Feb 21, 1991#110398591Feb 21, 1991Complaint (B) · Partial scope, Health#110398591$09 viol.9 violations$0 in penalties
Inspection #110398591
Dates
- Opened
- Feb 21, 1991
- Closing Conference Date
- Mar 28, 1991
- Closed
- Sep 23, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 2 serious, 7 repeat
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling9 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Hexamethylene Diisocyanate | 2 | 0 | mg/m³ |
| Hexamethylene Diisocyanate Biuret | 2 | 0 | mg/m³ |
| Hexone | 8 | 0 | ppm |
| Isobutyl Alcohol | 8 | 0 - 0.0513 | ppm |
| n-Butyl Acetate | 8 | 0 - 0.0881 | ppm |
| n-Butyl Alcohol | 8 | 0 - 0.0385 | ppm |
| sec-Hexyl Acetate | 8 | 0 - 0.0556 | ppm |
| Toluene | 8 | 0 - 3.0511 | ppm |
| Xylene | 8 | 0 | ppm |
Violations
Violation list (5 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E05 V | Serious | 2 | 26 | $0 | $0 | Jun 3, 1991 | - | - |
| 01002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | 26 | $0 | $0 | Jun 3, 1991 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Repeat | 3 | 26 | $0 | $0 | Jun 3, 1991 | - | - |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Repeat | 1 | 28 | $0 | $0 | May 2, 1991 | - | - |
| 02003 | 1910.145 Specifications for Accident Prevention Signs and Tags OSHA citation code: 19100145 C03 | Repeat | 2 | 26 | $0 | $0 | May 2, 1991 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 23, 1991#100659960Jan 23, 1991Complaint (B) · Partial scope, Health#100659960$01 viol.1 violation$0 in penalties
Inspection #100659960
Dates
- Opened
- Jan 23, 1991
- Closing Conference Date
- Jan 23, 1991
- Closed
- Sep 26, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Other | 1 | 100 | $0 | $0 | Jun 17, 1991 | - | - |
Sep 20, 1990#110396082Sep 20, 1990Complaint (B) · Partial scope, Health#110396082$00 viol.0 violations$0 in penalties
Inspection #110396082
Dates
- Opened
- Sep 20, 1990
- Closing Conference Date
- Oct 2, 1990
- Closed
- Feb 6, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,000
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Apr 9, 1990#110392396Apr 9, 1990Complaint (B) · Partial scope, Safety#110392396$04 viol.4 violations$0 in penalties
Inspection #110392396
Dates
- Opened
- Apr 9, 1990
- Closing Conference Date
- Apr 11, 1990
- Closed
- Aug 27, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 10201 OSHA citation code: 10201 A | Serious | 1 | 3 | $0 | $0 | Aug 21, 1990 | - | - |
| 01002 | 10201 OSHA citation code: 10201 A | Serious | 1 | 3 | $0 | $0 | Aug 21, 1990 | - | - |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Serious | 1 | 1 | $0 | $0 | Aug 7, 1990 | - | - |
| 01004 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $0 | $0 | Aug 7, 1990 | - | - |
Feb 28, 1990#110391638Feb 28, 1990Complaint (B) · Partial scope, Safety#110391638$03 viol.3 violations$0 in penalties
Inspection #110391638
Dates
- Opened
- Feb 28, 1990
- Closing Conference Date
- Feb 28, 1990
- Closed
- May 4, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
- Related Activity
- 2 complaints
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 repeat
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Repeat | 1 | 5 | $0 | $0 | Apr 17, 1990 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Repeat | 1 | 5 | $0 | $0 | Apr 23, 1990 | - | - |
| 01003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Repeat | 1 | 5 | $0 | $0 | Apr 23, 1990 | - | - |
Feb 22, 1990#110391422Feb 22, 1990Follow-Up (F) · Partial scope, Health#110391422$02 viol.2 violations$0 in penalties
Inspection #110391422
Dates
- Opened
- Feb 22, 1990
- Closing Conference Date
- Feb 22, 1990
- Closed
- Oct 26, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Asbestos (all forms) | 2 | 0 | f/cc |
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 2 | 12 | $0 | $0 | Jun 2, 1990 | - | - |
| 01002 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A02 | Serious | 1 | 10 | $0 | $0 | Jun 2, 1990 | - | - |
Nov 21, 1989#110389376Nov 21, 1989Unprogrammed Related (G) · Partial scope, Health#110389376$04 viol.4 violations$0 in penalties
Inspection #110389376
Dates
- Opened
- Nov 21, 1989
- Closing Conference Date
- Dec 13, 1989
- Closed
- Feb 1, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 serious, 1 repeat, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.120 Hazardous Waste Operations and Emergency Response OSHA citation code: 19100120 L03 I | Serious | 1 | 1 | $0 | $0 | Feb 21, 1990 | - | - |
| 02001 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Repeat | 1 | 6 | $0 | $0 | Feb 13, 1990 | - | - |
| 03001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A02 I | Other | 1 | 2 | $0 | $0 | Jan 29, 1990 | - | - |
