Skip to content
SafetyRecord logoSafetyRecord
DELTA FIBERGLASS STRUCTURES, INC.
$9,175
penalties
55
viol.
8
insp.

DELTA FIBERGLASS STRUCTURES, INC.

2301 HUTSON RD., GREEN BAY, WI 54303

Inspections
8
Jan 1991 to May 1996 · 5 safety, 3 health
Violations
55
across 8 inspections
Penalties on record
$9,175
latest amounts in DOL records
By classification
Serious 43Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 15, 1996Follow-Up (F) · Partial scope, Health#114154412$00 viol.

Inspection #114154412

Dates

Opened
May 15, 1996
Closing Conference Date
May 15, 1996
Closed
Jun 20, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Styrene118.0727 - 177.8509ppm
Oct 5, 1995Complaint (B) · Complete scope, Safety#114157522$2,67512 viol.

Inspection #114157522

Dates

Opened
Oct 5, 1995
Closing Conference Date
Oct 5, 1995
Closed
Jun 7, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 complaint

Violations and Penalties

Total Violations
12
Violation Types
6 serious, 6 other-than-serious
Initial Penalties
$8,850
Penalties on Record
$2,675
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVA
Serious12$1,400$200Nov 2, 1995--
010021910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious11$1,400$700Nov 2, 1995--
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 C01
Other123$1,400$0Dec 14, 1995--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$1,500$525Oct 31, 1995--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$1,050$525Nov 9, 1995--
010061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$1,050$525Nov 2, 1995--

Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 5, 1995Complaint (B) · Complete scope, Health#114154255$1,8504 viol.

Inspection #114154255

Dates

Opened
Oct 5, 1995
Closing Conference Date
Oct 12, 1995
Closed
Jun 20, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$4,550
Penalties on Record
$1,850
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acetone49.9142 - 51.7675ppm
Styrene418.8464 - 274.8737ppm

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.28
Duty to Have Fall Protection
OSHA citation code: 19100028 A01
Serious14$1,750$750Nov 9, 1995--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious14$1,400$400Nov 9, 1995--
02001A1910.1000
Air Contaminants
OSHA citation code: 19101000 B01
Serious14$1,400$700Feb 7, 1996--
02001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious14$0$0Feb 7, 1996--
Apr 26, 1993Monitoring (D) · Partial scope, Safety#106506777$01 viol.

Inspection #106506777

Dates

Opened
Apr 26, 1993
Closing Conference Date
Apr 26, 1993
Closed
Jun 3, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other117$0$0May 25, 1993--
Mar 12, 1992Follow-Up (F) · Partial scope, Safety#106503543$4002 viol.

Inspection #106503543

Dates

Opened
Mar 12, 1992
Closing Conference Date
Mar 12, 1992
Closed
Jul 7, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$900
Penalties on Record
$400
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.94
Ventilation
OSHA citation code: 19100094 C04 IV
Serious110$900$400Jul 6, 1993--
01001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 M01
Serious110$0$0Jul 6, 1993--
Jun 12, 1991Follow-Up (F) · Partial scope, Safety#106505183$00 viol.

Inspection #106505183

Dates

Opened
Jun 12, 1991
Closing Conference Date
Jun 12, 1991
Closed
Jun 17, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 9, 1991Complaint (B) · Complete scope, Health#103055117$2,05019 viol.

Inspection #103055117

Dates

Opened
Jan 9, 1991
Closing Conference Date
Jan 18, 1991
Closed
Sep 25, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27
Related Activity
2 complaints

Violations and Penalties

Total Violations
19
Violation Types
17 serious, 2 other-than-serious
Initial Penalties
$3,640
Penalties on Record
$2,050
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acetone2111.3858 - 99.5904ppm
Antimony and Compounds (as Sb)70 - 0.0568mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Cadmium Fume (as Cd)70 - 0.006mg/m³
Chromium, Metal and Insoluble Salts70 - 0.0122mg/m³
Cobalt, Metal, Dust and Fume (as Co)70 - 0.0149mg/m³
Copper Fume (as Cu)70 - 0.009mg/m³
Iron Oxide Fume70 - 0.0891mg/m³
Lead, Inorganic (as Pb)70mg/m³
Manganese Fume (as Mn)70 - 0.0021mg/m³
Methyl Ethyl Ketone Peroxide40mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)70mg/m³
Nickel, Metal and Insoluble compounds (as Ni)70mg/m³
Styrene2110.1505 - 205.6733ppm
Vanadium fume (as V2O5)70mg/m³
Zinc Oxide Fume70 - 0.0056mg/m³

Violations

Violation list (6 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious22$420$250May 6, 1991--
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious11$350$200Sep 25, 1991--
010031910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q02
Serious110$280$200Mar 5, 1991--
010041910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious14$350$200Feb 19, 1991--
01005A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious11$280$200Mar 5, 1991--
01005B1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Serious110$0$0Mar 5, 1991--

Showing the 6 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 9, 1991Complaint (B) · Complete scope, Safety#103052569$2,20017 viol.

Inspection #103052569

Dates

Opened
Jan 9, 1991
Closing Conference Date
Jan 10, 1991
Closed
Mar 31, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27
Related Activity
1 complaint

Violations and Penalties

Total Violations
17
Violation Types
14 serious, 3 other-than-serious
Initial Penalties
$3,640
Penalties on Record
$2,200
Site Address
2301 Hutson Rd., Green Bay, WI 54303
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.29
Fall Protection Systems and Criteria
OSHA citation code: 19100029 A03 V
Serious13$350$200Mar 5, 1991--
01002A1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious13$350$200May 6, 1991--
01002B1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious13$0$0Mar 5, 1991--
01002C1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious13$0$0May 6, 1991--
01002D1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 III
Serious13$0$0May 6, 1991--
01002E1910.106
Flammable Liquids
OSHA citation code: 19100106 D04 IV
Serious13$0$0May 6, 1991--

Showing the 6 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.106Flammable Liquids10 citations · $1,550
1910.1000Air Contaminants8 citations · $1,200
1910.134Respiratory Protection4 citations · $200

Chemical exposure sampling

Samples
155
Substances
16
Inspections
3

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in GREEN BAY, WI