FULTON CONST., INC./COASTCON CORP. A JOINT VENTURE
5902 SARATOGA, CORPUS CHRISTI, TX 78414
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jun 21, 1995#103578928Jun 21, 1995Unprogrammed Related (G) · Partial scope, Safety#103578928$00 viol.0 violations$0 in penalties
Inspection #103578928
Dates
- Opened
- Jun 21, 1995
- Closing Conference Date
- Jun 22, 1995
- Closed
- Apr 5, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Ccnas, Corner Of Midway & Gettysburg, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Jun 13, 1995#103578787Jun 13, 1995Planned (H) · Complete scope, Safety#103578787$6253 viol.3 violations$625 in penalties
Inspection #103578787
Dates
- Opened
- Jun 13, 1995
- Closing Conference Date
- Jun 13, 1995
- Closed
- Aug 22, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 2 other-than-serious
- Initial Penalties
- $1,400
- Penalties on Record
- $625
- Site Address
- Ccnas, Corner Of Midway & Gettysburg, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.501 Fall Protection - Duty to Have Fall Protection OSHA citation code: 19260501 B01 | Serious | 2 | 1 | $875 | $525 | Aug 1, 1995 | - | - |
| 01001B | 1926.502 Fall Protection Systems Criteria and Practices OSHA citation code: 19260502 B01 | Other | 2 | 1 | $0 | $0 | Aug 1, 1995 | - | - |
| 01003 | 1926.602 Material Handling Equipment OSHA citation code: 19260602 A09 I | Other | 1 | 10 | $525 | $100 | Aug 1, 1995 | - | - |
May 17, 1995#122217185May 17, 1995Planned (H) · No Inspection scope, Safety#122217185$00 viol.0 violations$0 in penalties
Inspection #122217185
Dates
- Opened
- May 17, 1995
- Closing Conference Date
- May 17, 1995
- Closed
- Jun 19, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Ccnas, Corner Of Midway & Gettysburg, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 7, 1993#107433997Oct 7, 1993Planned (H) · Complete scope, Safety#107433997$2,31513 viol.13 violations$2,315 in penalties
Inspection #107433997
Dates
- Opened
- Oct 7, 1993
- Closing Conference Date
- Oct 20, 1993
- Closed
- Feb 4, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 53
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 5 serious, 1 repeat, 7 other-than-serious
- Initial Penalties
- $6,000
- Penalties on Record
- $2,315
- Site Address
- 5902 Saratoga, Corpus Christi, TX 78414
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.56 Illumination OSHA citation code: 19260056 A | Serious | 1 | 53 | $900 | $450 | Jan 4, 1994 | - | - |
| 01002A | 1926.59 Hazard Communication OSHA citation code: 19260059 F05 I | Other | 1 | 5 | $900 | $100 | Jan 4, 1994 | - | - |
| 01002B | 1926.152 Flammable Liquids OSHA citation code: 19260152 C03 | Other | 1 | 5 | $0 | $0 | Jan 4, 1994 | - | - |
| 01002C | 1926.152 Flammable Liquids OSHA citation code: 19260152 E04 | Other | 1 | 5 | $0 | $0 | Jan 4, 1994 | - | - |
| 01003A | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 B01 | Serious | 1 | 7 | $900 | $540 | Jan 4, 1994 | - | - |
| 01003B | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 B02 | Serious | 1 | 7 | $0 | $0 | Jan 4, 1994 | - | - |
| 01003C | 1926.416 Electrical - Safety Requirements (Construction) OSHA citation code: 19260416 E02 | Serious | 1 | 3 | $0 | $0 | Jan 4, 1994 | - | - |
| 01004 | 1926.500 Fall Protection - Scope, Application, and Definitions OSHA citation code: 19260500 D01 | Serious | 1 | 15 | $1,500 | $900 | Jan 4, 1994 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 30, 1993#107425654Apr 30, 1993Complaint (B) · No Inspection scope, Safety#107425654$00 viol.0 violations$0 in penalties
Inspection #107425654
Dates
- Opened
- Apr 30, 1993
- Closing Conference Date
- Apr 30, 1993
- Closed
- May 10, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 44
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 5902 Saratoga, Corpus Christi, TX 78414
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Nov 12, 1991#108760257Nov 12, 1991Planned (H) · Complete scope, Safety#108760257$6656 viol.6 violations$665 in penalties
Inspection #108760257
Dates
- Opened
- Nov 12, 1991
- Closing Conference Date
- Nov 13, 1991
- Closed
- Feb 24, 1992
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 3 serious, 1 repeat, 2 other-than-serious
- Initial Penalties
- $1,190
- Penalties on Record
- $665
- Site Address
- 1818 Trojan, Moody High School, Corpus Christi, TX 78416
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B02 | Serious | 3 | 11 | $1,050 | $525 | Dec 24, 1991 | - | - |
| 01001B | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 B01 | Serious | 2 | 11 | $0 | $0 | Dec 24, 1991 | - | - |
| 01001C | 1926.403 Electrical - General Requirements (Construction) OSHA citation code: 19260403 B01 | Serious | 3 | 11 | $0 | $0 | Dec 24, 1991 | - | - |
| 02001 | 1926.405 Electrical - Wiring Methods (Construction) OSHA citation code: 19260405 G02 IV | Repeat | 1 | 11 | $140 | $140 | Dec 24, 1991 | - | - |
| 03001A | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C01 | Other | 1 | 1 | $0 | $0 | Dec 21, 1991 | - | - |
| 03001B | 1926.1052 Stairways (Construction) OSHA citation code: 19261052 C04 | Other | 1 | 1 | $0 | $0 | Dec 21, 1991 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1991 to 1995. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.