| 03002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 E03 | Other | 1 | 1 | $0 | $0 | Jan 29, 1990 | - | - |
Oct 13, 1989#102331980Oct 13, 1989Complaint (B) · Partial scope, Safety#102331980$01 viol.1 violation$0 in penalties
Inspection #102331980
Dates
- Opened
- Oct 13, 1989
- Closing Conference Date
- Oct 13, 1989
- Closed
- Dec 8, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.176 Handling Materials - General OSHA citation code: 19100176 A | Other | 1 | 7 | $0 | $0 | Nov 1, 1989 | - | - |
Apr 4, 1989#100654276Apr 4, 1989Planned (H) · Complete scope, Health#100654276$0130 viol.130 violations$0 in penalties
Inspection #100654276
Dates
- Opened
- Apr 4, 1989
- Closing Conference Date
- Jun 19, 1989
- Closed
- Jan 30, 1992
Inspection
- Advance Notice
- Yes
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
Violations and Penalties
- Total Violations
- 130
- Violation Types
- 108 serious, 8 repeat, 14 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling22 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 11 | 0 | mg/m³ |
| Arsenic, Inorganic | 2 | 0 | mg/m³ |
| Asbestos (all forms) | 71P / 6A | 0 - 0.009 | f/cc |
| Beryllium and Beryllium Compounds (as Be) | 11 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 11 | 0 - 0.0196 | mg/m³ |
| Chromic Acid and Chromates (as CrO3) | 6 | 0 - 0.69 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 11 | 0 - 3.904 | mg/m³ |
| Chromium, Soluble Chromic, Chromous Salts (as Cr) | 9 | 0 - 1.1 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 11 | 0 | mg/m³ |
| Copper Fume (as Cu) | 11 | 0 | mg/m³ |
| Fibrous Glass Dust | 1 | 0.09 | f/cc |
| Iron Oxide Fume | 11 | 0 - 12.7463 | mg/m³ |
| Lead, Inorganic (as Pb) | 20 | 0 - 0.5158 | mg/m³ |
| Manganese Fume (as Mn) | 11 | 0 - 0.047 | mg/m³ |
| Methylene bisphenyl isocyanate | 3 | 0 | |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 7 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 11 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 15 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 4 | 0 | mg/m³ |
| Toluene-2,6-Diisocyanate | 4 | 0 - 0.01 | |
| Vanadium fume (as V2O5) | 11 | 0 | mg/m³ |
| Zinc Oxide Fume | 11 | 0 - 1.1598 | mg/m³ |
Violations
Violation list (5 of 130 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01003 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Serious | 4 | 50 | $0 | $0 | Jan 20, 1990 | - | - |
| 01004 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Serious | 3 | 50 | $0 | $0 | Feb 15, 1990 | - | - |
| 01005 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Serious | 1 | 3 | $0 | $0 | Sep 20, 1989 | - | - |
| 01006 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D02 | Serious | 3 | 50 | $0 | $0 | Feb 15, 1990 | - | - |
| 01007 | 1910.23 Ladders OSHA citation code: 19100023 A02 | Serious | 1 | 5 | $0 | $0 | Nov 29, 1989 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 130 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Failure to Abate Penalties3 citations
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|
Showing the 0 FTA rows present in the first 5 citations on this inspection. OSHA's record shows 3 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.
Apr 4, 1989#2441582Apr 4, 1989Planned (H) · Complete scope, Safety#2441582$056 viol.56 violations$0 in penalties
Inspection #2441582
Dates
- Opened
- Apr 4, 1989
- Closing Conference Date
- Jun 19, 1989
- Closed
- Oct 16, 1991
Inspection
- Advance Notice
- Yes
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 4,200
Violations and Penalties
- Total Violations
- 56
- Violation Types
- 52 serious, 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 109 Crecy St, Corpus Christi, TX 78419
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 56 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Serious | 3 | 60 | $0 | $0 | Aug 20, 1989 | - | - |
| 01002 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 13 | 200 | $0 | $0 | Nov 18, 1989 | - | - |
| 01003 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Serious | 2 | 40 | $0 | $0 | Sep 20, 1989 | - | - |
| 01004 | 1910.23 Ladders OSHA citation code: 19100023 E03 IV | Serious | 3 | 50 | $0 | $0 | Nov 18, 1989 | - | - |
| 01005 | 1910.24 Step Bolts and Manhole Steps OSHA citation code: 19100024 E | Serious | 2 | 40 | $0 | $0 | Jun 1, 1990 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 56 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
32 inspections, 1987 to 2007. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
BLS 2024 survey: aircraft engine and engine parts manufacturing reported 1.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.8%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source