NEW YORK WIRE COMPANY
829 LOUCKS MILL ROAD, YORK, PA 17405 · NAICS 332618 Other Fabricated Wire Product Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Feb 7, 2011#314242819Feb 7, 2011Planned (H) · Complete scope, Safety#314242819$2,6804 viol.4 violations$2,680 in penalties
Inspection #314242819
Dates
- Opened
- Feb 7, 2011
- Closing Conference Date
- Apr 7, 2011
- Closed
- May 17, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 160
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $3,575
- Penalties on Record
- $2,680
- Site Address
- 441 East Market Street, York, PA 17403
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 2 | $975 | $730 | May 2, 2011 | - | - |
| 01001B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 2 | $0 | $0 | May 2, 2011 | - | - |
| 01002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 II | Serious | 1 | 1 | $1,300 | $975 | May 2, 2011 | - | - |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 F | Serious | 1 | 1 | $1,300 | $975 | May 2, 2011 | - | - |
Mar 15, 2007#112904545Mar 15, 2007Planned (H) · Complete scope, Safety#112904545$2,6755 viol.5 violations$2,675 in penalties
Inspection #112904545
Dates
- Opened
- Mar 15, 2007
- Closing Conference Date
- Mar 26, 2007
- Closed
- Jun 7, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $3,825
- Penalties on Record
- $2,675
- Site Address
- 441 East Market Street, York, PA 17403
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 D01 III | Serious | 1 | 1 | $1,275 | $895 | May 4, 2007 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 1 | 1 | $1,275 | $890 | Apr 13, 2007 | - | - |
| 01003A | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 I | Serious | 1 | 1 | $1,275 | $890 | Apr 13, 2007 | - | - |
| 01003B | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 II | Serious | 1 | 1 | $0 | $0 | Apr 13, 2007 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 D01 | Other | 2 | 2 | $0 | $0 | May 31, 2007 | - | - |
Dec 21, 2004#305843476Dec 21, 2004Planned (H) · Complete scope, Safety#305843476$1,4004 viol.4 violations$1,400 in penalties
Inspection #305843476
Dates
- Opened
- Dec 21, 2004
- Closing Conference Date
- Dec 22, 2004
- Closed
- Feb 16, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 2 other-than-serious
- Initial Penalties
- $2,550
- Penalties on Record
- $1,400
- Site Address
- 441 East Market Street, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 D02 | Serious | 1 | 1 | $1,275 | $700 | Feb 9, 2005 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | 2 | $1,275 | $700 | Feb 9, 2005 | - | - |
| 02001 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Other | 1 | 1 | $0 | $0 | Feb 15, 2005 | - | - |
| 02002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 19 | 1 | $0 | $0 | Feb 15, 2005 | - | - |
Sep 18, 2002#112991823Sep 18, 2002Planned (H) · Complete scope, Safety#112991823$2,7507 viol.7 violations$2,750 in penalties
Inspection #112991823
Dates
- Opened
- Sep 18, 2002
- Closing Conference Date
- Sep 18, 2002
- Contested
- Oct 22, 2002
- Final Order
- Feb 12, 2003
- Closed
- Feb 14, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 140
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 3 serious, 4 other-than-serious
- Initial Penalties
- $7,500
- Penalties on Record
- $2,750
- Site Address
- 441 East Market Street, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 1 | $1,500 | $750 | Oct 3, 2002 | Oct 22, 2002 | Feb 12, 2003 |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B02 | Serious | 1 | 1 | $2,000 | $1,000 | Oct 25, 2002 | Oct 22, 2002 | Feb 12, 2003 |
| 01003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F01 | Other | 1 | 1 | $2,000 | $0 | Oct 25, 2002 | Oct 22, 2002 | Feb 12, 2003 |
| 01004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 I02 | Serious | 1 | 1 | $2,000 | $1,000 | Oct 25, 2002 | Oct 22, 2002 | Feb 12, 2003 |
| 02001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 G02 | Other | 1 | 1 | $0 | $0 | Oct 25, 2002 | Oct 22, 2002 | Feb 12, 2003 |
Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 19, 2002#112988340Aug 19, 2002Planned (H) · Complete scope, Health#112988340$2,19511 viol.11 violations$2,195 in penalties
Inspection #112988340
Dates
- Opened
- Aug 19, 2002
- Closing Conference Date
- Aug 20, 2002
- Closed
- Nov 13, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 80
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 7 serious, 4 other-than-serious
- Initial Penalties
- $3,375
- Penalties on Record
- $2,195
- Site Address
- 829 Loucks Mill Road, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 1 | 8 | $1,125 | $735 | Sep 30, 2002 | - | - |
| 01001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 8 | $0 | $0 | Oct 30, 2002 | - | - |
| 01001C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 IV | Serious | 1 | 8 | $0 | $0 | Oct 30, 2002 | - | - |
| 01001D | 1910.333 Electrical - Selection and Use of Work Practices OSHA citation code: 19100333 B02 I | Serious | 1 | 8 | $0 | $0 | Sep 30, 2002 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 1 | 2 | $1,125 | $730 | Sep 24, 2002 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 21, 1999#116195694Apr 21, 1999Planned (H) · No Inspection scope, Safety#116195694$00 viol.0 violations$0 in penalties
