Skip to content
SafetyRecord logoSafetyRecord
PAPER ART COMPANY INC
$3,485
penalties
39
viol.
6
insp.

PAPER ART COMPANY INC

3500 N ARLINGTON, INDIANAPOLIS, IN 46218

Inspections
6
Apr 1985 to Jun 1993 · 5 safety, 1 health
Violations
39
across 6 inspections
Penalties on record
$3,485
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 3Other 24

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 28, 1993Complaint (B) · Complete scope, Safety#114988801$1,80012 viol.

Inspection #114988801

Dates

Opened
Jun 28, 1993
Closing Conference Date
Jun 28, 1993
Contested
Sep 3, 1993
Final Order
Mar 17, 1995
Closed
Apr 6, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
150
Related Activity
1 complaint

Violations and Penalties

Total Violations
12
Violation Types
4 serious, 8 other-than-serious
Initial Penalties
$4,950
Penalties on Record
$1,800
Site Address
3500 N Arlington, Indianapolis, IN 46218
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (8 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious618$2,250$1,125Aug 22, 1993Sep 3, 1993Mar 17, 1995
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Other16$1,350$0Aug 22, 1993Sep 3, 1993Mar 17, 1995
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Other16$0$0Aug 22, 1993Sep 3, 1993Mar 17, 1995
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious14$1,350$675Aug 22, 1993Sep 3, 1993Mar 17, 1995
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious14$0$0Aug 22, 1993Sep 3, 1993Mar 17, 1995
01003C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious14$0$0Aug 22, 1993Sep 3, 1993Mar 17, 1995
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other319$0$0Aug 8, 1993Sep 3, 1993Mar 17, 1995
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 G02
Other16$0$0Aug 8, 1993Sep 3, 1993Mar 17, 1995

Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 26, 1992Complaint (B) · Complete scope, Safety#115018814$8753 viol.

Inspection #115018814

Dates

Opened
Oct 26, 1992
Closing Conference Date
Oct 26, 1992
Closed
Jan 27, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
75
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$875
Penalties on Record
$875
Site Address
2525 North Shadeland, Indianapolis, IN 46206
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious11$525$525Jan 4, 1993--
02001400.302Other110$350$350Jan 7, 1993--
020021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other175$0$0Jan 5, 1993--
Nov 30, 1988Complaint (B) · Partial scope, Health#104071014$01 viol.

Inspection #104071014

Dates

Opened
Nov 30, 1988
Closing Conference Date
Nov 30, 1988
Closed
Aug 7, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
115
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2525 North Shadeland, Indianapolis, IN 46206
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other180$0$0Mar 6, 1989--
Jun 8, 1987Follow-Up (F) · Partial scope, Safety#103932778$00 viol.

Inspection #103932778

Dates

Opened
Jun 8, 1987
Closing Conference Date
Jun 8, 1987
Closed
Jun 12, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
261

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3500 N Arlington, Indianapolis, IN 46218
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 25, 1987Planned (H) · Complete scope, Safety#104033428$45010 viol.

Inspection #104033428

Dates

Opened
Mar 25, 1987
Closing Conference Date
Mar 25, 1987
Closed
Jun 12, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
261

Violations and Penalties

Total Violations
10
Violation Types
1 serious, 3 repeat, 6 other-than-serious
Initial Penalties
$900
Penalties on Record
$450
Site Address
3500 N Arlington, Indianapolis, IN 46218
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious14$270$270May 12, 1987--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Repeat11$540$90Apr 16, 1987--
02002A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Repeat610$90$90Apr 22, 1987--
02002B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Repeat610$0$0Apr 22, 1987--
030011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other31$0$0May 12, 1987--
030021910.23
Ladders
OSHA citation code: 19100023 C01
Other31$0$0May 12, 1987--
030031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other14$0$0Apr 16, 1987--
030041910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B04 IXC
Other14$0$0May 12, 1987--

Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Apr 3, 1985Planned (H) · Complete scope, Safety#14708812$36013 viol.

Inspection #14708812

Dates

Opened
Apr 3, 1985
Closing Conference Date
Apr 4, 1985
Closed
Jun 3, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
206

Violations and Penalties

Total Violations
13
Violation Types
6 serious, 7 other-than-serious
Initial Penalties
$720
Penalties on Record
$360
Site Address
3500 N Arlington Ave, Indianapolis, IN 46218
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious13$180$90May 28, 1985--
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious12$180$90May 28, 1985--
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious12$0$0May 28, 1985--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious24$180$90May 28, 1985--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious24$0$0May 28, 1985--
010041910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious12$180$90Apr 29, 1985--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A03
Other14$0$0Apr 29, 1985--
020021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q02
Other18$0$0Apr 29, 1985--

Showing the 8 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.304Electrical - Wiring Design and Protection6 citations · $615
1910.219Mechanical Power-Transmission Apparatus5 citations · $765
1910.305Electrical - Wiring Methods, Components, and Equipment5 citations · $0

Other inspected employers in INDIANAPOLIS, IN

All employers in INDIANAPOLIS →