VAN BUREN TN PARKS & REC DEPT
SR 48, Baldwinsville, NY 13027
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 14, 2011#315326611Oct 14, 2011Follow-Up (F) · Partial scope, Safety#315326611$00 viol.0 violations$0 in penalties
Inspection #315326611
Dates
- Opened
- Oct 14, 2011
- Closing Conference Date
- Oct 14, 2011
- Closed
- Oct 14, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 7350 Canton St, Baldwinsville, NY 13027
- Industry
- 712190 Nature Parks and Other Similar Institutions
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Aug 24, 2011#315326017Aug 24, 2011Monitoring (D) · Partial scope, Safety#315326017$00 viol.0 violations$0 in penalties
Inspection #315326017
Dates
- Opened
- Aug 24, 2011
- Closing Conference Date
- Aug 24, 2011
- Closed
- Oct 14, 2011
Inspection
- Advance Notice
- Yes
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 7350 Canton St, Baldwinsville, NY 13027
- Industry
- 713940 Fitness and Recreational Sports Centers
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Jun 29, 2011#313568115Jun 29, 2011Planned (H) · Complete scope, Safety#313568115$09 viol.9 violations$0 in penalties
Inspection #313568115
Dates
- Opened
- Jun 29, 2011
- Closing Conference Date
- Jun 29, 2011
- Closed
- Oct 17, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 7
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 9 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 7350 Canton St, Baldwinsville, NY 13027
- Industry
- 713940 Fitness and Recreational Sports Centers
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.37 OSHA citation code: 19100037 B02 | Serious | 1 | 7 | $0 | $0 | Sep 16, 2011 | - | - |
| 01002 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C02 II | Serious | 1 | 9 | $0 | $0 | Sep 16, 2011 | - | - |
| 01003 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 7 | $0 | $0 | Oct 28, 2011 | - | - |
| 01004 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C01 | Serious | 1 | 9 | $0 | $0 | Sep 16, 2011 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 7 | $0 | $0 | Sep 16, 2011 | - | - |
| 01006 | 1910.303 OSHA citation code: 19100303 B01 | Serious | 1 | 7 | $0 | $0 | Aug 26, 2011 | - | - |
| 01007 | 1910.303 OSHA citation code: 19100303 B02 | Serious | 5 | 7 | $0 | $0 | Sep 16, 2011 | - | - |
| 01008 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 J01 I | Serious | 1 | 7 | $0 | $0 | Aug 26, 2011 | - | - |
| 01009 | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 II | Serious | 1 | 7 | $0 | $0 | Sep 16, 2011 | - | - |
Feb 12, 2001#124567025Feb 12, 2001Follow-Up (F) · Partial scope, Safety#124567025$00 viol.0 violations$0 in penalties
Inspection #124567025
Dates
- Opened
- Feb 12, 2001
- Closing Conference Date
- Feb 12, 2001
- Closed
- Feb 23, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sr 48, Baldwinsville, NY 13027
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Sep 21, 2000#300066255Sep 21, 2000Planned (H) · Complete scope, Safety#300066255$010 viol.10 violations$0 in penalties
Inspection #300066255
Dates
- Opened
- Sep 21, 2000
- Closing Conference Date
- Oct 12, 2000
- Closed
- Feb 23, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 4 serious, 6 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sr 48, Baldwinsville, NY 13027
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.136 Foot Protection OSHA citation code: 19100136 A | Serious | 1 | 3 | $0 | $0 | Feb 22, 2001 | - | - |
| 01002 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 3 | $0 | $0 | Jan 31, 2001 | - | - |
| 01003 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B02 | Serious | 1 | 3 | $0 | $0 | Nov 24, 2000 | - | - |
| 01004 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G01 III | Serious | 1 | 7 | $0 | $0 | Jan 31, 2001 | - | - |
| 02001 | 1910.132 General requirements OSHA citation code: 19100132 F01 | Other | 1 | 3 | $0 | $0 | Feb 22, 2001 | - | - |
| 02002 | 1910.144 Safety Color Code for Marking Physical Hazards OSHA citation code: 19100144 A03 | Other | 1 | 6 | $0 | $0 | Dec 15, 2000 | - | - |
| 02003 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I | Other | 1 | 3 | $0 | $0 | Feb 22, 2001 | - | - |
| 02004 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 1 | 3 | $0 | $0 | Dec 15, 2000 | - | - |
| 02005 | 1910.303 OSHA citation code: 19100303 G02 II | Other | 1 | 6 | $0 | $0 | Nov 24, 2000 | - | - |
| 02006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Other | 1 | 3 | $0 | $0 | Feb 22, 2001 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 2000 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.