Skip to content
SafetyRecord logoSafetyRecord
HUSTON ELECTRIC INC
$3,026
penalties
41
viol.
25
insp.

HUSTON ELECTRIC INC

(ONCOLOGY BUILDING) 420 NORTH 26TH STREET, LAFAYETTE, IN 47905

Inspections
25
Jul 1986 to Oct 2014 · 25 safety, 0 health
Violations
41
across 25 inspections
Penalties on record
$3,026
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 1Other 34

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 4, 2003Planned (H) · Partial scope, Safety#306003369$00 viol.

Inspection #306003369

Dates

Opened
Mar 4, 2003
Closing Conference Date
Mar 18, 2003
Closed
Jun 9, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
1

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Taco Bell Jobsite, Lafayette, IN 47901
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 21, 2002Planned (H) · Complete scope, Safety#305921041$01 viol.

Inspection #305921041

Dates

Opened
Nov 21, 2002
Closing Conference Date
Nov 25, 2002
Closed
Mar 26, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Wea Ridge Middle School, Lafayette, IN 47902
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Other114$0$0Mar 5, 2003--
Oct 10, 2002Planned (H) · Complete scope, Safety#305645822$6001 viol.

Inspection #305645822

Dates

Opened
Oct 10, 2002
Closing Conference Date
Oct 18, 2002
Closed
Mar 25, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
16

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,200
Penalties on Record
$600
Site Address
Holiday Inn Select Hotel -, Lafayette, IN 47901
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious13$1,200$600Jan 31, 2003--
May 15, 2002Planned (H) · Complete scope, Safety#305201766$1,5006 viol.

Inspection #305201766

Dates

Opened
May 15, 2002
Closing Conference Date
Jun 5, 2002
Closed
Sep 17, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
8

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$4,000
Penalties on Record
$1,500
Site Address
Wea Ridge Middle School, Lafayette, IN 47902
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E01 I
Other15$1,600$0Aug 23, 2002--
01001B1926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E01 II
Other15$0$0Aug 23, 2002--
01001C1926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E01 III
Other15$0$0Aug 23, 2002--
01001D1926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E08 III
Other15$0$0Aug 23, 2002--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious15$1,200$750Aug 23, 2002--

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 29, 2001Planned (H) · Complete scope, Safety#304050883$01 viol.

Inspection #304050883

Dates

Opened
May 29, 2001
Closing Conference Date
Jun 1, 2001
Closed
Jan 4, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
700 S 4th Street, Lafayette, IN 47905
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other15$0$0Nov 7, 2001--
Feb 1, 2001Planned (H) · Complete scope, Safety#127451771$00 viol.

Inspection #127451771

Dates

Opened
Feb 1, 2001
Closing Conference Date
Feb 9, 2001
Closed
May 2, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(tippecanoe County Branch Library)3101 S Creasy Ln, Lafayette, IN 47904
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 21, 1998Planned (H) · Complete scope, Safety#114958234$3004 viol.

Inspection #114958234

Dates

Opened
Apr 21, 1998
Closing Conference Date
Apr 24, 1998
Closed
Oct 30, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5

Violations and Penalties

Total Violations
4
Violation Types
1 repeat, 3 other-than-serious
Initial Penalties
$300
Penalties on Record
$300
Site Address
(wea Ridge Elem Sch) 1333 E. Cr 430 S, Lafayette, IN 47905
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat14$300$300Aug 19, 1998--
020011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other34$0$0Aug 19, 1998--
020021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 II
Other14$0$0Aug 19, 1998--
020031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 V
Other14$0$0Aug 19, 1998--
Jan 26, 1998Planned (H) · Complete scope, Safety#125413757$03 viol.

Inspection #125413757

Dates

Opened
Jan 26, 1998
Closing Conference Date
Jan 27, 1998
Closed
Jul 16, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(oncology Building) 420 North 26th Street, Lafayette, IN 47905
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other11$0$0Jun 6, 1998--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Other11$0$0Jun 6, 1998--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other12$0$0Jun 6, 1998--
Oct 24, 1995Planned (H) · Complete scope, Safety#123983652$03 viol.

Inspection #123983652

Dates

Opened
Oct 24, 1995
Closing Conference Date
Oct 25, 1995
Closed
Dec 8, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
13

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(wastewater Treatment) S. River Road, Lafayette, IN 47905
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.59
Hazard Communication
OSHA citation code: 19260059 E01 I
Other17$0$0Dec 7, 1995--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Other12$0$0Dec 4, 1995--
010031926.1060
Stairways and Ladders - Training (Construction)
OSHA citation code: 19261060 A
Other17$0$0Dec 7, 1995--
Aug 7, 1995Planned (H) · Complete scope, Safety#124022344$00 viol.

Inspection #124022344

Dates

Opened
Aug 7, 1995
Closing Conference Date
Aug 11, 1995
Closed
Sep 11, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(railroad Depot) 200 N. 2nd Street, Lafayette, IN 47901
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 11 to 20 of 25, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)11 citations · $1,863
1926.404Electrical - Wiring Design and Protection (Construction)6 citations · $1,163
1926.251Rigging Equipment for Material Handling4 citations · $0

Industry comparison

BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in LAFAYETTE, IN