Skip to content
SafetyRecord logoSafetyRecord
WILLOW CONSTRUCTION, INC.
$830
penalties
10
viol.
3
insp.

WILLOW CONSTRUCTION, INC.

CHESAPEAKE VILLAGE ROAD, QUEENSTOWN, MD 21658

Inspections
3
Apr 1989 to Oct 1990 · 3 safety, 0 health
Violations
10
across 3 inspections
Penalties on record
$830
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 1Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 1, 1990Planned (H) · Complete scope, Safety#104422753$7307 viol.

Inspection #104422753

Dates

Opened
Oct 1, 1990
Closing Conference Date
Oct 2, 1990
Contested
Nov 28, 1990
Closed
Dec 3, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 3 other-than-serious
Initial Penalties
$1,345
Penalties on Record
$730
Site Address
University Of Md, Cheston Lane, Queenstown, MD 21658
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Serious12$580$450Nov 5, 1990Nov 28, 1990-
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A14
Serious12$0$0Nov 5, 1990Nov 28, 1990-
02001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E 5
Serious12$0$0Nov 5, 1990Nov 28, 1990-
02001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E10
Serious12$0$0Nov 5, 1990Nov 28, 1990-
040021926.50
Medical Services and First Aid (Construction)
OSHA citation code: 19260050 D 1
Other112$280$280Nov 5, 1990Nov 28, 1990-
040031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D 3
Other12$205$0Nov 5, 1990Nov 28, 1990-
040041926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 B 8
Other312$280$0Nov 5, 1990Nov 28, 1990-
Feb 21, 1990Planned (H) · Complete scope, Safety#104355821$1002 viol.

Inspection #104355821

Dates

Opened
Feb 21, 1990
Closing Conference Date
Feb 23, 1990
Closed
Apr 9, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
2
Violation Types
1 repeat, 1 other-than-serious
Initial Penalties
$200
Penalties on Record
$100
Site Address
Chesapeake Village Road, Queenstown, MD 21658
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001890032
OSHA citation code: 890032 M B
Repeat13$200$100Mar 18, 1990--
02001890032
OSHA citation code: 890032 E C00002
Other13$0$0Mar 18, 1990--
Apr 17, 1989Planned (H) · Complete scope, Safety#104424270$01 viol.

Inspection #104424270

Dates

Opened
Apr 17, 1989
Closing Conference Date
Apr 17, 1989
Closed
Jun 21, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Us Rte. 50 & 301, Queenstown, MD 21658
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F 6
Other11$0$0Jun 2, 1989--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements5 citations · $450
8900322 citations · $100
1926.50Medical Services and First Aid (Construction)1 citation · $280

Other inspected employers in QUEENSTOWN, MD

All employers in QUEENSTOWN →