AUGUST INTERIORS, INCORPORATED
$1,398
penalties
39
viol.
3
insp.

AUGUST INTERIORS, INCORPORATED

523 SPRING STREET, EAST BRIDGEWATER, MA 02333

Inspections
3
Jun 1986 to Aug 1994 · 3 safety, 0 health
Violations
39
across 3 inspections
Penalties on record
$1,398
latest amounts in DOL records
By classification
Serious 28Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 11, 1994Planned (H) · Complete scope, Safety#109164129$63819 viol.

Inspection #109164129

Dates

Opened
Aug 11, 1994
Closing Conference Date
Aug 11, 1994
Closed
Nov 18, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
19
Violation Types
16 serious, 3 other-than-serious
Initial Penalties
$1,275
Penalties on Record
$638
Site Address
523 Spring Street, East Bridgewater, MA 02333
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious12$375$188Oct 4, 1994--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious12$0$0Oct 4, 1994--
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious12$0$0Oct 4, 1994--
01002A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious24$300$150Oct 4, 1994--
01002B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious314$0$0Oct 4, 1994--
01002C1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious114$0$0Oct 4, 1994--
01002D1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious12$0$0Oct 4, 1994--
01002E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious12$0$0Oct 4, 1994--
01002F1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious114$0$0Oct 4, 1994--
01002G1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B02
Serious114$0$0Oct 4, 1994--
01002H1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious114$0$0Oct 4, 1994--
01002I1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious114$0$0Oct 4, 1994--
010031910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 B
Serious114$300$150Oct 4, 1994--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious114$300$150Oct 4, 1994--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious114$0$0Oct 4, 1994--
01004C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious114$0$0Oct 4, 1994--

Showing the 16 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 24, 1989Planned (H) · Complete scope, Safety#103421491$2004 viol.

Inspection #103421491

Dates

Opened
Jul 24, 1989
Closing Conference Date
Jul 24, 1989
Closed
Jan 30, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$200
Penalties on Record
$200
Site Address
523 Spring Street, East Bridgewater, MA 02333
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H03
Serious12$200$200Oct 10, 1989--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Other12$0$0Oct 10, 1989--
020021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Other12$0$0Oct 10, 1989--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other114$0$0Oct 10, 1989--
Jun 25, 1986Planned (H) · Complete scope, Safety#101145795$56016 viol.

Inspection #101145795

Dates

Opened
Jun 25, 1986
Closing Conference Date
Jun 25, 1986
Closed
Nov 14, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
16
Violation Types
11 serious, 5 other-than-serious
Initial Penalties
$560
Penalties on Record
$560
Site Address
523 Spring Street, East Bridgewater, MA 02333
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious13$160$160Nov 10, 1986--
01001B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious36$0$0Aug 25, 1986--
01001C1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Serious36$0$0Aug 25, 1986--
01001D1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Serious36$0$0Aug 25, 1986--
01001E1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 D01
Serious13$0$0Aug 25, 1986--
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious13$160$160Aug 25, 1986--
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H03
Serious13$0$0Aug 25, 1986--
01002C1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious13$0$0Aug 25, 1986--
01003A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 J03
Serious13$120$120Aug 25, 1986--
01003B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 J04
Serious13$0$0Aug 25, 1986--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 M01
Serious13$120$120Aug 25, 1986--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other118$0$0Aug 25, 1986--
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Other12$0$0Aug 25, 1986--
020031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Other13$0$0Aug 25, 1986--
020041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other12$0$0Aug 25, 1986--
020051910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other12$0$0Aug 25, 1986--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements13 citations · $600
1910.1200Hazard Communication4 citations · $150
1910.303Electrical - General Requirements4 citations · $150

Other inspected employers in EAST BRIDGEWATER, MA

All employers in EAST BRIDGEWATER →