Skip to content
SafetyRecord logoSafetyRecord
GOLDEN GIANT INC
$950
penalties
83
viol.
6
insp.

GOLDEN GIANT INC

400 EAST DECATUR ST, Kenton, OH 43326NAICS 332311 Prefabricated Metal Building and Component Manufacturing

Inspections
6
Sep 1974 to Nov 1986 · 5 safety, 1 health
Violations
83
across 6 inspections
Penalties on record
$950
latest amounts in DOL records
By classification
Serious 17Willful 0Repeat 3Other 63

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 20, 1986Referral (C) · Partial scope, Health#101654630$01 viol.

Inspection #101654630

Dates

Opened
Nov 20, 1986
Closing Conference Date
Dec 22, 1986
Closed
Jan 7, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
400 Decatur Avenue, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling18 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0174mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40 - 0.0198mg/m³
Iron Oxide Fume40 - 2.9274mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40 - 0.3241mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Respirable Fraction)50.161mg/m³
Petroleum Distillates (Naphtha) (Rubber Solvent)182mg/m³
Silica, Crystalline Quartz (Respirable Fraction)10
Toluene152.5ppm
Vanadium fume (as V2O5)40mg/m³
Xylene13.3ppm
Zinc Oxide Fume40 - 0.0295mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 D02
Other12$0$0Jan 12, 1987--
Oct 22, 1986Planned (H) · Complete scope, Safety#101654531$55041 viol.

Inspection #101654531

Dates

Opened
Oct 22, 1986
Closing Conference Date
Oct 29, 1986
Contested
Dec 17, 1986
Closed
May 21, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
41
Violation Types
16 serious, 25 other-than-serious
Initial Penalties
$1,140
Penalties on Record
$550
Site Address
400 Decatur Avenue, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Dec 17, 1986. Final orders are recorded through Apr 25, 1987. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (8 of 41 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
Ladders
OSHA citation code: 19100023 C01
Serious12$180$55Dec 26, 1986Dec 17, 1986Apr 25, 1987
01001B1910.23
Ladders
OSHA citation code: 19100023 D01 I
Serious12$0$0Dec 26, 1986--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious12$60$55Jan 14, 1987Dec 17, 1986Apr 25, 1987
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious12$0$0Dec 26, 1986--
01002C1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Serious12$0$0Dec 2, 1986--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$60$55Nov 27, 1986Dec 17, 1986Apr 25, 1987
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$120$55Dec 26, 1986Dec 17, 1986Apr 25, 1987
01005A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious12$120$55Dec 26, 1986Dec 17, 1986Apr 25, 1987

Showing the 8 violations listed first by citation identifier. This inspection has 41 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 18, 1977Complaint (B) · Partial scope, Safety#14539365$3004 viol.

Inspection #14539365

Dates

Opened
Oct 18, 1977
Closing Conference Date
Oct 18, 1977
Contested
Nov 15, 1977
Closed
Jan 14, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
35
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 repeat
Initial Penalties
$1,470
Penalties on Record
$300
Site Address
400 East Decatur St, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious1-$210$0Dec 7, 1977Nov 15, 1977-
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat1-$420$100Nov 10, 1977Nov 15, 1977-
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Repeat1-$420$100Dec 6, 1977Nov 15, 1977-
020031910.309
OSHA citation code: 19100309 A 011017
Repeat1-$420$100Nov 10, 1977Nov 15, 1977-
Jul 7, 1975Follow-Up (F) · Complete scope, Safety#214588733$00 viol.

Inspection #214588733

Dates

Opened
Jul 7, 1975
Closing Conference Date
Jul 7, 1975
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
400 Decatur Street, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 21, 1975Follow-Up (F) · Complete scope, Safety#214588311$505 viol.

Inspection #214588311

Dates

Opened
Apr 21, 1975
Closing Conference Date
Apr 21, 1975
Closed
Jun 2, 1975

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$50
Penalties on Record
$50
Site Address
400 Decatur Street, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.309
OSHA citation code: 19100309 A 011017
Other1-$0$0Jun 6, 1975--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Other1-$0$0Jun 6, 1975--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other1-$0$0Jun 6, 1975--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Other1-$25$25Jun 6, 1975--
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other1-$25$25Jun 6, 1975--
Sep 9, 1974Planned (H) · Complete scope, Safety#214587016$5032 viol.

Inspection #214587016

Dates

Opened
Sep 9, 1974
Closing Conference Date
Sep 9, 1974
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
45

Violations and Penalties

Total Violations
32
Violation Types
32 other-than-serious
Initial Penalties
$50
Penalties on Record
$50
Site Address
400 Decatur Street, Kenton, OH 43326
Industry
332311 Prefabricated Metal Building and Component Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 32 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01 I
Other2-$0$0Nov 4, 1974--
010021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other2-$0$0Nov 4, 1974--
010031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D02 I
Other1-$0$0Oct 10, 1974--
010041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D03 I
Other1-$0$0Nov 4, 1974--
010051910.106
Flammable Liquids
OSHA citation code: 19100106 D07 III
Other1-$0$0Nov 4, 1974--
010061910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other3-$0$0Dec 19, 1974--
010071910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q05
Other1-$0$0Nov 4, 1974--
010081910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Other1-$0$0Nov 4, 1974--

Showing the 8 violations listed first by citation identifier. This inspection has 32 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus10 citations · $25
1910.217Mechanical Power Presses8 citations · $165
1910.179Overhead and Gantry Cranes7 citations · $0

Chemical exposure sampling

Samples
59
Substances
18
Inspections
1

Industry comparison

Violations per inspection
This employer13.8
Industry average3.3
Penalties per inspection
This employer$158
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.