Skip to content
SafetyRecord logoSafetyRecord
SAMSON TUG AND BARGE CO INC
$26,527
penalties
49
viol.
7
insp.

SAMSON TUG AND BARGE CO INC

8046 REZANOF DRIVE WEST, KODIAK, AK 99615

Inspections
7
May 1985 to Jun 2010 · 6 safety, 1 health
Violations
49
across 7 inspections
Penalties on record
$26,527
latest amounts in DOL records
By classification
Serious 34Willful 0Repeat 2Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 16, 2010Planned (H) · Complete scope, Safety#307506329$5,7006 viol.

Inspection #307506329

Dates

Opened
Jun 16, 2010
Closing Conference Date
Jun 16, 2010
Contested
Oct 4, 2010
Closed
Dec 29, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
8

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$8,200
Penalties on Record
$5,700
Site Address
7205 Rezanof Drive, Kodiak, AK 99615
Industry
488320 Marine Cargo Handling

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Oct 4, 2010. Final orders are recorded through Dec 29, 2011. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01002A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious14$1,200$1,200Oct 11, 2010--
01002B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 IV
Serious14$0$0Oct 11, 2010--
01002C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J04 V
Serious14$0$0Oct 11, 2010--
010031917.43
Powered Industrial Trucks
OSHA citation code: 19170043 B03
Serious24$3,000$1,500Sep 14, 2010Oct 4, 2010Dec 29, 2011
010061917.124
Dockboards (Car and Bridge Plates)
OSHA citation code: 19170124 D01
Serious14$3,000$3,000Sep 14, 2010--
020011904.40
Providing records to government representatives
OSHA citation code: 19040040 A
Other34$1,000$0Oct 11, 2010--
Jun 13, 2008Planned (H) · Complete scope, Safety#307503268$6,0001 viol.

Inspection #307503268

Dates

Opened
Jun 13, 2008
Closing Conference Date
Jun 13, 2008
Closed
Oct 6, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$6,000
Penalties on Record
$6,000
Site Address
8046 Rezanof Drive West, Kodiak, AK 99615
Industry
488320 Marine Cargo Handling

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Repeat22$6,000$6,000Jul 31, 2008--
Jun 26, 2007Planned (H) · Complete scope, Safety#307502021$4,1005 viol.

Inspection #307502021

Dates

Opened
Jun 26, 2007
Closing Conference Date
Jun 26, 2007
Closed
Dec 19, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$4,100
Penalties on Record
$4,100
Site Address
8046 Rezanof Drive West, Kodiak, AK 99615
Industry
488320 Marine Cargo Handling

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011917.112
Guarding of Edges
OSHA citation code: 19170112 A01
Serious12$1,500$1,500Nov 30, 2007--
010021918.36
Weather deck rails
Serious12$1,500$1,500Sep 17, 2007--
010031918.23
Jacob's Ladders
OSHA citation code: 19180023 A
Serious12$900$900Sep 17, 2007--
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Repeat12$200$200Sep 17, 2007--
030011917.26
First Aid and Lifesaving Facilities
OSHA citation code: 19170026 F
Other12$0$0Sep 17, 2007--
May 8, 2006Planned (H) · Complete scope, Safety#307500363$5,98720 viol.

Inspection #307500363

Dates

Opened
May 8, 2006
Closing Conference Date
May 8, 2006
Closed
Jul 20, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
11

Violations and Penalties

Total Violations
20
Violation Types
13 serious, 7 other-than-serious
Initial Penalties
$8,550
Penalties on Record
$5,987
Site Address
7205 Rezanof Drive, Kodiak, AK 99615
Industry
488320 Marine Cargo Handling

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 20 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Serious11$900$630Jun 21, 2006--
01002A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A03
Serious21$1,125$788Jun 21, 2006--
01002B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious21$0$0Jun 21, 2006--
01002C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious11$0$0Jun 21, 2006--
01002D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious21$0$0Jun 21, 2006--
01002E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious11$0$0Jun 21, 2006--
010031917.71
Terminals Handling Intermodal Containers or Roll-On Roll-Off Operations
OSHA citation code: 19170071 E
Serious22$900$630May 23, 2006--

Showing the 7 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 15, 1994Planned (H) · Complete scope, Safety#109433730$1,0503 viol.

Inspection #109433730

Dates

Opened
Jun 15, 1994
Closing Conference Date
Jun 15, 1994
Closed
Dec 20, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,750
Penalties on Record
$1,050
Site Address
8046 Rezanof Drive West, Kodiak, AK 99615
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious11$750$450Aug 19, 1994--
01002A1917.151
Machine Guarding
OSHA citation code: 19170151 B03
Serious115$1,000$600Aug 19, 1994--
01002B1917.151
Machine Guarding
OSHA citation code: 19170151 G04
Serious115$0$0Aug 17, 1994--
Jun 15, 1994Planned (H) · Complete scope, Health#109432419$3,69010 viol.

Inspection #109432419

Dates

Opened
Jun 15, 1994
Closing Conference Date
Jun 15, 1994
Closed
Feb 7, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
10
Violation Types
10 serious
Initial Penalties
$6,500
Penalties on Record
$3,690
Site Address
8046 Rezanof Drive West, Kodiak, AK 99615
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious112$1,250$750Aug 19, 1994--
01002A1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Serious13$1,250$688Sep 13, 1994--
01002B1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F02 I
Serious13$0$0Sep 13, 1994--
01002C1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 G02 I
Serious13$0$0Sep 13, 1994--
010031917.28
Hazard Communication
OSHA citation code: 19170028 E01
Serious115$750$413Sep 13, 1994--
01004A1917.28
Hazard Communication
OSHA citation code: 19170028 F05 I
Serious215$750$413Aug 29, 1994--
01004B1917.28
Hazard Communication
OSHA citation code: 19170028 F05 II
Serious215$0$0Aug 19, 1994--

Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 30, 1985Planned (H) · Complete scope, Safety#1860261$04 viol.

Inspection #1860261

Dates

Opened
May 30, 1985
Closing Conference Date
May 30, 1985
Closed
Dec 31, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Womans Bay, Kodiak, AK 99615
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other13$0$0Jun 10, 1985--
010021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other23$0$0Jun 10, 1985--
010031918.96
Maintenance and Repair Work in the Vicinity of Longshoring Operations
OSHA citation code: 19180096 E
Other13$0$0Jun 10, 1985--
010041918.105
Other Protective Measures
OSHA citation code: 19180105 A
Other13$0$0Jun 10, 1985--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment9 citations · $7,850
1917.28Hazard Communication5 citations · $1,652
1917.112Guarding of Edges3 citations · $2,130

Industry comparison

BLS 2024 survey: marine cargo handling reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 11.0%; NAICS 48832 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source