Skip to content
SafetyRecord logoSafetyRecord
CUMMINS-HART CONSTRUCTION CORPORATION
$2,802
penalties
13
viol.
4
insp.

CUMMINS-HART CONSTRUCTION CORPORATION

EUTAW & LEE STREETS, BALTIMORE, MD 21230

Inspections
4
May 1987 to Feb 1992 · 3 safety, 1 health
Violations
13
across 4 inspections
Penalties on record
$2,802
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 1Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 27, 1992Programmed Related (I) · Complete scope, Safety#104470075$2,1523 viol.

Inspection #104470075

Dates

Opened
Feb 27, 1992
Closing Conference Date
Mar 11, 1992
Closed
May 12, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$3,108
Penalties on Record
$2,152
Site Address
1910 Russell St, Baltimore, MD 21230
Industry
Not classified in OSHA's inspection record.

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious11$980$676Mar 3, 1992--
020011926.101
Hearing Protection
OSHA citation code: 19260101 A
Serious13$1,148$800Apr 23, 1992--
030011926.302
Power-Operated Hand Tools
OSHA citation code: 19260302 B01
Serious13$980$676Apr 23, 1992--
Feb 27, 1991Planned (H) · Complete scope, Safety#104354683$6504 viol.

Inspection #104354683

Dates

Opened
Feb 27, 1991
Closing Conference Date
Feb 27, 1991
Closed
Apr 16, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
11

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 repeat
Initial Penalties
$1,350
Penalties on Record
$650
Site Address
Eutaw & Lee Streets, Baltimore, MD 21230
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F 6
Repeat11$550$275Mar 24, 1991--
02001A1926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 F 1
Serious14$325$150Mar 24, 1991--
02001B1926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 D 2
Serious14$0$0Mar 24, 1991--
030011926.550
Cranes and Derricks
OSHA citation code: 19260550 B 2
Serious14$475$225Mar 24, 1991--
Nov 7, 1989Referral (C) · Partial scope, Health#104357884$05 viol.

Inspection #104357884

Dates

Opened
Nov 7, 1989
Closing Conference Date
Mar 1, 1990
Closed
Apr 27, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
3
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
5601 Eastern Avenue, Baltimore, MD 21224
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F 6
Other14$0$0Apr 2, 1990--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F 7 IVC
Other14$0$0Apr 2, 1990--
01003912.3304
OSHA citation code: 09123304 B
Other12$0$0Apr 2, 1990--
01004912.3204
OSHA citation code: 09123204 A 2 BI
Other12$0$0Apr 2, 1990--
01005912.3204
OSHA citation code: 09123204 B 2 AII
Other12$0$0Apr 2, 1990--
May 13, 1987Planned (H) · Complete scope, Safety#18835439$01 viol.

Inspection #18835439

Dates

Opened
May 13, 1987
Closing Conference Date
May 13, 1987
Closed
Jun 19, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
24

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Madison & Wolfe Sts., Baltimore, MD 21205
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B 1 II
Other12$0$0May 30, 1987--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)4 citations · $275
1926.500Fall Protection - Scope, Application, and Definitions2 citations · $150
912.32042 citations · $0

Other inspected employers in BALTIMORE, MD