NATIONAL DIE & BUTTON MOULD CO. INC.
462 BARELL AVENUE, CARLSTADT, NJ 07072
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Nov 25, 2002#305073520Nov 25, 2002Other (L) · Records Only scope, Safety#305073520$6001 viol.1 violation$600 in penalties
Inspection #305073520
Dates
- Opened
- Nov 25, 2002
- Closing Conference Date
- Nov 25, 2002
- Closed
- Oct 23, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $600
- Penalties on Record
- $600
- Site Address
- 462 Barell Avenue, Carlstadt, NJ 07072
- Industry
- 334220 Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
Other Inspection: This inspection record is categorized as Other-L in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1904.41 Electronic Submission of Records OSHA citation code: 19040041 B02 | Other | 1 | 40 | $600 | $600 | Jan 18, 2003 | - | - |
Jun 1, 1995#114119423Jun 1, 1995Follow-Up (F) · Partial scope, Safety#114119423$00 viol.0 violations$0 in penalties
Inspection #114119423
Dates
- Opened
- Jun 1, 1995
- Closing Conference Date
- Jun 1, 1995
- Closed
- Jun 26, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 462 Barell Avenue, Carlstadt, NJ 07072
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Mar 23, 1994#109915900Mar 23, 1994Planned (H) · Complete scope, Safety#109915900$8,00020 viol.20 violations$8,000 in penalties
Inspection #109915900
Dates
- Opened
- Mar 23, 1994
- Closing Conference Date
- Mar 24, 1994
- Closed
- Mar 28, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 20
- Violation Types
- 9 serious, 11 other-than-serious
- Initial Penalties
- $22,400
- Penalties on Record
- $8,000
- Site Address
- 462 Barell Avenue, Carlstadt, NJ 07072
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 20 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.29 Fall Protection Systems and Criteria OSHA citation code: 19100029 A04 II | Other | 1 | 1 | $1,400 | $0 | Jun 14, 1994 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 4 | $1,400 | $1,000 | Nov 9, 1994 | - | - |
| 01003A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Other | 1 | 4 | $1,400 | $0 | Nov 9, 1994 | - | - |
| 01003B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C05 I | Other | 1 | 4 | $0 | $0 | Nov 9, 1994 | - | - |
| 01003C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 II | Other | 1 | 4 | $0 | $0 | Nov 9, 1994 | - | - |
| 01003D | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 IV | Serious | 1 | 4 | $0 | $0 | Nov 9, 1994 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 5 | $1,750 | $1,000 | Jun 14, 1994 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $1,750 | $1,000 | Jun 14, 1994 | - | - |
| 01006 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A04 | Serious | 1 | 1 | $1,750 | $1,000 | Sep 30, 1994 | - | - |
| 01007 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 B03 | Serious | 1 | 4 | $1,050 | $1,000 | Jun 14, 1994 | - | - |
| 01008 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 1 | 2 | $1,050 | $0 | May 30, 1994 | - | - |
| 01009 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B02 | Serious | 18 | 5 | $2,450 | $1,000 | May 30, 1995 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 23, 1994#109875526Mar 23, 1994Planned (H) · Complete scope, Health#109875526$4,00010 viol.10 violations$4,000 in penalties
Inspection #109875526
Dates
- Opened
- Mar 23, 1994
- Closing Conference Date
- Mar 24, 1994
- Closed
- Aug 4, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 4 serious, 6 other-than-serious
- Initial Penalties
- $7,700
- Penalties on Record
- $4,000
- Site Address
- 462 Barell Avenue, Carlstadt, NJ 07072
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 4 | $1,050 | $1,000 | Aug 30, 1994 | - | - |
| 01002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Serious | 1 | 20 | $1,050 | $1,000 | Oct 14, 1994 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Other | 1 | 4 | $1,750 | $0 | Aug 30, 1994 | - | - |
| 01004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B01 | Serious | 1 | 6 | $1,750 | $1,000 | May 30, 1995 | - | - |
| 01005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 8 | $1,050 | $1,000 | Jun 13, 1994 | - | - |
| 01006A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 12 | $1,050 | $0 | Oct 30, 1994 | - | - |
| 01006B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Other | 3 | 12 | $0 | $0 | Nov 11, 1994 | - | - |
| 01006C | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Other | 2 | 12 | $0 | $0 | Nov 11, 1994 | - | - |
| 01006D | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Other | 1 | 10 | $0 | $0 | Jun 13, 1994 | - | - |
| 02001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 D09 I | Other | 1 | 4 | $0 | $0 | Oct 30, 1994 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1994 to 2002. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.