ANODICS, INC.
4105 MURRAY AVE., FORT WORTH, TX 76117
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 2, 2025#348158031Apr 2, 2025Referral (C) · Partial scope, Health#348158031$3,4062 viol.2 violations$3,406 in penalties
Inspection #348158031
Dates
- Opened
- Apr 2, 2025
- Closing Conference Date
- Apr 3, 2025
- Final Order
- Nov 17, 2025
- Closed
- Nov 17, 2025
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 14
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $5,676
- Penalties on Record
- $3,406
- Site Address
- 4105 Murray Avenue, Fort Worth, TX 76117
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1026 Chromium (VI) OSHA citation code: 19101026 H01 | Serious | 1 | 9 | $2,838 | $1,703 | Oct 31, 2025 | - | Nov 17, 2025 |
| 01002 | 1910.1026 Chromium (VI) OSHA citation code: 19101026 I04 I | Serious | 1 | 9 | $2,838 | $1,703 | Oct 31, 2025 | - | Nov 17, 2025 |
Mar 17, 2025#348113382Mar 17, 2025Planned (H) · Complete scope, Safety#348113382$3,4043 viol.3 violations$3,404 in penalties
Inspection #348113382
Dates
- Opened
- Mar 17, 2025
- Closing Conference Date
- Mar 17, 2025
- Final Order
- Jun 20, 2025
- Closed
- Jun 26, 2025
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 13
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $5,674
- Penalties on Record
- $3,404
- Site Address
- 4105 Murray Avenue, Fort Worth, TX 76117
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 4 | $2,837 | $1,702 | Jun 30, 2025 | - | Jun 20, 2025 |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 4 | $2,837 | $1,702 | Jun 30, 2025 | - | Jun 20, 2025 |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 4 | $0 | $0 | Jun 30, 2025 | - | Jun 20, 2025 |
Jun 25, 1992#110366143Jun 25, 1992Planned (H) · Complete scope, Health#110366143$802 viol.2 violations$80 in penalties
Inspection #110366143
Dates
- Opened
- Jun 25, 1992
- Closing Conference Date
- Jul 1, 1992
- Closed
- Sep 18, 1992
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 11
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 repeat, 1 other-than-serious
- Initial Penalties
- $80
- Penalties on Record
- $80
- Site Address
- 4105 Murray Ave., Fort Worth, TX 76117
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 V | Repeat | 1 | 2 | $80 | $80 | Aug 18, 1992 | - | - |
| 02001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 8 | $0 | $0 | Aug 18, 1992 | - | - |
Jun 11, 1990#106603368Jun 11, 1990Referral (C) · Partial scope, Health#106603368$2826 viol.6 violations$282 in penalties
Inspection #106603368
Dates
- Opened
- Jun 11, 1990
- Closing Conference Date
- Jun 11, 1990
- Closed
- Jul 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 2 serious, 4 other-than-serious
- Initial Penalties
- $400
- Penalties on Record
- $282
- Site Address
- 4105 Murray Ave., Fort Worth, TX 76117
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 5 | $150 | $112 | Jul 9, 1990 | - | - |
| 01003 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 5 | $250 | $170 | Jul 9, 1990 | - | - |
| 02001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 XI | Other | 1 | 15 | $0 | $0 | Aug 1, 1990 | - | - |
| 02002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B01 | Other | 1 | 2 | $0 | $0 | Jul 18, 1990 | - | - |
| 02003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B02 | Other | 1 | 2 | $0 | $0 | Jul 18, 1990 | - | - |
| 02004 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B09 | Other | 1 | 2 | $0 | $0 | Jul 18, 1990 | - | - |
Jun 4, 1990#106597834Jun 4, 1990Planned (H) · Complete scope, Safety#106597834$45713 viol.13 violations$457 in penalties
Inspection #106597834
Dates
- Opened
- Jun 4, 1990
- Closing Conference Date
- Jun 5, 1990
- Closed
- Sep 13, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 15
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 7 serious, 6 other-than-serious
- Initial Penalties
- $720
- Penalties on Record
- $457
- Site Address
- 4105 Murray Ave., Fort Worth, TX 76117
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 2 | 7 | $60 | $50 | Jul 13, 1990 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 10 | $90 | $67 | Jul 18, 1990 | - | - |
| 01003A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 5 | $90 | $67 | Jul 18, 1990 | - | - |
| 01003B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Serious | 1 | 5 | $0 | $0 | Jul 18, 1990 | - | - |
| 01004 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 3 | 6 | $210 | $147 | Jul 9, 1990 | - | - |
| 01005A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 5 | $180 | $126 | Jul 9, 1990 | - | - |
| 01005B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 5 | $0 | $0 | Jul 9, 1990 | - | - |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Other | 1 | 15 | $90 | $0 | Jul 9, 1990 | - | - |
| 02002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q01 | Other | 3 | 15 | $0 | $0 | Jul 13, 1990 | - | - |
| 02003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Other | 1 | 5 | $0 | $0 | Jul 13, 1990 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1990 to 2025. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source