Skip to content
SafetyRecord logoSafetyRecord
SIGNGRAPHICS, INC.
$1,470
penalties
25
viol.
2
insp.

SIGNGRAPHICS, INC.

10011 MILLER RD., DALLAS, TX 75238

Inspections
2
Apr 1986 to Jun 1986 · 1 safety, 1 health
Violations
25
across 2 inspections
Penalties on record
$1,470
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 20

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 2, 1986Referral (C) · Partial scope, Health#101786044$03 viol.

Inspection #101786044

Dates

Opened
Jun 2, 1986
Closing Conference Date
Jun 3, 1986
Closed
Oct 6, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
10011 Miller Rd., Dallas, TX 75238
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)70mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Cadmium Fume (as Cd)70mg/m³
Chromium, Metal and Insoluble Salts70 - 0.0146mg/m³
Cobalt, Metal, Dust and Fume (as Co)70mg/m³
Copper Fume (as Cu)70mg/m³
Iron Oxide Fume70 - 0.2216mg/m³
Lead, Inorganic (as Pb)70 - 0.0157mg/m³
Manganese Fume (as Mn)70 - 0.0061mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)70mg/m³
Nickel, Metal and Insoluble compounds (as Ni)70mg/m³
Particulates not otherwise regulated (Respirable Fraction)70mg/m³
Vanadium fume (as V2O5)70mg/m³
Zinc Oxide Fume70 - 0.0968mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 D02
Other13$0$0Aug 19, 1986--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other14$0$0Aug 19, 1986--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other14$0$0Aug 19, 1986--
Apr 22, 1986Planned (H) · Complete scope, Safety#101788560$1,47022 viol.

Inspection #101788560

Dates

Opened
Apr 22, 1986
Closing Conference Date
Apr 24, 1986
Closed
Oct 10, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75

Violations and Penalties

Total Violations
22
Violation Types
5 serious, 17 other-than-serious
Initial Penalties
$1,470
Penalties on Record
$1,470
Site Address
10011 Miller Rd., Dallas, TX 75248
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (22 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 A12
Serious16$210$210Jul 14, 1986--
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious16$280$280Jul 14, 1986--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01
Serious110$350$350Jul 14, 1986--
010041910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious11$350$350Jul 14, 1986--
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious44$280$280Jul 14, 1986--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other15$0$0Jul 9, 1986--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other22$0$0Jul 21, 1986--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Other22$0$0Jul 14, 1986--
020041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B06
Other22$0$0Jul 14, 1986--
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Other12$0$0Jul 14, 1986--
020061910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other12$0$0Jul 14, 1986--
020071910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Other12$0$0Jul 14, 1986--
020081910.134
Respiratory Protection
OSHA citation code: 19100134 B05
Other12$0$0Jul 14, 1986--
020091910.134
Respiratory Protection
OSHA citation code: 19100134 B06
Other12$0$0Jul 14, 1986--
020101910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Other12$0$0Jul 14, 1986--
020111910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H03
Other16$0$0Jul 14, 1986--
020121910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Other16$0$0Jul 14, 1986--
020131910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other110$0$0Jul 14, 1986--
020141910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0Jul 9, 1986--
020151910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other12$0$0Jul 9, 1986--
020161910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other22$0$0Jul 14, 1986--
020171910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Other22$0$0Jul 14, 1986--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection5 citations · $0
1910.213Woodworking Machinery Requirements4 citations · $490
1910.107Spray Finishing Using Flammable and Combustible Materials4 citations · $0

Chemical exposure sampling

Samples
97
Substances
14
Inspections
1

Other inspected employers in DALLAS, TX

All employers in DALLAS →