Mar 30, 1995#109166868Mar 30, 1995Planned (H) · Complete scope, Safety#109166868$2,43818 viol.18 violations$2,438 in penalties
Inspection #109166868
Dates
- Opened
- Mar 30, 1995
- Closing Conference Date
- Mar 30, 1995
- Closed
- Jun 9, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 175
Violations and Penalties
- Total Violations
- 18
- Violation Types
- 8 serious, 10 other-than-serious
- Initial Penalties
- $4,875
- Penalties on Record
- $2,438
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 18 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Serious | 3 | 16 | $1,500 | $750 | Jun 9, 1995 | - | - |
| 01001B | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 2 | $0 | $0 | Jun 9, 1995 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $1,875 | $938 | Jun 9, 1995 | - | - |
| 01003A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 2 | 12 | $1,500 | $750 | Jun 9, 1995 | - | - |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A01 I | Serious | 1 | 5 | $0 | $0 | Jun 9, 1995 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 20, 1990#107055881Apr 20, 1990Follow-Up (F) · Partial scope, Health#107055881$01 viol.1 violation$0 in penalties
Inspection #107055881
Dates
- Opened
- Apr 20, 1990
- Closing Conference Date
- Apr 25, 1990
- Closed
- Jul 24, 1990
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 140
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 11 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 10 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 11 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 11 | 0 - 0.3765 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 11 | 0 | mg/m³ |
| Copper Dusts and Mists (as Cu) | 2 | 0.0289 - 0.0484 | mg/m³ |
| Copper Fume (as Cu) | 9 | 0 - 0.115 | mg/m³ |
| Iron Oxide Fume | 11 | 0 - 2.0841 | mg/m³ |
| Lead, Inorganic (as Pb) | 11 | 0 - 0.0128 | mg/m³ |
| Manganese Fume (as Mn) | 11 | 0 - 0.0509 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 11 | 0 - 0.1028 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 11 | 0 - 0.3686 | mg/m³ |
| Vanadium fume (as V2O5) | 11 | 0 - 0.0035 | mg/m³ |
| Zinc Oxide Fume | 11 | 0 - 0.0417 | mg/m³ |
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1025 Lead OSHA citation code: 19101025 L02 I | Other | 2 | 10 | $0 | $0 | Aug 6, 1990 | - | - |
Jan 2, 1990#107055840Jan 2, 1990Monitoring (D) · Partial scope, Health#107055840$00 viol.0 violations$0 in penalties
Inspection #107055840
Dates
- Opened
- Jan 2, 1990
- Closing Conference Date
- Jan 3, 1990
- Closed
- Jan 3, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 140
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 8 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 7 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 8 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 8 | 0 - 0.162 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 8 | 0 | mg/m³ |
| Copper Fume (as Cu) | 8 | 0 - 0.1901 | mg/m³ |
| Iron Oxide Fume | 8 | 0 - 1.0943 | mg/m³ |
| Lead, Inorganic (as Pb) | 8 | 0 - 0.0142 | mg/m³ |
| Manganese Fume (as Mn) | 8 | 0 - 0.0611 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 8 | 0 - 0.0633 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 8 | 0 - 0.2921 | mg/m³ |
| Vanadium fume (as V2O5) | 8 | 0 - 0.0022 | mg/m³ |
| Zinc Oxide Fume | 8 | 0 - 0.1519 | mg/m³ |
Jul 6, 1988#102921467Jul 6, 1988Complaint (B) · Partial scope, Health#102921467$2883 viol.3 violations$288 in penalties
Inspection #102921467
Dates
- Opened
- Jul 6, 1988
- Closing Conference Date
- Oct 7, 1988
- Closed
- Apr 7, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 140
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 repeat
- Initial Penalties
- $360
- Penalties on Record
- $288
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 8 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 8 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 8 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 8 | 0 - 0.3252 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 8 | 0 | mg/m³ |
| Copper Fume (as Cu) | 8 | 0 - 0.2128 | mg/m³ |
| Iron Oxide Fume | 8 | 0 - 0.9758 | mg/m³ |
| Lead, Inorganic (as Pb) | 8 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 8 | 0 - 0.1635 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 8 | 0 - 0.0301 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 8 | 0 - 0.1898 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 6 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 8 | 0 - 0.003 | mg/m³ |
| Zinc Oxide Fume | 8 | 0 - 0.0185 | mg/m³ |
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 C | Repeat | 2 | 2 | $360 | $288 | Nov 25, 1988 | - | - |
| 01001B | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Repeat | 2 | 2 | $0 | $0 | Mar 31, 1990 | - | - |
| 01001C | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Repeat | 2 | 2 | $0 | $0 | Mar 31, 1990 | - | - |
Aug 27, 1987#100536127Aug 27, 1987Follow-Up (F) · Partial scope, Health#100536127$00 viol.0 violations$0 in penalties
