Oct 11, 1991#107573578Oct 11, 1991Referral (C) · Partial scope, Safety#107573578$00 viol.0 violations$0 in penalties
Inspection #107573578
Dates
- Opened
- Oct 11, 1991
- Closing Conference Date
- Oct 11, 1991
- Closed
- Oct 11, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 100
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1012 Stanhouse Blvd., Magnolia, AR 71753
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Jul 17, 1991#106786908Jul 17, 1991Complaint (B) · Partial scope, Health#106786908$2,0006 viol.6 violations$2,000 in penalties
Inspection #106786908
Dates
- Opened
- Jul 17, 1991
- Closing Conference Date
- Sep 12, 1991
- Closed
- Dec 18, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 105
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $4,000
- Penalties on Record
- $2,000
- Site Address
- 1012 Stanhouse Blvd., Magnolia, AR 71753
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Formaldehyde | 6 | 0.2779 - 1.2012 | ppm |
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1048 Formaldehyde OSHA citation code: 19101048 D02 II | Other | 1 | 10 | $1,200 | $0 | Oct 24, 1991 | - | - |
| 01001B | 1910.1048 Formaldehyde OSHA citation code: 19101048 D03 II | Serious | 1 | 11 | $0 | $0 | Oct 24, 1991 | - | - |
| 01002A | 1910.1048 Formaldehyde OSHA citation code: 19101048 H01 I | Serious | 1 | 10 | $1,200 | $800 | Nov 25, 1991 | - | - |
| 01002B | 1910.1048 Formaldehyde OSHA citation code: 19101048 H01 III | Serious | 1 | 10 | $0 | $0 | Nov 7, 1991 | - | - |
| 01003 | 1910.1048 Formaldehyde OSHA citation code: 19101048 I03 | Serious | 1 | 11 | $1,600 | $1,200 | Nov 7, 1991 | - | - |
| 02001 | 1910.1048 Formaldehyde OSHA citation code: 19101048 H02 II | Other | 1 | 11 | $0 | $0 | Oct 31, 1991 | - | - |
Dec 14, 1989#106573777Dec 14, 1989Planned (H) · Complete scope, Safety#106573777$1,49014 viol.14 violations$1,490 in penalties
Inspection #106573777
Dates
- Opened
- Dec 14, 1989
- Closing Conference Date
- Dec 14, 1989
- Closed
- Apr 17, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 105
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 12 serious, 2 other-than-serious
- Initial Penalties
- $3,440
- Penalties on Record
- $1,490
- Site Address
- 1012 Stanhouse Blvd., Magnolia, AR 71753
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | 1 | $320 | $0 | Feb 14, 1990 | - | - |
| 01002 | 1910.24 Step Bolts and Manhole Steps OSHA citation code: 19100024 H | Serious | 3 | 4 | $320 | $160 | Feb 14, 1990 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 2 | $320 | $160 | Mar 14, 1990 | - | - |
| 01004 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 A09 | Serious | 4 | 10 | $480 | $240 | Apr 14, 1990 | - | - |
| 01005A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | 2 | $320 | $160 | Mar 14, 1990 | - | - |
| 01005B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | 4 | $0 | $0 | Feb 14, 1990 | - | - |
| 01005C | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H03 | Serious | 1 | 4 | $0 | $0 | Feb 14, 1990 | - | - |
| 01006 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 R04 | Serious | 1 | 1 | $400 | $200 | Mar 14, 1990 | - | - |
| 01007A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 2 | $320 | $130 | Mar 14, 1990 | - | - |
| 01007B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 II | Serious | 2 | 2 | $0 | $0 | Feb 14, 1990 | - | - |
| 01007C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E05 I | Serious | 1 | 1 | $0 | $0 | Feb 14, 1990 | - | - |
| 01008 | 1910.243 Guarding of Portable Powered Tools OSHA citation code: 19100243 A01 I | Serious | 2 | 3 | $480 | $240 | Feb 14, 1990 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 25, 1987#103251534Mar 25, 1987Planned (H) · Complete scope, Safety#103251534$60017 viol.17 violations$600 in penalties
Inspection #103251534
Dates
- Opened
- Mar 25, 1987
- Closing Conference Date
- Mar 26, 1987
- Contested
- May 18, 1987
- Closed
- Oct 9, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 80
Violations and Penalties
- Total Violations
- 17
- Violation Types
- 3 serious, 14 other-than-serious
- Initial Penalties
- $600
- Penalties on Record
- $600
- Site Address
- Shanhouse Blvd., Magnolia, AR 71753
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Enforcement Outcome
Citation contest activity appears on May 18, 1987. Final orders are recorded through Oct 8, 1987. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Violations
Violation list (12 of 17 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | 1 | $100 | $100 | May 4, 1987 | May 18, 1987 | Oct 8, 1987 |
| 01002 | 1910.243 Guarding of Portable Powered Tools OSHA citation code: 19100243 C01 | Serious | 2 | 2 | $150 | $150 | May 19, 1987 | May 18, 1987 | Oct 8, 1987 |
| 01003 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Serious | 2 | 2 | $350 | $350 | May 4, 1987 | May 18, 1987 | Oct 8, 1987 |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A02 | Other | 1 | 20 | $0 | $0 | May 19, 1987 | - | - |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Other | 1 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02003 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 G01 V | Other | 2 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02004 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C03 | Other | 1 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02005 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Other | 1 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02006 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 2 | 2 | $0 | $0 | May 19, 1987 | - | - |
| 02007 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A02 IVC | Other | 1 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02008 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 B04 IXC | Other | 1 | 1 | $0 | $0 | May 19, 1987 | - | - |
| 02009 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 2 | 2 | $0 | $0 | May 19, 1987 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1987 to 1991. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.