Skip to content
SafetyRecord logoSafetyRecord
BOTTS WELDING AND TRUCK SERVICE, INCORPORATED
$5,140
penalties
29
viol.
4
insp.

BOTTS WELDING AND TRUCK SERVICE, INCORPORATED

335 NO. EASTWOOD DR., WOODSTOCK, IL 60098

Inspections
4
Jun 1988 to Jun 2013 · 1 safety, 3 health
Violations
29
across 4 inspections
Penalties on record
$5,140
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 0Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 12, 2013Planned (H) · Complete scope, Safety#339115719$3,6406 viol.

Inspection #339115719

Dates

Opened
Jun 12, 2013
Closing Conference Date
Jun 12, 2013
Final Order
Aug 16, 2013
Closed
Aug 16, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$5,200
Penalties on Record
$3,640
Site Address
335 N. Eastwood Dr., Woodstock, IL 60098
Industry
423120 Motor Vehicle Supplies and New Parts Merchant Wholesalers

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious32$2,000$1,400Sep 7, 2013-Aug 16, 2013
010021910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious13$1,200$840-Aug 16, 2013
010031910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 I
Serious12$2,000$1,400Sep 7, 2013-Aug 16, 2013
020011910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Other35$0$0-Aug 16, 2013
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other11$0$0-Aug 16, 2013
020031910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D09 III
Other11$0$0Aug 9, 2013-Aug 16, 2013
Jun 28, 1989Monitoring (D) · Partial scope, Health#102574498$00 viol.

Inspection #102574498

Dates

Opened
Jun 28, 1989
Closing Conference Date
Jun 28, 1989
Closed
Jun 28, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
335 No. Eastwood Dr., Woodstock, IL 60098
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Feb 28, 1989Complaint (B) · Complete scope, Health#103362018$1,50021 viol.

Inspection #103362018

Dates

Opened
Feb 28, 1989
Closing Conference Date
Apr 27, 1989
Closed
Jul 24, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28
Related Activity
1 complaint

Violations and Penalties

Total Violations
21
Violation Types
13 serious, 8 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$1,500
Site Address
335 No. Eastwood Drive, Woodstock, IL 60098
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious14$250$250Jun 25, 1989--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Serious11$300$300May 25, 1989--
01003A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Serious13$400$400May 25, 1989--
01003B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious13$0$0May 25, 1989--
01003C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 III
Serious13$0$0May 25, 1989--
01003D1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious13$0$0May 25, 1989--
01003E1910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious13$0$0May 25, 1989--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious13$250$250May 25, 1989--
01005A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious11$300$300May 25, 1989--
01005B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious13$0$0May 25, 1989--
01005C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 I
Serious13$0$0May 25, 1989--
01005D1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A01
Serious11$0$0May 25, 1989--

Showing the 12 violations listed first by citation identifier. This inspection has 21 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 28, 1988Complaint (B) · Partial scope, Health#102575248$02 viol.

Inspection #102575248

Dates

Opened
Jun 28, 1988
Closing Conference Date
Jun 29, 1988
Closed
Sep 8, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
335 No. Eastwood Drive, Woodstock, IL 60098
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)50mg/m³
Cadmium Fume (as Cd)60mg/m³
Chromium, Metal and Insoluble Salts60 - 0.0024mg/m³
Cobalt, Metal, Dust and Fume (as Co)60mg/m³
Copper Fume (as Cu)60 - 0.0066mg/m³
Iron Oxide Fume60 - 5.8419mg/m³
Lead, Inorganic (as Pb)60mg/m³
Manganese Fume (as Mn)60 - 1.1159mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60mg/m³
Nickel, Metal and Insoluble compounds (as Ni)60mg/m³
Particulates not otherwise regulated (Respirable Fraction)60mg/m³
Vanadium fume (as V2O5)60 - 0.0081mg/m³
Zinc Oxide Fume60 - 0.0225mg/m³

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other128$0$0Aug 22, 1988--
020011910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B04 IXC
Other13$0$0Aug 12, 1988--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses5 citations · $400
1910.303Electrical - General Requirements4 citations · $300
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0

Chemical exposure sampling

Samples
83
Substances
14
Inspections
1

Industry comparison

BLS 2024 survey: motor vehicle and motor vehicle parts and supplies merchant wholesalers reported 2.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.1%; NAICS 4231 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in WOODSTOCK, IL

All employers in WOODSTOCK →