Inspection #116195694
Dates
- Opened
- Apr 21, 1999
- Closing Conference Date
- Apr 21, 1999
- Closed
- Apr 22, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 130
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 441 E. Market Street, York, PA 17402
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jul 28, 1998#116199639Jul 28, 1998Planned (H) · Complete scope, Health#116199639$2,3005 viol.5 violations$2,300 in penalties
Inspection #116199639
Dates
- Opened
- Jul 28, 1998
- Closing Conference Date
- Jul 30, 1998
- Closed
- Sep 8, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $2,300
- Site Address
- 441 East Market Street, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IIB2 | Serious | 1 | 3 | $1,500 | $900 | Aug 20, 1998 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Serious | 1 | 8 | $1,125 | $700 | Aug 27, 1998 | - | - |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 80 | $1,125 | $700 | Aug 27, 1998 | - | - |
| 02001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 M02 II | Other | 1 | 100 | $0 | $0 | Sep 4, 1998 | - | - |
| 02002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Other | 1 | 150 | $0 | $0 | Sep 4, 1998 | - | - |
Jul 28, 1998#116199324Jul 28, 1998Planned (H) · Complete scope, Safety#116199324$5,75019 viol.19 violations$5,750 in penalties
Inspection #116199324
Dates
- Opened
- Jul 28, 1998
- Closing Conference Date
- Jul 30, 1998
- Contested
- Sep 9, 1998
- Final Order
- Feb 22, 1999
- Closed
- Sep 29, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 11 serious, 8 other-than-serious
- Initial Penalties
- $9,580
- Penalties on Record
- $5,750
- Site Address
- 441 East Market Street, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 2 | $1,500 | $900 | Sep 19, 1998 | Sep 9, 1998 | Feb 22, 1999 |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | 4 | $1,500 | $900 | Sep 19, 1998 | Sep 9, 1998 | Feb 22, 1999 |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 2 | 5 | $1,125 | $675 | Aug 30, 1998 | Sep 9, 1998 | Feb 22, 1999 |
| 01004 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 10 | $1,125 | $675 | Aug 30, 1998 | Sep 9, 1998 | Feb 22, 1999 |
| 01005A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B02 | Serious | 1 | 15 | $1,875 | $1,125 | Sep 30, 1999 | Sep 9, 1998 | Feb 22, 1999 |
Showing the 5 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 19, 1992#102701760Mar 19, 1992Complaint (B) · Partial scope, Health#102701760$5,50018 viol.18 violations$5,500 in penalties
Inspection #102701760
Dates
- Opened
- Mar 19, 1992
- Closing Conference Date
- Apr 24, 1992
- Closed
- Oct 19, 1992
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 59
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 18
- Violation Types
- 8 serious, 10 other-than-serious
- Initial Penalties
- $7,875
- Penalties on Record
- $5,500
- Site Address
- 829 Loucks Mill Road, York, PA 17405
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (5 of 18 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A02 | Serious | 1 | 59 | $1,125 | $780 | May 15, 1992 | - | - |
| 01002 | 1910.24 Step Bolts and Manhole Steps OSHA citation code: 19100024 E | Serious | 1 | 7 | $1,500 | $1,050 | May 30, 1992 | - | - |
| 01003A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 4 | 4 | $2,625 | $1,840 | Jun 30, 1992 | - | - |
| 01003B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I05 | Serious | 1 | 4 | $0 | $0 | Jun 30, 1992 | - | - |
| 01003C | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 K02 | Serious | 6 | 7 | $0 | $0 | Jun 30, 1992 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Oct 6, 1983#12547519Oct 6, 1983Planned (H) · Complete scope, Safety#12547519$15012 viol.12 violations$150 in penalties
Inspection #12547519
Dates
- Opened
- Oct 6, 1983
- Closing Conference Date
- Oct 6, 1983
- Closed
- Nov 2, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 130
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 3 serious, 9 other-than-serious
- Initial Penalties
- $300
- Penalties on Record
- $150
- Site Address
- 441 East Market, York, PA 17403
- Industry
- 332618 Other Fabricated Wire Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A06 | Serious | 1 | - | $120 | $60 | Nov 16, 1983 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | - | $60 | $30 | Nov 16, 1983 | - | - |
| 01003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B02 | Serious | 250 | - | $120 | $60 | Jan 16, 1984 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | - | $0 | $0 | Oct 17, 1983 | - | - |
| 02002 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A02 | Other | 1 | - | $0 | $0 | Oct 21, 1983 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
11 inspections, 1974 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: spring and wire product manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.7%; NAICS 33261 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source