Skip to content
SafetyRecord logoSafetyRecord
J R D PLATING CO INC
$4,100
penalties
27
viol.
2
insp.

J R D PLATING CO INC

2600 ROBERTSON RD, TYLER, TX 75701

Inspections
2
Aug 1993 to Oct 1993 · 1 safety, 1 health
Violations
27
across 2 inspections
Penalties on record
$4,100
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 6, 1993Planned (H) · Complete scope, Health#109098822$1,10010 viol.

Inspection #109098822

Dates

Opened
Oct 6, 1993
Closing Conference Date
Oct 18, 1993
Closed
Mar 23, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
35

Violations and Penalties

Total Violations
10
Violation Types
6 serious, 4 other-than-serious
Initial Penalties
$1,875
Penalties on Record
$1,100
Site Address
2600 Robertson Rd, Tyler, TX 75701
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.94
Ventilation
OSHA citation code: 19100094 A05 IIB
Serious11$375$300Jan 5, 1994--
01001B1910.94
Ventilation
OSHA citation code: 19100094 A05 IIIB
Serious11$0$0Dec 29, 1993--
010021910.94
Ventilation
OSHA citation code: 19100094 A05 V
Serious11$375$300Jan 5, 1994--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious15$375$300Feb 10, 1994--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious15$375$200Jan 20, 1994--
010051910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious15$375$0Jan 20, 1994--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Other11$0$0Dec 28, 1993--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 B09
Other13$0$0Dec 29, 1993--
020031910.134
Respiratory Protection
OSHA citation code: 19100134 B10
Other11$0$0Jan 20, 1994--
020041910.134
Respiratory Protection
OSHA citation code: 19100134 B11
Other13$0$0Dec 29, 1993--
Aug 10, 1993Planned (H) · Complete scope, Safety#106681182$3,00017 viol.

Inspection #106681182

Dates

Opened
Aug 10, 1993
Closing Conference Date
Aug 10, 1993
Closed
Aug 3, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
24

Violations and Penalties

Total Violations
17
Violation Types
9 serious, 8 other-than-serious
Initial Penalties
$10,850
Penalties on Record
$3,000
Site Address
2600 Robertson Rd, Tyler, TX 75701
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (17 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious110$1,225$500Jan 14, 1994--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other110$1,225$0Jan 14, 1994--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious110$1,225$500Jan 14, 1994--
010041910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious11$525$250Dec 23, 1993--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,225$450Feb 7, 1994--
010061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$1,225$450Dec 22, 1993--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious12$1,225$0Dec 23, 1993--
010081910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious110$525$200Dec 23, 1993--
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious110$1,750$650Jan 14, 1994--
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious12$700$0Dec 22, 1993--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other11$0$0Dec 22, 1993--
020021904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other12$0$0Dec 30, 1993--
020031904.5
Determination of Work-Relatedness
OSHA citation code: 19040005 C
Other11$0$0Dec 23, 1993--
020041910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other16$0$0Dec 30, 1993--
020051910.134
Respiratory Protection
OSHA citation code: 19100134 F05 I
Other110$0$0Dec 23, 1993--
020061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other110$0$0Dec 22, 1993--
020071910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other13$0$0Dec 30, 1993--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection5 citations · $0
1910.94Ventilation3 citations · $600
1910.1200Hazard Communication3 citations · $500

Other inspected employers in TYLER, TX