Skip to content
SafetyRecord logoSafetyRecord
MUTH ELECTRIC, INC.
$3,000
penalties
7
viol.
4
insp.

MUTH ELECTRIC, INC.

29120 HOLLY ROAD, PIERRE, SD 57501

Inspections
4
Apr 1986 to Sep 1999 · 4 safety, 0 health
Violations
7
across 4 inspections
Penalties on record
$3,000
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 14, 1999Planned (H) · Partial scope, Safety#102760881$00 viol.

Inspection #102760881

Dates

Opened
Sep 14, 1999
Closing Conference Date
Sep 14, 1999
Closed
Sep 17, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1100 Buchanan, Pierre, SD 57501
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 8, 1996Planned (H) · Complete scope, Safety#113324057$00 viol.

Inspection #113324057

Dates

Opened
Feb 8, 1996
Closing Conference Date
Feb 8, 1996
Closed
Feb 14, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
29120 Holly Road, Pierre, SD 57501
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 5, 1995FatalityAccident (A) · Complete scope, Safety#113326060$3,0004 viol.

Inspection #113326060

Dates

Opened
Sep 5, 1995
Closing Conference Date
Sep 5, 1995
Closed
Oct 30, 1995

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
No
Number of Employees
2
Related Activity
1 accident

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$0
Penalties on Record
$3,000
Site Address
Pierre Regional Airport, Pierre, SD 57501
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityAug 29, 1995

Electric shock - direct contact with energized parts

Injury: Electric ShockBody part: Other Body SystemSource: Electrical Apparatus/WiringEvent: Shock

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1926.417
Electrical - Lockout and Tagging of Circuits (Construction)
OSHA citation code: 19260417 D02 II
Serious12$0$3,000Sep 21, 1995--
01001C1926.417
Electrical - Lockout and Tagging of Circuits (Construction)
OSHA citation code: 19260417 D03 I
Serious12$0$0Sep 21, 1995--
01001D1926.417
Electrical - Lockout and Tagging of Circuits (Construction)
OSHA citation code: 19260417 D04 I
Serious12$0$0Sep 21, 1995--
01001E1926.417
Electrical - Lockout and Tagging of Circuits (Construction)
OSHA citation code: 19260417 D04 II
Serious12$0$0Sep 21, 1995--
Apr 29, 1986Planned (H) · Complete scope, Safety#100843051$03 viol.

Inspection #100843051

Dates

Opened
Apr 29, 1986
Closing Conference Date
Apr 29, 1986
Closed
Jun 4, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
St. Charles Hotel - Capitol & Euclid Avenue, Pierre, SD 57501
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.400
Introduction (Electrical - Construction)
OSHA citation code: 19260400 C01
Other12$0$0May 12, 1986--
010021926.401
OSHA citation code: 19260401 C
Other12$0$0May 12, 1986--
010031926.401
OSHA citation code: 19260401 J01
Other22$0$0May 12, 1986--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.417Electrical - Lockout and Tagging of Circuits (Construction)4 citations · $3,000
1926.4012 citations · $0
1926.400Introduction (Electrical - Construction)1 citation · $0

Other inspected employers in PIERRE, SD