Skip to content
SafetyRecord logoSafetyRecord
ABP SIGN COMPANY, INCORPORATED
$826
penalties
20
viol.
2
insp.

ABP SIGN COMPANY, INCORPORATED

20 WILLIAM WAY, BELLINGHAM, MA 02019

Inspections
2
Nov 1995 to Nov 1997 · 1 safety, 1 health
Violations
20
across 2 inspections
Penalties on record
$826
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 25, 1997Referral (C) · Partial scope, Health#300344918$3764 viol.

Inspection #300344918

Dates

Opened
Nov 25, 1997
Closing Conference Date
Nov 25, 1997
Closed
Feb 23, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$750
Penalties on Record
$376
Site Address
20 William Way, Bellingham, MA 02019
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Chromium, Metal and Insoluble Salts10mg/m³
Cobalt, Metal, Dust and Fume (as Co)10mg/m³
Copper Fume (as Cu)10.003mg/m³
Iron Oxide Fume10.9175mg/m³
Lead, Inorganic (as Pb)10mg/m³
Manganese Fume (as Mn)10.0325mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)10mg/m³
Vanadium fume (as V2O5)10mg/m³
Zinc Oxide Fume10.2996mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious11$375$188Jan 27, 1998--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Serious21$0$0Jan 26, 1998--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious1313$375$188Jan 27, 1998--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious1313$0$0Jan 28, 1998--
Nov 27, 1995Planned (H) · Complete scope, Safety#109169490$45016 viol.

Inspection #109169490

Dates

Opened
Nov 27, 1995
Closing Conference Date
Nov 27, 1995
Closed
Feb 12, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
16
Violation Types
7 serious, 9 other-than-serious
Initial Penalties
$450
Penalties on Record
$450
Site Address
20 William Way, Bellingham, MA 02019
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 K02
Serious13$225$225Dec 15, 1995--
01002A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious11$225$225Jan 30, 1996--
01002B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious112$0$0Dec 15, 1995--
01002C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious11$0$0Jan 30, 1996--
01002D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Serious15$0$0Dec 14, 1995--
01002E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious13$0$0Jan 30, 1996--
01002F1910.332
Electrical Safety-Related Work Practices - Training
OSHA citation code: 19100332 B01
Serious112$0$0Jan 30, 1996--
020011910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other112$0$0Jan 30, 1996--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other15$0$0Jan 30, 1996--
020031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other15$0$0Jan 30, 1996--
020041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 F02 I
Other12$0$0Jan 30, 1996--
020051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other13$0$0Dec 15, 1995--
020061910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other15$0$0Jan 30, 1996--
020071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other11$0$0Jan 30, 1996--
020081910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 IV
Other23$0$0Dec 14, 1995--
020091910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other112$0$0Jan 30, 1996--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.1200Hazard Communication3 citations · $188
1910.157Portable Fire Extinguishers2 citations · $0

Chemical exposure sampling

Samples
12
Substances
12
Inspections
1

Other inspected employers in BELLINGHAM, MA