Skip to content
SafetyRecord logoSafetyRecord
PRESTO CASTING COMPANY
$13,350
penalties
25
viol.
15
insp.

PRESTO CASTING COMPANY

5440 W. MISSOURI, GLENDALE, AZ 85301

Inspections
15
Mar 1983 to Jun 2009 · 9 safety, 6 health
Violations
25
across 15 inspections
Penalties on record
$13,350
latest amounts in DOL records
By classification
Serious 6Willful 1Repeat 0Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 29, 2009Referral (C) · Complete scope, Safety#313587685$00 viol.

Inspection #313587685

Dates

Opened
Jun 29, 2009
Closing Conference Date
Jul 22, 2009
Closed
Jul 22, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
204
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5401 W Luke Ave, Glendale, AZ 85301
Industry
331524 Aluminum Foundries (except Die-Casting)

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Jun 24, 2009Complaint (B) · Partial scope, Health#313587594$01 viol.

Inspection #313587594

Dates

Opened
Jun 24, 2009
Closing Conference Date
Jul 7, 2009
Closed
Jul 31, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
203
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
5401 W Luke Ave, Glendale, AZ 85301
Industry
331528

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.141
Sanitation
OSHA citation code: 19100141 A03 I
Other410$0$0Jul 20, 2009--
Mar 16, 2007Planned (H) · Complete scope, Health#310979166$01 viol.

Inspection #310979166

Dates

Opened
Mar 16, 2007
Closing Conference Date
May 1, 2007
Closed
May 22, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
194

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
5401 W. Luke, Glendale, AZ 85301
Industry
331521

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other17$0$0May 31, 2007--
Mar 13, 2007Planned (H) · Complete scope, Safety#310979133$7504 viol.

Inspection #310979133

Dates

Opened
Mar 13, 2007
Closing Conference Date
Mar 16, 2007
Closed
Jun 20, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
194

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$750
Site Address
5401 W. Luke, Glendale, AZ 85301
Industry
337122 Nonupholstered Wood Household Furniture Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious15$1,000$750Apr 29, 2007--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other65$0$0May 1, 2007--
020021910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Other15$0$0Apr 29, 2007--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other315$0$0Apr 29, 2007--
Aug 26, 2003Complaint (B) · Partial scope, Health#306344672$00 viol.

Inspection #306344672

Dates

Opened
Aug 26, 2003
Closing Conference Date
Aug 26, 2003
Closed
Aug 26, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
130
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5401 W. Luke, Glendale, AZ 85301
Industry
331521

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jun 24, 1996Referral (C) · Complete scope, Health#126984558$00 viol.

Inspection #126984558

Dates

Opened
Jun 24, 1996
Closing Conference Date
Aug 7, 1996
Closed
Aug 8, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
157
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5440 W Missouri, Glendale, AZ 85311
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Mar 25, 1992Follow-Up (F) · Partial scope, Safety#115652422$00 viol.

Inspection #115652422

Dates

Opened
Mar 25, 1992
Closing Conference Date
Mar 25, 1992
Closed
Mar 31, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
110

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5440 W Missouri, Glendale, AZ 85311
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 4, 1990FatalityAccident (A) · Partial scope, Safety#108187352$12,0002 viol.

Inspection #108187352

Dates

Opened
Dec 4, 1990
Closing Conference Date
Jan 7, 1991
Contested
Mar 4, 1991
Final Order
Aug 30, 1991
Closed
Mar 31, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
180
Related Activity
1 accident

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 willful
Initial Penalties
$12,000
Penalties on Record
$12,000
Site Address
5440 W Missouri, Glendale, AZ 85311
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityDec 4, 1990

Electric shock - contact with energized parts thru handtool

Injury: Electric ShockBody part: Body SystemSource: Electrical Apparatus/WiringEvent: Shock

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 D01 I
Willful11$8,000$8,000Feb 8, 1991Mar 4, 1991Aug 30, 1991
02001230403
OSHA citation code: 230403 A
Serious11$4,000$4,000Feb 8, 1991Mar 4, 1991Aug 30, 1991
Aug 7, 1989Follow-Up (F) · Partial scope, Safety#108195447$00 viol.

Inspection #108195447

Dates

Opened
Aug 7, 1989
Closing Conference Date
Aug 7, 1989
Closed
Aug 10, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
130

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
5440 W Missouri, Glendale, AZ 85311
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 15, 1989Planned (H) · Complete scope, Safety#108194044$1504 viol.

Inspection #108194044

Dates

Opened
Mar 15, 1989
Closing Conference Date
Mar 15, 1989
Closed
Aug 10, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
140

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$300
Penalties on Record
$150
Site Address
5440 W Missouri, Glendale, AZ 85311
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$300$150Apr 9, 1989--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other12$0$0Apr 9, 1989--
020021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other21$0$0Apr 9, 1989--
020031926.601
Motor Vehicles
OSHA citation code: 19260601 B09
Other11$0$0Apr 9, 1989--
Inspections 1 to 10 of 15, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $900
1910.95Occupational Noise Exposure4 citations · $0
1910.303Electrical - General Requirements3 citations · $150

Chemical exposure sampling

Samples
11
Substances
5
Inspections
1

Other inspected employers in GLENDALE, AZ

All employers in GLENDALE →