Inspection #107448565
ClosedThis page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
The Occupational Safety and Health Administration (OSHA) conducted a complaint inspection of EARL SCHEIB AUTO PAINTING, INC. at 1130 Bay St., Springfield, MA 01109 on Dec 21, 1992. The inspection scope was partial. The case was closed on May 9, 1994.
OSHA documented 14 violations (12 serious, 2 repeat) with total penalties on record of $37,500. This inspection is linked to 1 complaint in OSHA records.
OSHA collected 4 air monitoring samples covering 4 substances during this inspection, including n-Butyl Acetate, n-Butyl Alcohol, Toluene, Xylene.
- Inspection Number
- 107448565
- Type
- Complaint (B)
- Scope
- Partial
- Opened
- Dec 21, 1992
- Closed
- May 9, 1994
- Contested
- Apr 13, 1993
- Final Order
- Apr 13, 1994
- Total Violations
- 14
- Penalties on Record
- $37,500
- Initial Penalties
- $75,000
- Related Activity
- 1 complaint
- Address
- 1130 Bay St., Springfield, MA 01109
- Industry
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.
Inspection closed May 9, 1994.
12 serious, 2 repeat.
Citation amounts as first recorded in OSHA's penalty fields.
Latest published amounts after changes in the enforcement process.
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| n-Butyl Acetate | 1 | 45.0439 | ppm |
| n-Butyl Alcohol | 1 | 6.8069 | ppm |
| Toluene | 1 | 27.8474 | ppm |
| Xylene | 1 | 6.5313 | ppm |
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
| Citation | Standard | Type | Initial | Current | Abatement |
|---|---|---|---|---|---|
| 01001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q01 | Serious | $1,500 | $750 | Apr 9, 1993 |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D04 IV | Serious | $1,500 | $750 | May 12, 1993 |
| 01003 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 D05 | Serious | $1,500 | $750 | May 12, 1993 |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | $2,500 | $1,250 | Apr 9, 1993 |
| 01005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | $2,000 | $1,000 | Apr 9, 1993 |
| 01006 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | $2,000 | $1,000 | Apr 1, 1993 |
| 01007 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Serious | $2,000 | $1,000 | Apr 9, 1993 |
| 01008 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Serious | $2,000 | $1,000 | Apr 9, 1993 |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Serious | $5,000 | $2,500 | May 12, 1993 |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D04 I | Serious | $7,500 | $3,750 | May 12, 1993 |
| 02003 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D04 III | Serious | $7,500 | $3,750 | May 12, 1993 |
| 02004 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Serious | $7,500 | $3,750 | May 12, 1993 |
| 02005 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Repeat | $15,000 | $7,500 | May 12, 1993 |
| 02006 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Repeat | $17,500 | $8,750 | Apr 9, 1993 |
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
Data Source and Methodology
Data synced dailyData on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.