TRI ANGLE METAL FAB
100 GONYEAU RD., MILTON, VT 05468
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 7, 2008#311477558Aug 7, 2008Planned (H) · Complete scope, Health#311477558$02 viol.2 violations$0 in penalties
Inspection #311477558
Dates
- Opened
- Aug 7, 2008
- Closing Conference Date
- Aug 7, 2008
- Closed
- Oct 13, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 61
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 100 Gonyeau Rd., Milton, VT 05468
- Industry
- 332710 Machine Shops
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.145 Specifications for Accident Prevention Signs and Tags OSHA citation code: 19100145 C03 | Other | 1 | 2 | $0 | $0 | Oct 15, 2008 | - | - |
| 01002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 6 | $0 | $0 | Oct 15, 2008 | - | - |
Aug 13, 1996#301484622Aug 13, 1996Planned (H) · Complete scope, Safety#301484622$1,5008 viol.8 violations$1,500 in penalties
Inspection #301484622
Dates
- Opened
- Aug 13, 1996
- Closing Conference Date
- Aug 13, 1996
- Closed
- Sep 13, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 58
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 8 serious
- Initial Penalties
- $1,500
- Penalties on Record
- $1,500
- Site Address
- 100 Gonyeau Rd., Milton, VT 05468
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $375 | $375 | Sep 11, 1996 | - | - |
| 01001B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $0 | $0 | Sep 10, 1996 | - | - |
| 01001C | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 1 | $0 | $0 | Sep 10, 1996 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 I02 | Serious | 1 | 1 | $375 | $375 | Sep 10, 1996 | - | - |
| 01003A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 II | Serious | 1 | 1 | $375 | $375 | Sep 10, 1996 | - | - |
| 01003B | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Serious | 1 | 1 | $0 | $0 | Sep 10, 1996 | - | - |
| 01003C | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Serious | 1 | 1 | $0 | $0 | Sep 10, 1996 | - | - |
| 01004 | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 I | Serious | 1 | 1 | $375 | $375 | Sep 10, 1996 | - | - |
Sep 2, 1992#111709705Sep 2, 1992Planned (H) · Complete scope, Safety#111709705$1,30018 viol.18 violations$1,300 in penalties
Inspection #111709705
Dates
- Opened
- Sep 2, 1992
- Closing Conference Date
- Sep 3, 1992
- Closed
- May 15, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 56
Violations and Penalties
- Total Violations
- 18
- Violation Types
- 12 serious, 6 other-than-serious
- Initial Penalties
- $1,300
- Penalties on Record
- $1,300
- Site Address
- 100 Gonyeau Rd., Milton, VT 05468
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (16 of 18 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 4 | $150 | $150 | Feb 20, 1993 | - | - |
| 01002A | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 F02 | Serious | 1 | 1 | $150 | $150 | Feb 20, 1993 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 1 | 1 | $0 | $0 | Feb 20, 1993 | - | - |
| 01002C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 1 | 1 | $0 | $0 | Feb 20, 1993 | - | - |
| 01002D | 1910.307 Electrical - Hazardous (Classified) Locations OSHA citation code: 19100307 B | Serious | 1 | 1 | $0 | $0 | Feb 20, 1993 | - | - |
| 01003 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 5 | $200 | $200 | Feb 20, 1993 | - | - |
| 01004A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 8 | $350 | $350 | Feb 20, 1993 | - | - |
| 01004B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 4 | 5 | $0 | $0 | Feb 20, 1993 | - | - |
| 01005 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Serious | 4 | 6 | $200 | $200 | Feb 20, 1993 | - | - |
| 01006A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 3 | $250 | $250 | Feb 20, 1993 | - | - |
| 01006B | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 1 | $0 | $0 | Feb 20, 1993 | - | - |
| 01006C | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 2 | 4 | $0 | $0 | Feb 20, 1993 | - | - |
| 02001A | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E02 | Other | 6 | 56 | $0 | $0 | Feb 20, 1993 | - | - |
| 02001B | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Other | 1 | 56 | $0 | $0 | Mar 8, 1993 | - | - |
| 02002A | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 E04 | Other | 1 | 50 | $0 | $0 | Feb 20, 1993 | - | - |
| 02002B | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J03 | Other | 1 | 50 | $0 | $0 | Feb 20, 1993 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1992 to 2008. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: machine shops reported 2.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.0%; NAICS 33271 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source