Skip to content
SafetyRecord logoSafetyRecord
CRESCENT BRASS MANUFACTURING CORPORATION
$8,639
penalties
39
viol.
7
insp.

CRESCENT BRASS MANUFACTURING CORPORATION

701 PARK AVENUE, READING, PA 19611NAICS 331524 Aluminum Foundries (except Die-Casting)

Inspections
7
Aug 1988 to Jan 2014 · 2 safety, 5 health
Violations
39
across 7 inspections
Penalties on record
$8,639
latest amounts in DOL records
By classification
Serious 22Willful 0Repeat 0Other 17

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 7, 2014Complaint (B) · Partial scope, Health#339538019$3,6344 viol.

Inspection #339538019

Dates

Opened
Jan 7, 2014
Closing Conference Date
Jan 7, 2014
Final Order
Jun 6, 2014
Closed
Jan 7, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
19
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$4,845
Penalties on Record
$3,634
Site Address
701 Park Avenue, Reading, PA 19611
Industry
331522

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious12$1,360$1,020Jun 17, 2014-Jun 6, 2014
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B07 I
Serious12$2,040$1,530Jun 17, 2014-Jun 6, 2014
010031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 G05
Serious11$1,445$1,084-Jun 6, 2014
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Other13$0$0Jun 11, 2014-Jun 6, 2014
Oct 3, 2007Planned (H) · Complete scope, Health#310840202$03 viol.

Inspection #310840202

Dates

Opened
Oct 3, 2007
Closing Conference Date
Oct 3, 2007
Closed
Jan 7, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
701 Park Avenue, Reading, PA 19611
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other11$0$0Dec 12, 2007--
010021910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Other11$0$0Dec 12, 2007--
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L06
Other11$0$0Dec 12, 2007--
May 3, 2000Planned (H) · Complete scope, Safety#116213083$3254 viol.

Inspection #116213083

Dates

Opened
May 3, 2000
Closing Conference Date
May 4, 2000
Closed
Jun 13, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$500
Penalties on Record
$325
Site Address
701 Park Avenue, Reading, PA 19611
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.184
Slings
OSHA citation code: 19100184 E01
Serious12$500$325Jun 20, 2000--
01001B1910.184
Slings
OSHA citation code: 19100184 E02 II
Serious12$0$0Jun 20, 2000--
01001C1910.184
Slings
OSHA citation code: 19100184 E03 I
Serious12$0$0Jun 20, 2000--
020011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Other130$0$0Jun 20, 2000--
May 3, 2000Planned (H) · Complete scope, Health#113749766$3,96521 viol.

Inspection #113749766

Dates

Opened
May 3, 2000
Closing Conference Date
Jun 16, 2000
Closed
Mar 19, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
21
Violation Types
13 serious, 8 other-than-serious
Initial Penalties
$6,650
Penalties on Record
$3,965
Site Address
701 Park Avenue, Reading, PA 19611
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)80mg/m³
Beryllium and Beryllium Compounds (as Be)80mg/m³
Chromium, Metal and Insoluble Salts80 - 0.0049mg/m³
Cobalt, Metal, Dust and Fume (as Co)80 - 0.000287mg/m³
Copper Fume (as Cu)80 - 0.2294mg/m³
Iron Oxide Fume80 - 0.3829mg/m³
Lead, Inorganic (as Pb)80 - 0.2921mg/m³
Manganese Fume (as Mn)80 - 0.0077mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)80mg/m³
Nickel, Metal and Insoluble compounds (as Ni)80 - 0.009mg/m³
Vanadium fume (as V2O5)80mg/m³
Zinc Oxide Fume80 - 2.646mg/m³

Violations

Violation list (7 of 21 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Other24$525$0Jul 30, 2000--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Other24$0$0Jun 30, 2001--
01001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Other24$0$0Jun 30, 2001--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious24$700$455Jul 30, 2000--
01002B1910.1025
Lead
OSHA citation code: 19101025 C02
Serious24$0$0Jun 30, 2001--
01002C1910.1025
Lead
OSHA citation code: 19101025 E01
Serious24$0$0Jun 30, 2001--
01003A1910.1025
Lead
OSHA citation code: 19101025 D06 II
Serious24$700$455Jul 30, 2000--

Showing the 7 violations listed first by citation identifier. This inspection has 21 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 13, 1995Planned (H) · Complete scope, Safety#123182719$3752 viol.

Inspection #123182719

Dates

Opened
Oct 13, 1995
Closing Conference Date
Oct 13, 1995
Closed
Nov 9, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$375
Penalties on Record
$375
Site Address
701 Park Avenue, Reading, PA 19611
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$375$375Nov 11, 1995--
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other31$0$0Nov 11, 1995--
Nov 3, 1992Planned (H) · No Inspection scope, Health#102704731$00 viol.

Inspection #102704731

Dates

Opened
Nov 3, 1992
Closing Conference Date
Nov 3, 1992
Closed
Nov 9, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
20 Angelica Street & Park Avenue, Reading, PA 19611
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 18, 1988Planned (H) · Complete scope, Health#100502160$3405 viol.

Inspection #100502160

Dates

Opened
Aug 18, 1988
Closing Conference Date
Dec 16, 1988
Closed
Mar 2, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$540
Penalties on Record
$340
Site Address
301 South 7th Street, Reading, PA 19602
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)120mg/m³
Beryllium and Beryllium Compounds (as Be)100mg/m³
Cadmium Fume (as Cd)120 - 0.0072mg/m³
Chromium, Metal and Insoluble Salts120 - 0.0032mg/m³
Cobalt, Metal, Dust and Fume (as Co)120mg/m³
Copper Fume (as Cu)120 - 0.8344mg/m³
Iron Oxide Fume120 - 0.15mg/m³
Lead, Inorganic (as Pb)120 - 0.387mg/m³
Manganese Fume (as Mn)120 - 0.0027mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)120mg/m³
Nickel, Metal and Insoluble compounds (as Ni)120 - 0.0154mg/m³
Particulates not otherwise regulated (Respirable Fraction)100mg/m³
Vanadium fume (as V2O5)120mg/m³
Zinc Oxide Fume120 - 2.7mg/m³

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious13$180$80Jan 30, 1989--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious21$360$260Feb 8, 1989--
020011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G07 IIIC
Other130$0$0Feb 8, 1989--
020021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 M02 IIE
Other130$0$0Feb 8, 1989--
020031910.1025
Lead
OSHA citation code: 19101025 D07
Other11$0$0Jan 26, 1989--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead15 citations · $3,185
1910.134Respiratory Protection4 citations · $455
1910.184Slings3 citations · $325

Chemical exposure sampling

Samples
260
Substances
14
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer5.6
Industry average3.1
Penalties per inspection
This employer$1,234
Industry average$2,943

Primary Metal Manufacturing, 9,284 employers with OSHA inspections. Arithmetic from DOL records.