Skip to content
SafetyRecord logoSafetyRecord

Shell Opus Puget Sound Refinery

8505 S TEXAS RD, ANACORTES, WA 98221 · County SKAGIT · FRS ID 110008214360

EPA programs: Clean Air Act (Major Emissions), Clean Water Act (Major, Non-M), RCRA (LQG), Toxics Release Inventory, Greenhouse Gas Reporting · NAICS 221112, 221119, 32411, 324110 · EPA active-permit flag: Y

What EPA's files show for this facility

Inspections and evaluations
12
5 years, CAA, CWA and RCRA · last Apr 23, 2026
Formal enforcement actions
7
5 years · last Dec 19, 2025
Penalties
$80,128
5 years, 5 penalties, program databases
Compliance status
Significant Violation
EPA's current status, highest priority across programs
Federal enforcement cases
8
EPA ICIS FE&C, all years · newest Dec 30, 2020

EPA ECHO Exporter file of Nov 15, 2026; federal case file of Nov 14, 2026. The two files have different scopes and are never added together. EPA: these determinations "do not necessarily represent a final adjudication by a judicial or administrative body. In such cases, these characterizations should be considered alleged violations" (ECHO data dictionary). Having EPA enforcement records is common for facilities in regulated industries. Data and methodology

Five-year summary by program

ProgramInspectionsInformal actionsFormal actionsPenaltiesLast penaltyCompliance status
Clean Air ActWANCA0005305700003254$77,128$21,000 on Oct 2, 2024No Violation Identified
Clean Water ActWA0002941 WAR303256922$3,000$2,000 on Feb 18, 2025Violation Identified
RCRA hazardous wasteWAD009276197111$0$3,000 on Feb 7, 1991Significant Noncomplier

Counts cover the last five years, which EPA defines as "the 20 most recently completed quarters, plus data from the current quarter up until the refresh date" for inspections. Penalties are those entered in EPA's program databases; federal penalties entered in ICIS are left out by EPA "to avoid duplicative counting" and appear under federal enforcement cases instead. "Last penalty" is EPA's last-penalty field and can be older than five years. EPA's file has no inspection or penalty columns for the Safe Drinking Water Act. Compliance status is EPA's term, and EPA's note above applies: these characterizations "should be considered alleged violations".

Federal enforcement cases, all years

EPA ICIS FE&C, file of Nov 14, 2026 · federal cases only

Cases naming this facility8
Newest case statusDec 30, 2020
Oldest caseFY 1986
LawsCAA, EPCRA, RCRA
CaseLawTypeStatusOutcomeFederal penalty assessed or agreed toState or local penaltySEP valueCompliance action cost
10-2021-0003FY 2021CAAAdministrative - FormalFinal Order IssuedDec 30, 2020Final Order With Penalty$191,514$0$0$20,255
EF-2015-8069FY 2015 · names 10 facilities with an FRS IDCAAAdministrative - FormalClosedFeb 13, 2015Default Order With Penalty$900,000$0$0$0
10-2010-0193FY 2010CAAJudicialClosedOct 27, 2009Final Order No Penalty$0$0$0$0
WF-2003-2018FY 2003 · names 24 facilities with an FRS IDCAAAdministrative - FormalFinal Order IssuedSep 27, 2006Not recorded$600,000$0$0$0
10-2004-0147FY 2004EPCRAAdministrative - FormalClosedMay 18, 2004Final Order With Penalty$5,000$0$0$0
10-2001-0256FY 2001Not recordedJudicialConcludedAug 21, 2001Combined With Another Case(s)Not recordedNot tracked before 2002Not recordedNot recorded
06-2000-1232FY 2000 · names 9 facilities with an FRS IDCAAJudicialFinal Order EnteredAug 20, 2001Final Order With Penalty$4,400,000$5,100,000$0$399,999,999.99
10-1986-0023FY 1986RCRAAdministrative - FormalClosedAug 6, 1985Source Agrees$0Not tracked before 2002$0$0

8 federal cases name this facility. Amounts are for the whole case as EPA records them (EF-2015-8069 names 10 facilities with an FRS ID; WF-2003-2018 names 24 facilities with an FRS ID; 06-2000-1232 names 9 facilities with an FRS ID), never split between facilities or added up. EPA: SEP and compliance action costs are estimates and "are not fines paid to EPA"; state and local penalties were not tracked before 2002; ICIS "may contain duplicates of actions and penalties shown in the program databases"; and "there may be a delay of up to several months" before concluded cases are entered (FE&C download summary). Case numbers open EPA's case report.

Sources. U.S. Environmental Protection Agency, ECHO Exporter and ICIS FE&C case downloads, published weekly at echo.epa.gov. The full EPA record: EPA Detailed Facility Report for FRS ID 110008214360.

These are EPA records, reproduced as published. Dates before 1970 or after EPA's file date are kept as EPA publishes them and marked "Not shown". SafetyRecord.org is not a consumer reporting agency. EPA ECHO Exporter file of Nov 15, 2026. Data and methodology