Skip to content
SafetyRecord logoSafetyRecord

Inspection #100423144

Closed

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a referral inspection of WESTERN WALL SYSTEMS, LTD. at Drexel Univ. Dormitory - 34th & Arch Streets, Philadelphia, PA 19104 on Apr 23, 1986. The inspection scope was complete. The case was closed on Oct 27, 1989.

OSHA documented 17 violations (13 serious, 4 other-than-serious) with total penalties on record of $6,160. This inspection is linked to 1 referral in OSHA records.

This employer has 1 other OSHA inspection on record at this establishment.

Inspection Details

Inspection Number
100423144
Type
Referral (C)
Scope
Complete
Opened
Apr 23, 1986
Closed
Oct 27, 1989
Total Violations
17
Penalties on Record
$6,160
Initial Penalties
$6,160
Related Activity
1 referral
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Establishment

Address
Drexel Univ. Dormitory - 34th & Arch Streets, Philadelphia, PA 19104
Industry
238310 Drywall and Insulation Contractors

Other Inspections of This Employer1 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Oct 27, 1989.

Citations on Record
17

13 serious, 4 other-than-serious.

Initial Penalties
$6,160

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$6,160

Current and initial penalty totals are the same on record.

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010011926.20
General Safety and Health Provisions
OSHA citation code: 19260020 B01
Serious$560$560Oct 8, 1986--
010021926.25
Housekeeping
OSHA citation code: 19260025 A
Serious$320$320Sep 19, 1986--
010031926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious$480$480Sep 19, 1986--
010041926.250
General Requirements for Storage
OSHA citation code: 19260250 B01
Serious$400$400Sep 19, 1986--
010051926.350
Gas Welding and Cutting
OSHA citation code: 19260350 J
Serious$560$560Sep 18, 1986--
010061926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A
Serious$480$480Sep 19, 1986--
010071926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A
Serious$480$480Sep 19, 1986--
010081926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 A
Serious$480$480Sep 19, 1986--
010091926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 H01
Serious$480$480Sep 19, 1986--
010101926.402
Applicability (Electrical - Construction)
OSHA citation code: 19260402 A05
Serious$480$480Sep 19, 1986--
010111926.402
Applicability (Electrical - Construction)
OSHA citation code: 19260402 A11
Serious$320$320Sep 18, 1986--
010121926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 D01
Serious$480$480Sep 19, 1986--
010131926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B02 I
Serious$480$480Sep 19, 1986--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other$80$80Sep 19, 1986--
020021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 B02
Other$80$80Sep 18, 1986--
020031926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other$0$0Sep 18, 1986--
020041926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 C15
Other$0$0Sep 19, 1986--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.