VIRGINIA DEPARTMENT OF TRANSPORTATION
SANDSTON RESIDENCY SHOP, 6060 ELKO TRACT ROAD, Sandston, VA 23150
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 18, 2003#305643850Mar 18, 2003Planned (H) · Complete scope, Safety#305643850$02 viol.2 violations$0 in penalties
Inspection #305643850
Dates
- Opened
- Mar 18, 2003
- Closing Conference Date
- Mar 18, 2003
- Closed
- May 5, 2003
Inspection
- Advance Notice
- No
- Owner Type
- State government
- Union Status
- No
- Number of Employees
- 21
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sandston Residency & Elko Hdqt. 6000 Elko Tract Rd, Sandston, VA 23150
- Industry
- 811111 General Automotive Repair
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 D01 II | Serious | 2 | 5 | $0 | $0 | Apr 16, 2003 | - | - |
| 02001 | 1910.22 OSHA citation code: 19100022 D01 | Other | 1 | 5 | $0 | $0 | Apr 16, 2003 | - | - |
Dec 3, 2002#305649519Dec 3, 2002Planned (H) · Complete scope, Safety#305649519$012 viol.12 violations$0 in penalties
Inspection #305649519
Dates
- Opened
- Dec 3, 2002
- Closing Conference Date
- Jan 9, 2003
- Closed
- Feb 27, 2003
Inspection
- Advance Notice
- No
- Owner Type
- State government
- Union Status
- No
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 6 serious, 6 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sandston Residency Shop, 6060 Elko Tract Road, Sandston, VA 23150
- Industry
- 811111 General Automotive Repair
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 B | Serious | 1 | 10 | $0 | $0 | Mar 26, 2003 | - | - |
| 01002 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 L01 | Serious | 2 | 10 | $0 | $0 | Mar 26, 2003 | - | - |
| 01003 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 L03 III | Serious | 1 | 10 | $0 | $0 | Mar 5, 2003 | - | - |
| 01004 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 M01 | Serious | 2 | 10 | $0 | $0 | Mar 5, 2003 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Serious | 1 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
| 01006 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Serious | 3 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
| 02001 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 | Other | 2 | 10 | $0 | $0 | Mar 5, 2003 | - | - |
| 02002 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J03 | Other | 2 | 10 | $0 | $0 | Mar 5, 2003 | - | - |
| 02003 | 1910.303 OSHA citation code: 19100303 B02 | Other | 2 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
| 02004 | 1910.303 OSHA citation code: 19100303 F | Other | 2 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
| 02005 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G01 IIIA | Other | 1 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
| 02006 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 III | Other | 1 | 10 | $0 | $0 | Jan 22, 2003 | - | - |
Jun 17, 1997#125455907Jun 17, 1997Planned (H) · Complete scope, Safety#125455907$01 viol.1 violation$0 in penalties
Inspection #125455907
Dates
- Opened
- Jun 17, 1997
- Closing Conference Date
- Jun 18, 1997
- Closed
- Jul 5, 1997
Inspection
- Advance Notice
- No
- Owner Type
- State government
- Union Status
- No
- Number of Employees
- 6
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Sandston Residency Shop, 6060 Elko Tract Road, Sandston, VA 23150
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.243 Guarding of Portable Powered Tools OSHA citation code: 19100243 C01 | Serious | 1 | 5 | $0 | $0 | Jul 5, 1997 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1997 to 2003. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: automotive repair and maintenance reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.8%; NAICS 8111 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source