PARKSON CORP
201 SW 12 AVENUE, Pompano Beach, FL 33060
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jul 3, 1990#110055688Jul 3, 1990FatalityAccident (A) · Partial scope, SafetyFatality#110055688$1,3002 viol.2 violations$1,300 in penalties
Inspection #110055688
Dates
- Opened
- Jul 3, 1990
- Closing Conference Date
- Jul 6, 1990
- Closed
- Nov 8, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 60
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $1,300
- Penalties on Record
- $1,300
- Site Address
- 231 Sw 12th Ave., Pompano Beach, FL 33069
- Industry
- Not classified in OSHA's inspection record.
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Electric shock - ground fault in receptacle
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 4 | $800 | $800 | Oct 4, 1990 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 E01 | Serious | 1 | 4 | $500 | $500 | Oct 5, 1990 | - | - |
Oct 4, 1989#18397430Oct 4, 1989Planned (H) · Complete scope, Safety#18397430$6408 viol.8 violations$640 in penalties
Inspection #18397430
Dates
- Opened
- Oct 4, 1989
- Closing Conference Date
- Oct 4, 1989
- Closed
- Dec 22, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 70
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 5 serious, 3 other-than-serious
- Initial Penalties
- $980
- Penalties on Record
- $640
- Site Address
- 231 Sw 12th Ave., Pompano Beach, FL 33069
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $210 | $150 | Dec 22, 1989 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $280 | $180 | Dec 22, 1989 | - | - |
| 01003 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 2 | $140 | $80 | Oct 24, 1989 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 1 | $140 | $80 | Oct 22, 1989 | - | - |
| 01005 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 1 | 1 | $210 | $150 | Oct 22, 1989 | - | - |
| 02001 | 1910.184 Slings OSHA citation code: 19100184 E01 | Other | 1 | 1 | $0 | $0 | Nov 21, 1989 | - | - |
| 02002 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 1 | 2 | $0 | $0 | Oct 22, 1989 | - | - |
| 02003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 II | Other | 1 | 2 | $0 | $0 | Oct 28, 1989 | - | - |
May 19, 1986#100370600May 19, 1986Monitoring (D) · Partial scope, Safety#100370600$00 viol.0 violations$0 in penalties
Inspection #100370600
Dates
- Opened
- May 19, 1986
- Closing Conference Date
- May 19, 1986
- Closed
- May 19, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 201 Sw 12th Ave., Pompano Beach, FL 33060
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Jan 23, 1986#101715019Jan 23, 1986FatalityAccident (A) · Complete scope, SafetyFatality#101715019$74510 viol.10 violations$745 in penalties
Inspection #101715019
Dates
- Opened
- Jan 23, 1986
- Closing Conference Date
- Mar 25, 1986
- Closed
- Sep 16, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 8 serious, 2 other-than-serious
- Initial Penalties
- $1,440
- Penalties on Record
- $745
- Site Address
- 201 Sw 12th Ave., Pompano Beach, FL 33060
- Industry
- Not classified in OSHA's inspection record.
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Burned when spilled gasoline ignited by engine backfire
Violations
Violation list (8 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 I | Serious | 2 | 3 | $450 | $225 | Apr 5, 1986 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 1 | 1 | $450 | $250 | Jul 1, 1986 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 1 | 1 | $0 | $0 | Oct 1, 1986 | - | - |
| 01002C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Serious | 1 | 1 | $0 | $0 | Apr 5, 1986 | - | - |
| 01002D | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 E02 | Serious | 1 | 1 | $0 | $0 | Apr 5, 1986 | - | - |
| 01002E | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | 1 | $0 | $0 | Apr 5, 1986 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $270 | $135 | Apr 5, 1986 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $270 | $135 | Apr 5, 1986 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 26, 1982#13330410May 26, 1982Planned (H) · Complete scope, Safety#13330410$2608 viol.8 violations$260 in penalties
Inspection #13330410
Dates
- Opened
- May 26, 1982
- Closing Conference Date
- Jun 21, 1982
- Closed
- Aug 2, 1982
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 171
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 2 serious, 6 other-than-serious
- Initial Penalties
- $660
- Penalties on Record
- $260
- Site Address
- 201 Sw 12 Avenue, Pompano Beach, FL 33060
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 3 | - | $300 | $100 | Nov 20, 1982 | - | - |
| 01002 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E02 III | Serious | 6 | - | $360 | $160 | Aug 16, 1982 | - | - |
| 02001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Other | 1 | - | $0 | $0 | Jul 9, 1982 | - | - |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E09 III | Other | 1 | - | $0 | $0 | Aug 16, 1982 | - | - |
| 02003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 2 | - | $0 | $0 | Jul 9, 1982 | - | - |
| 02004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Other | 1 | - | $0 | $0 | Jul 9, 1982 | - | - |
| 02005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 2 | - | $0 | $0 | Aug 16, 1982 | - | - |
| 02006 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 2 | - | $0 | $0 | Jul 9, 1982 | - | - |
May 19, 1982#13429279May 19, 1982Planned (H) · Complete scope, Health#13429279$04 viol.4 violations$0 in penalties
Inspection #13429279
Dates
- Opened
- May 19, 1982
- Closing Conference Date
- Jun 17, 1982
- Closed
- Nov 10, 1982
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 171
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 201 Sw 12 Avenue, Pompano Beach, FL 33060
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 C07 IIIB | Other | 1 | - | $0 | $0 | Aug 20, 1982 | - | - |
| 01002A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B01 | Other | 1 | - | $0 | $0 | Mar 29, 1983 | - | - |
| 01002B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 E01 | Other | 26 | - | $0 | $0 | Aug 20, 1982 | - | - |
| 01003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 D02 II | Other | 3 | - | $0 | $0 | Sep 9, 1982 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1982 to 1990. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.