Skip to content
SafetyRecord logoSafetyRecord
STEINBERGER CONSTRUCTION CO INC
$3,375
penalties
18
viol.
3
insp.

STEINBERGER CONSTRUCTION CO INC

(GARAGE) CLEVELAND & FT WAYNE ST, WARSAW, IN 46580

Inspections
3
Oct 1987 to Jan 1992 · 3 safety, 0 health
Violations
18
across 3 inspections
Penalties on record
$3,375
latest amounts in DOL records
By classification
Serious 2Willful 0Repeat 1Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 7, 1992Planned (H) · Complete scope, Safety#114999576$3,3756 viol.

Inspection #114999576

Dates

Opened
Jan 7, 1992
Closing Conference Date
Jan 8, 1992
Closed
Apr 16, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 1 repeat, 3 other-than-serious
Initial Penalties
$4,500
Penalties on Record
$3,375
Site Address
(zimmer Plant #5) Boggs Industrial Park, Warsaw, IN 46580
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.350
Gas Welding and Cutting
OSHA citation code: 19260350 H
Serious14$1,200$900Feb 28, 1992--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious14$900$675Feb 28, 1992--
020011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat24$2,400$1,800Feb 28, 1992--
030011926.302
Power-Operated Hand Tools
OSHA citation code: 19260302 B07
Other14$0$0Feb 29, 1992--
030021926.1052
Stairways (Construction)
OSHA citation code: 19261052 A04
Other14$0$0Feb 28, 1992--
030031926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other14$0$0Feb 28, 1992--
Dec 17, 1987Follow-Up (F) · Partial scope, Safety#103984324$00 viol.

Inspection #103984324

Dates

Opened
Dec 17, 1987
Closing Conference Date
Dec 17, 1987
Closed
Mar 22, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
(garage) Cleveland & Ft Wayne St, Warsaw, IN 46580
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 15, 1987Planned (H) · Complete scope, Safety#103986006$012 viol.

Inspection #103986006

Dates

Opened
Oct 15, 1987
Closing Conference Date
Oct 15, 1987
Closed
Mar 22, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
12
Violation Types
12 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
(garage) Cleveland & Ft Wayne St, Warsaw, IN 46580
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.54
Nonionizing Radiation
OSHA citation code: 19260054 I
Other11$0$0Nov 10, 1987--
010021926.152
Flammable Liquids
OSHA citation code: 19260152 A01
Other11$0$0Nov 10, 1987--
010031926.152
Flammable Liquids
OSHA citation code: 19260152 G09
Other11$0$0Nov 10, 1987--
010041926.152
Flammable Liquids
OSHA citation code: 19260152 G11
Other11$0$0Nov 10, 1987--
010051926.350
Gas Welding and Cutting
OSHA citation code: 19260350 A09
Other11$0$0Nov 10, 1987--
010061926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 G
Other11$0$0Nov 12, 1987--
010071926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 I02 I
Other11$0$0Nov 10, 1987--
010081926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Other11$0$0Nov 10, 1987--
010091926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other22$0$0Nov 10, 1987--
010101926.550
Cranes and Derricks
OSHA citation code: 19260550 A04
Other11$0$0Nov 10, 1987--
010111926.550
Cranes and Derricks
OSHA citation code: 19260550 A06
Other11$0$0Nov 12, 1987--
010121926.602
Material Handling Equipment
OSHA citation code: 19260602 A09 I
Other11$0$0Nov 10, 1987--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.152Flammable Liquids3 citations · $0
1926.1052Stairways (Construction)2 citations · $0
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $2,475

Other inspected employers in WARSAW, IN

All employers in WARSAW →