Skip to content
SafetyRecord logoSafetyRecord
PERFECTION MOULDERS
$3,900
penalties
52
viol.
9
insp.

PERFECTION MOULDERS

213 CONNELL STREET, GOODLETTSVILLE, TN 37072

Inspections
9
Jan 1985 to Jan 2010 · 7 safety, 2 health
Violations
52
across 9 inspections
Penalties on record
$3,900
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 40

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 27, 2010Planned (H) · Complete scope, Safety#314124546$5003 viol.

Inspection #314124546

Dates

Opened
Jan 27, 2010
Closing Conference Date
Jan 27, 2010
Closed
May 28, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$500
Penalties on Record
$500
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious11$500$500Jun 3, 2010--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IB
Serious11$0$0Jun 3, 2010--
0200190007Other12$0$0Jun 3, 2010--
May 31, 2006Planned (H) · Complete scope, Safety#309927879$1,1005 viol.

Inspection #309927879

Dates

Opened
May 31, 2006
Closing Conference Date
May 31, 2006
Closed
Aug 22, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 4 other-than-serious
Initial Penalties
$1,100
Penalties on Record
$1,100
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$1,000$1,000Aug 7, 2006--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A02
Other11$100$100Aug 7, 2006--
02002A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0Jul 19, 2006--
02002B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other11$0$0Jul 19, 2006--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0Jul 19, 2006--
May 9, 1996Planned (H) · Complete scope, Safety#300449162$35011 viol.

Inspection #300449162

Dates

Opened
May 9, 1996
Closing Conference Date
May 9, 1996
Closed
Oct 14, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
11
Violation Types
2 serious, 9 other-than-serious
Initial Penalties
$950
Penalties on Record
$350
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Other11$250$0Jun 21, 1996--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$350$350Jun 21, 1996--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious22$350$0Jun 21, 1996--
020011910.106
Flammable Liquids
OSHA citation code: 19100106 D05 III
Other11$0$0Jun 21, 1996--
020021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Other11$0$0Jun 21, 1996--

Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 9, 1996Planned (H) · Complete scope, Safety#300449154$00 viol.

Inspection #300449154

Dates

Opened
May 9, 1996
Closing Conference Date
May 9, 1996
Closed
Jun 30, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 27, 1994Follow-Up (F) · Partial scope, Health#114509599$00 viol.

Inspection #114509599

Dates

Opened
May 27, 1994
Closing Conference Date
May 27, 1994
Closed
Jun 2, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 6, 1993Planned (H) · Complete scope, Health#114510381$1,2008 viol.

Inspection #114510381

Dates

Opened
May 6, 1993
Closing Conference Date
May 6, 1993
Closed
Jun 2, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 5 other-than-serious
Initial Penalties
$2,700
Penalties on Record
$1,200
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious15$1,200$600May 25, 1994--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I02 IIA
Serious15$0$0Jul 29, 1993--
010021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious15$1,200$600Sep 27, 1993--
020011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other19$0$0Aug 28, 1993--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other118$150$0Aug 28, 1993--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 2, 1993Planned (H) · Complete scope, Safety#114492291$75018 viol.

Inspection #114492291

Dates

Opened
Feb 2, 1993
Closing Conference Date
Feb 2, 1993
Closed
May 17, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
18
Violation Types
4 serious, 14 other-than-serious
Initial Penalties
$750
Penalties on Record
$750
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$150$150Mar 14, 1993--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Serious22$150$150Apr 13, 1993--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious33$150$150Mar 14, 1993--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$100$100Mar 14, 1993--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other210$0$0Mar 14, 1993--

Showing the 5 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 16, 1989Planned (H) · Complete scope, Safety#107905358$03 viol.

Inspection #107905358

Dates

Opened
Aug 16, 1989
Closing Conference Date
Aug 16, 1989
Closed
Oct 2, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0Sep 29, 1989--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other11$0$0Sep 29, 1989--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other11$0$0Sep 29, 1989--
Jan 8, 1985Planned (H) · Complete scope, Safety#3260890$04 viol.

Inspection #3260890

Dates

Opened
Jan 8, 1985
Closing Conference Date
Jan 8, 1985
Closed
Feb 28, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
213 Connell Street, Goodlettsville, TN 37072
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001300.301Other116$0$0Jan 20, 1985--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other11$0$0Feb 4, 1985--
010031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IV C
Other11$0$0Jan 20, 1985--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other42$0$0Jan 20, 1985--
Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment11 citations · $0
1910.219Mechanical Power-Transmission Apparatus4 citations · $1,250
1910.95Occupational Noise Exposure3 citations · $1,200

Industry comparison

BLS 2024 survey: aluminum foundries (except die-casting) reported 5.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.4%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in GOODLETTSVILLE, TN

All employers in GOODLETTSVILLE →