2049 | f/cc |
Feb 2, 2010#313526246Feb 2, 2010Unprogrammed Other (J) · No Inspection scope, Health#313526246$00 viol.0 violations$0 in penalties
Inspection #313526246
Dates
- Opened
- Feb 2, 2010
- Closing Conference Date
- Feb 2, 2010
- Closed
- Feb 2, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 24
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Feb 2, 2010#313525537Feb 2, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525537$00 viol.0 violations$0 in penalties
Inspection #313525537
Dates
- Opened
- Feb 2, 2010
- Closing Conference Date
- Feb 2, 2010
- Closed
- Feb 2, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium | 1 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0 | mg/m³ |
| Iron Oxide Fume | 1 | 0.0410915 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Stoddard Solvent | 4 | 0 - 85.509778 | mg/m³ |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0 | mg/m³ |
Feb 1, 2010#313526105Feb 1, 2010Unprogrammed Other (J) · No Inspection scope, Health#313526105$00 viol.0 violations$0 in penalties
Inspection #313526105
Dates
- Opened
- Feb 1, 2010
- Closing Conference Date
- Feb 1, 2010
- Closed
- Feb 1, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 24
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling3 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Asbestos (all forms) | 1 | 0 | f/cc |
| Gravimetric DeterminationQC | 1 | 0.0305 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 1 | 0.0305 | mg/m³ |
| Sample WeightQC | 1 | 0.018 | mg |
| Silica, Crystalline Quartz (Respirable Fraction) | 1 | 0 | % |
Jan 26, 2010#313525453Jan 26, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525453$00 viol.0 violations$0 in penalties
Inspection #313525453
Dates
- Opened
- Jan 26, 2010
- Closing Conference Date
- Jan 26, 2010
- Closed
- Jan 26, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 23
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Gravimetric DeterminationQC | 1 | 0.7593 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 1 | 0.7593 | mg/m³ |
| Sample WeightQC | 1 | 0.733 | mg |
Jan 26, 2010#313525446Jan 26, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525446$00 viol.0 violations$0 in penalties
Inspection #313525446
Dates
- Opened
- Jan 26, 2010
- Closing Conference Date
- Jan 26, 2010
- Closed
- Jan 26, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Gravimetric DeterminationQC | 1 | 0.2073 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 1 | 0.2073 | mg/m³ |
| Sample WeightQC | 1 | 0.1895 | mg |
Jan 15, 2010#313525297Jan 15, 2010Unprogrammed Other (J) · No Inspection scope, Health#313525297$00 viol.0 violations$0 in penalties
Inspection #313525297
Dates
- Opened
- Jan 15, 2010
- Closing Conference Date
- Jan 15, 2010
- Closed
- Jan 15, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Not recorded
- Number of Employees
- 23
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Gravimetric DeterminationQC | 1 | 1.065 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 1 | 1.065 | mg/m³ |
| Sample WeightQC | 1 | 0.925 | mg |
Jan 14, 2010#313525438Jan 14, 2010Unprogrammed Other (J) · No Inspection scope, Safety#313525438$00 viol.0 violations$0 in penalties
Inspection #313525438
Dates
- Opened
- Jan 14, 2010
- Closing Conference Date
- Jan 14, 2010
- Closed
- Jan 14, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 310 W. Wisconsin Ave. Suite 1180, Milwaukee, WI 53203
- Industry
- 926150
Unprogrammed Other Inspection: This inspection record is categorized as an unprogrammed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
50 inspections, 2015 to 2021. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
The timeline shows the 50 most recent of 347 inspections with a recorded opening date.
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Public Administration, 4,116 employers with OSHA inspections. Arithmetic from DOL records.