Skip to content
SafetyRecord logoSafetyRecord
WARD MANUFACTURING INC.
$48,719
penalties
90
viol.
24
insp.

WARD MANUFACTURING INC.

115 GULICK STREET, Blossburg, PA 16912NAICS 332996 Fabricated Pipe and Pipe Fitting Manufacturing

Inspections
24
Apr 1987 to Jun 2022 · 11 safety, 13 health
Violations
90
across 24 inspections
Penalties on record
$48,719
latest amounts in DOL records
By classification
Serious 60Willful 0Repeat 1Other 29

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 14, 1993Complaint (B) · Partial scope, Health#106464654$4,4006 viol.

Inspection #106464654

Dates

Opened
Sep 14, 1993
Closing Conference Date
Oct 8, 1993
Closed
Dec 19, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
825
Related Activity
4 complaints

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$10,500
Penalties on Record
$4,400
Site Address
115 Gulick Street, Blossburg, PA 16912
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Silica, Crystalline Quartz (Respirable Fraction)416 - 27%

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious535$2,625$1,000Dec 31, 1995--
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Other11$2,625$0Jan 24, 1994--
010031910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious130$2,625$1,700Jan 9, 1994--
01004A1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious230$2,625$1,700Nov 30, 1996--
01004B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious230$0$0Nov 30, 1996--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D03
Other135$0$0Jan 24, 1994--
Oct 16, 1989Complaint (B) · Partial scope, Health#18224170$56019 viol.

Inspection #18224170

Dates

Opened
Oct 16, 1989
Closing Conference Date
Jan 3, 1990
Closed
May 29, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
658
Related Activity
2 complaints

Violations and Penalties

Total Violations
19
Violation Types
4 serious, 15 other-than-serious
Initial Penalties
$960
Penalties on Record
$560
Site Address
115 Gulick Street, Blossburg, PA 16912
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling19 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Asbestos (all forms)10f/cc
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0021mg/m³
Cobalt, Metal, Dust and Fume (as Co)40 - 0.0053mg/m³
Copper Fume (as Cu)40 - 0.003mg/m³
Iron Oxide Fume40 - 0.6926mg/m³
Lead, Inorganic (as Pb)40 - 0.0084mg/m³
Magnesium Oxide Fume (Total Particulate)40 - 0.0138mg/m³
Manganese Fume (as Mn)40 - 0.1812mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Respirable Fraction)30mg/m³
Particulates not otherwise regulated (Total Dust)90.016 - 1.2mg/m³
Silica, Crystalline Cristobalite, Respirable Dust20%
Silica, Crystalline Quartz (Respirable Fraction)140 - 18mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40 - 0.0337mg/m³

Violations

Violation list (12 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious12$480$280Feb 13, 1990--
01001B1910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$0$0Feb 13, 1990--
01001C1910.1048
Formaldehyde
OSHA citation code: 19101048 I03
Serious11$0$0Feb 13, 1990--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 D02 II
Serious16$480$280Feb 13, 1990--
020011904.2
OSHA citation code: 19040002 A
Other11$0$0Feb 13, 1990--
020021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Other850$0$0Apr 29, 1990--
02003A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G05 I
Other44$0$0Mar 15, 1990--
02003B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Other44$0$0Mar 15, 1990--
02003C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 I
Other22$0$0Feb 28, 1990--
02003D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 IIB
Other22$0$0Feb 28, 1990--
02003E1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G08 IIC
Other22$0$0Feb 28, 1990--
020041910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Other1010$0$0Mar 15, 1990--

Showing the 12 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 16, 1989Complaint (B) · Partial scope, Safety#18223222$4,13042 viol.

Inspection #18223222

Dates

Opened
Oct 16, 1989
Closing Conference Date
Jan 24, 1990
Closed
Mar 28, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
658
Related Activity
2 complaints

Violations and Penalties

Total Violations
42
Violation Types
36 serious, 6 other-than-serious
Initial Penalties
$8,260
Penalties on Record
$4,130
Site Address
115 Gulick Street, Blossburg, PA 16912
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 42 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious12$210$105Feb 26, 1990--
010025A0001
General Duty Clause, Section 5(a)(1)
Serious11$210$105Feb 12, 1990--
01003A1910.23
OSHA citation code: 19100023 C01
Serious12$280$140Feb 12, 1990--
01003B1910.23
OSHA citation code: 19100023 C03
Serious12$0$0Feb 26, 1990--
010041910.27
OSHA citation code: 19100027 F
Serious12$210$105Feb 12, 1990--
010051910.94
Ventilation
OSHA citation code: 19100094 A07
Serious22$210$105Feb 12, 1990--
010061910.106
OSHA citation code: 19100106 E02 IVA
Serious42$210$105Mar 12, 1990--
01007A1910.106
OSHA citation code: 19100106 E06 I
Serious36$210$105Feb 12, 1990--
01007B1910.106
OSHA citation code: 19100106 E06 II
Serious11$0$0Feb 12, 1990--
01008A1910.106
OSHA citation code: 19100106 E09 IV
Serious12$350$175Feb 12, 1990--
01008B1910.106
OSHA citation code: 19100106 F06
Serious12$0$0Feb 12, 1990--
01008C1910.106
OSHA citation code: 19100106 G03 VIA
Serious12$0$0Mar 12, 1990--

Showing the 12 violations listed first by citation identifier. This inspection has 42 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 23, 1987Planned (H) · Partial scope, Safety#1993328$00 viol.

Inspection #1993328

Dates

Opened
Apr 23, 1987
Closing Conference Date
Apr 23, 1987
Closed
Apr 27, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
550

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
115 Gulick Street, Blossburg, PA 16912
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 21 to 24 of 24, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure13 citations · $2,460
1910.217Mechanical Power Presses9 citations · $2,340
1910.1067 citations · $385

Chemical exposure sampling

Samples
88
Substances
19
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer3.8
Industry average3.3
Penalties per inspection
This employer$2,030
Industry average$2,302

Fabricated Metal Product Manufacturing, 45,966 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in Blossburg, PA

All employers in Blossburg →