Inspection #100536127
Dates
- Opened
- Aug 27, 1987
- Closing Conference Date
- Oct 1, 1987
- Closed
- Oct 1, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 125
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 4 | 0 - 0.221 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 4 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 4 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 4 | 0 - 0.8821 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 4 | 0 | mg/m³ |
| Copper Fume (as Cu) | 4 | 0 - 1.9839 | mg/m³ |
| Iron Oxide Fume | 4 | 0 - 6.4948 | mg/m³ |
| Lead, Inorganic (as Pb) | 4 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 4 | 0 - 0.0425 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 4 | 0 - 0.0343 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 4 | 0 - 1.0397 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 4 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 4 | 0 | mg/m³ |
| Zinc Oxide Fume | 4 | 0 - 0.0064 | mg/m³ |
Mar 5, 1987#102856218Mar 5, 1987Monitoring (D) · Partial scope, Health#102856218$00 viol.0 violations$0 in penalties
Inspection #102856218
Dates
- Opened
- Mar 5, 1987
- Closing Conference Date
- Mar 5, 1987
- Closed
- Mar 5, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 115
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Aug 28, 1986#100470707Aug 28, 1986Monitoring (D) · Partial scope, Health#100470707$00 viol.0 violations$0 in penalties
Inspection #100470707
Dates
- Opened
- Aug 28, 1986
- Closing Conference Date
- Aug 28, 1986
- Closed
- Aug 28, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 115
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Mar 6, 1986#100470640Mar 6, 1986Monitoring (D) · Partial scope, Health#100470640$00 viol.0 violations$0 in penalties
Inspection #100470640
Dates
- Opened
- Mar 6, 1986
- Closing Conference Date
- Mar 6, 1986
- Closed
- Mar 6, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 136
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Jan 31, 1985#924985Jan 31, 1985Planned (H) · Complete scope, Health#924985$3605 viol.5 violations$360 in penalties
Inspection #924985
Dates
- Opened
- Jan 31, 1985
- Closing Conference Date
- May 24, 1985
- Closed
- Oct 23, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 136
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $360
- Penalties on Record
- $360
- Site Address
- 205 Wood Road, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling16 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 17 | 0 - 0.0402 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 17 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 17 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 17 | 0.0134 - 2.6285 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 17 | 0 - 0.0142 | mg/m³ |
| Copper Fume (as Cu) | 17 | 0.028 - 8.5133 | mg/m³ |
| Iron Oxide Fume | 17 | 0.3308 - 19.7931 | mg/m³ |
| Lead, Inorganic (as Pb) | 17 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 17 | 0.0453 - 1.0297 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 17 | 0 - 0.4118 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 17 | 0.0075 - 2.0384 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 18 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 4 | 0.247 - 0.802 | mg/m³ |
| Silica, Crystalline Quartz (Respirable Fraction) | 4 | 7.2 - 10 | % |
| Vanadium fume (as V2O5) | 17 | 0 - 0.0166 | mg/m³ |
| Zinc Oxide Fume | 17 | 0.0146 - 0.0593 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | 21 | $360 | $360 | Sep 30, 1985 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 C | Serious | 1 | 1 | $0 | $0 | Sep 30, 1985 | - | - |
| 01001C | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 1 | 1 | $0 | $0 | Mar 10, 1986 | - | - |
| 01001D | 1910.1000 Air Contaminants OSHA citation code: 19101000 C | Serious | 1 | 2 | $0 | $0 | Sep 30, 1985 | - | - |
| 01001E | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 14 | 14 | $0 | $0 | May 31, 1987 | - | - |
Mar 12, 1982#10023406Mar 12, 1982Planned (H) · Partial scope, Safety#10023406$04 viol.4 violations$0 in penalties
Inspection #10023406
Dates
- Opened
- Mar 12, 1982
- Closing Conference Date
- Mar 12, 1982
- Contested
- Apr 15, 1982
- Closed
- Dec 14, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 144
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 205 Wood Rd, Braintree, MA 02184
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 B05 | Other | 1 | - | $0 | $0 | Apr 12, 1982 | Apr 15, 1982 | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 2 | - | $0 | $0 | Apr 12, 1982 | Apr 15, 1982 | - |
| 01003 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 2 | - | $0 | $0 | May 3, 1982 | Apr 15, 1982 | - |
| 01004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Other | 1 | - | $0 | $0 | Apr 5, 1982 | Apr 15, 1982 | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
37 inspections, 1973 to 2026. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.