Skip to content
SafetyRecord logoSafetyRecord
VARCO-PRUDEN BUILDINGS
$2,000
penalties
11
viol.
3
insp.

VARCO-PRUDEN BUILDINGS

2622 WEST 17TH, PINE BLUFF, AR 71603

Inspections
3
Aug 1990 to Dec 2009 · 3 safety, 0 health
Violations
11
across 3 inspections
Penalties on record
$2,000
latest amounts in DOL records
By classification
Serious 10Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 22, 2009Planned (H) · No Inspection scope, Safety#313886210$00 viol.

Inspection #313886210

Dates

Opened
Dec 22, 2009
Closing Conference Date
Not recorded
Closed
Dec 22, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2622 W. 17th Street, Pine Bluff, AR 71603
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 21, 1996Planned (H) · Complete scope, Safety#300212867$00 viol.

Inspection #300212867

Dates

Opened
Jun 21, 1996
Closing Conference Date
Jun 21, 1996
Closed
Jan 5, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
120

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2622 West 17th, Pine Bluff, AR 71603
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 16, 1990Complaint (B) · Complete scope, Safety#103479945$2,00011 viol.

Inspection #103479945

Dates

Opened
Aug 16, 1990
Closing Conference Date
Aug 17, 1990
Closed
Oct 17, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
249
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$3,770
Penalties on Record
$2,000
Site Address
2622 West 17th, Pine Bluff, AR 71603
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious33$280$150Oct 11, 1990--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious34$490$350Oct 20, 1990--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious22$420$210Oct 3, 1990--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious11$420$210Oct 3, 1990--
010061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious21$210$105Sep 26, 1990--
010071910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Serious11$350$175Sep 17, 1990--
010081910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D09 III
Serious11$350$175Sep 17, 1990--
010091910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Other22$0$0Sep 26, 1990--
010101910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious11$420$210Sep 17, 1990--
010111910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$350$175Sep 17, 1990--
010121910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious1010$480$240Sep 26, 1990--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.304Electrical - Wiring Design and Protection3 citations · $625
1910.213Woodworking Machinery Requirements2 citations · $420
1910.215Abrasive Wheel Machinery1 citation · $105

Industry comparison

BLS 2024 survey: prefabricated metal building and component manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PINE BLUFF, AR