Skip to content
SafetyRecord logoSafetyRecord
DIDION MID SOUTH CORP.
$7,400
penalties
62
viol.
4
insp.

DIDION MID SOUTH CORP.

4721 S. ZERO, FORT SMITH, AR 72903

Inspections
4
Jan 1993 to Jul 1994 · 2 safety, 2 health
Violations
62
across 4 inspections
Penalties on record
$7,400
latest amounts in DOL records
By classification
Serious 32Willful 0Repeat 5Other 25

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 13, 1994Referral (C) · Partial scope, Health#107700106$2,00019 viol.

Inspection #107700106

Dates

Opened
Jul 13, 1994
Closing Conference Date
Oct 6, 1994
Closed
Oct 13, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
138
Related Activity
1 referral

Violations and Penalties

Total Violations
19
Violation Types
4 serious, 4 repeat, 11 other-than-serious
Initial Penalties
$15,660
Penalties on Record
$2,000
Site Address
4721 S. Zero, Fort Smith, AR 72903
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium10mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0001mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40mg/m³
Dimethylethylamine92.5399 - 15.1058ppm
Formaldehyde90 - 1.0639ppm
Iron Oxide Fume40 - 1.0956mg/m³
Lead, Inorganic (as Pb)40 - 0.0112mg/m³
Magnesium Oxide Fume (Total Particulate)30.1144 - 0.1583mg/m³
Manganese Fume (as Mn)40 - 0.0121mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Toluene-2,6-Diisocyanate100.0045 - 0.0113mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40 - 0.3196mg/m³

Violations

Violation list (12 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 B
Serious11$2,275$1,000Dec 18, 1994--
01003A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 III
Other11$975$0Jan 17, 1995--
01003B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Other11$0$0Jan 30, 1995--
010041910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Other21$1,300$0Dec 18, 1994--
01006A1910.134
Respiratory Protection
OSHA citation code: 19100134 B09
Other11$1,300$0Dec 12, 1994--
01006B1910.134
Respiratory Protection
OSHA citation code: 19100134 B11
Other11$0$0Dec 12, 1994--
01008A1910.1025
Lead
OSHA citation code: 19101025 L01 I
Serious12$1,625$360Dec 18, 1994--
01008B1910.1025
Lead
OSHA citation code: 19101025 L01 II
Serious12$0$0Dec 18, 1994--
01008C1910.1025
Lead
OSHA citation code: 19101025 L02 I
Serious11$0$0Dec 18, 1994--
010101910.1048
Formaldehyde
OSHA citation code: 19101048 N02 I
Other11$1,625$0Dec 18, 1994--
020011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Repeat11$160$160Dec 12, 1994--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Repeat11$1,600$160Dec 12, 1994--

Showing the 12 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 11, 1994Complaint (B) · Partial scope, Safety#110357027$2,00019 viol.

Inspection #110357027

Dates

Opened
Jul 11, 1994
Closing Conference Date
Jul 15, 1994
Closed
Jan 25, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
138
Related Activity
1 complaint

Violations and Penalties

Total Violations
19
Violation Types
12 serious, 1 repeat, 6 other-than-serious
Initial Penalties
$22,400
Penalties on Record
$2,000
Site Address
4721 S. Zero, Fort Smith, AR 72903
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (12 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious25$2,000$200Aug 10, 1994--
010021910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 D
Serious12$1,200$145Aug 30, 1994--
010031910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 E02
Other12$1,200$0Aug 30, 1994--
010041910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 F01
Serious12$1,200$145Aug 30, 1994--
010051910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 G06 IV
Other12$1,200$0Aug 30, 1994--
01006A1910.141
Sanitation
OSHA citation code: 19100141 C02 I
Other115$1,200$0Aug 30, 1994--
01006B1910.141
Sanitation
OSHA citation code: 19100141 D02 I
Other115$0$0Aug 30, 1994--
01008A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious98$2,800$145Aug 30, 1994--
01008B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious87$0$0Aug 30, 1994--
01009A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$1,200$145Aug 30, 1994--
01009B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$0$0Aug 30, 1994--
010101910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious13$2,000$200Aug 30, 1994--

Showing the 12 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 26, 1993Planned (H) · Complete scope, Health#107606246$1,40010 viol.

Inspection #107606246

Dates

Opened
May 26, 1993
Closing Conference Date
May 27, 1993
Closed
Apr 26, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
145

Violations and Penalties

Total Violations
10
Violation Types
5 serious, 5 other-than-serious
Initial Penalties
$4,400
Penalties on Record
$1,400
Site Address
4721 S. Zero, Fort Smith, AR 72903
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious11$1,375$440Jul 19, 1993--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$825$260Aug 2, 1993--
010031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious11$1,375$440Jul 19, 1993--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious11$825$260Aug 2, 1993--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious11$0$0Aug 2, 1993--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other11$0$0Aug 2, 1993--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Other11$0$0Aug 2, 1993--
020031910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Other11$0$0Aug 2, 1993--
020041910.134
Respiratory Protection
OSHA citation code: 19100134 B05
Other11$0$0Aug 2, 1993--
020051910.134
Respiratory Protection
OSHA citation code: 19100134 B06
Other11$0$0Aug 2, 1993--
Jan 14, 1993Planned (H) · Complete scope, Safety#107703324$2,00014 viol.

Inspection #107703324

Dates

Opened
Jan 14, 1993
Closing Conference Date
Jan 15, 1993
Contested
Mar 29, 1993
Final Order
Dec 10, 1993
Closed
Apr 28, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
145

Violations and Penalties

Total Violations
14
Violation Types
11 serious, 3 other-than-serious
Initial Penalties
$20,650
Penalties on Record
$2,000
Site Address
4721 S. Zero, Fort Smith, AR 72903
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Serious11$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993
010021910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 E02
Serious11$3,500$345Mar 29, 1993Mar 29, 1993Dec 10, 1993
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious22$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993
010041910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 G01 V
Serious22$1,400$135Mar 8, 1993Mar 29, 1993Dec 10, 1993
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993
010061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious22$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993
010071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious44$1,400$135Mar 8, 1993Mar 29, 1993Dec 10, 1993
010081910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 IVD
Serious22$1,400$135Mar 8, 1993Mar 29, 1993Dec 10, 1993
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious33$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious11$1,400$135Mar 9, 1993Mar 29, 1993Dec 10, 1993
010111910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious11$2,450$240Mar 9, 1993Mar 29, 1993Dec 10, 1993
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other11$1,400$135Mar 29, 1993Mar 29, 1993Dec 10, 1993

Showing the 12 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection9 citations · $320
1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $1,155
1910.1200Hazard Communication5 citations · $660

Chemical exposure sampling

Samples
79
Substances
17
Inspections
1

Other inspected employers in FORT SMITH, AR