CLARKLIFT OF WISCONSIN INC.
$960
penalties
14
viol.
2
insp.

CLARKLIFT OF WISCONSIN INC.

4500 N. 119TH, MILWAUKEE, WI 53225

Inspections
2
May 1988 to May 1989 · 0 safety, 2 health
Violations
14
across 2 inspections
Penalties on record
$960
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 10, 1989Monitoring (D) · Partial scope, Health#103314324$00 viol.

Inspection #103314324

Dates

Opened
May 10, 1989
Closing Conference Date
May 15, 1989
Closed
Jul 6, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
129

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4500 N. 119th, Milwaukee, WI 53225
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium Fume (as Cd)30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30 - 0.0832mg/m³
Iron Oxide Fume30 - 7.4407mg/m³
Lead, Inorganic (as Pb)30 - 0.0198mg/m³
Manganese Fume (as Mn)30 - 0.162mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Particulates not otherwise regulated (Respirable Fraction)20mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30 - 0.0098mg/m³
May 3, 1988Complaint (B) · Partial scope, Health#103467775$96014 viol.

Inspection #103467775

Dates

Opened
May 3, 1988
Closing Conference Date
Jun 1, 1988
Closed
Jul 28, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
129
Related Activity
1 complaint

Violations and Penalties

Total Violations
14
Violation Types
6 serious, 8 other-than-serious
Initial Penalties
$960
Penalties on Record
$960
Site Address
4500 N. 119th, Milwaukee, WI 53225
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)52P / 3A0mg/m³
Beryllium and Beryllium Compounds (as Be)42P / 2A0mg/m³
Cadmium Fume (as Cd)52P / 3A0mg/m³
Chromium, Metal and Insoluble Salts52P / 3A0 - 0.0087mg/m³
Cobalt, Metal, Dust and Fume (as Co)52P / 3A0 - 0.017mg/m³
Copper Fume (as Cu)52P / 3A0 - 0.2306mg/m³
Iron Oxide Fume52P / 3A0 - 16.4412mg/m³
Lead, Inorganic (as Pb)52P / 3A0 - 0.0659mg/m³
Manganese Fume (as Mn)52P / 3A0 - 0.5775mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)52P / 3A0mg/m³
Nickel, Metal and Insoluble compounds (as Ni)52P / 3A0 - 0.0066mg/m³
Particulates not otherwise regulated (Respirable Fraction)42P / 2A0mg/m³
Vanadium fume (as V2O5)52P / 3A0mg/m³
Zinc Oxide Fume52P / 3A0 - 0.0299mg/m³

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other160$0$0Jun 20, 1988--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other160$0$0Jul 5, 1988--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other160$0$0Jul 5, 1988--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other160$0$0May 31, 1988--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other160$0$0May 31, 1988--
010061910.1025
Lead
OSHA citation code: 19101025 D02
Other11$0$0Jun 20, 1988--
02001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$480$480Jul 13, 1988--
02001B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious11$0$0Jul 20, 1988--
02001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Mar 1, 1989--
02002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$480$480Jul 13, 1988--
02002B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious11$0$0Jul 13, 1988--
02002C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Mar 1, 1989--
030011910.1025
Lead
OSHA citation code: 19101025 D02
Other11$0$0Jun 24, 1988--
030021910.1025
Lead
OSHA citation code: 19101025 L01 II
Other11$0$0Jul 20, 1988--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1000Air Contaminants4 citations · $0
1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0
1910.1025Lead3 citations · $0

Chemical exposure sampling

Samples
109
Substances
14
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in MILWAUKEE, WI

All employers in MILWAUKEE →