Skip to content
SafetyRecord logoSafetyRecord
DYE PLUMBING & HEATING INC
$5,950
penalties
15
viol.
3
insp.

DYE PLUMBING & HEATING INC

(IN/KOTE) 30755 EDISON ROAD, NEW CARLISLE, IN 46552

Inspections
3
Oct 1988 to Nov 1992 · 3 safety, 0 health
Violations
15
across 3 inspections
Penalties on record
$5,950
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 2Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 16, 1992Planned (H) · Complete scope, Safety#114940927$3,7501 viol.

Inspection #114940927

Dates

Opened
Nov 16, 1992
Closing Conference Date
Nov 17, 1992
Closed
Feb 8, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$5,000
Penalties on Record
$3,750
Site Address
(new Carlisle Sewer Project) Front & Michigan St, New Carlisle, IN 46552
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.652
Excavations - Protection of Employees
OSHA citation code: 19260652 A01
Serious12$5,000$3,750Dec 29, 1992--
Jul 22, 1991Planned (H) · Complete scope, Safety#115007296$1,2005 viol.

Inspection #115007296

Dates

Opened
Jul 22, 1991
Closing Conference Date
Aug 2, 1991
Contested
Jan 10, 1992
Final Order
Apr 30, 1993
Closed
Jun 1, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
10

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 2 repeat, 2 other-than-serious
Initial Penalties
$2,000
Penalties on Record
$1,200
Site Address
(in/Kote) 30755 Edison Road, New Carlisle, IN 46552
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.59
Hazard Communication
OSHA citation code: 19260059 E04
Serious14$400$400Dec 19, 1991Jan 10, 1992Apr 30, 1993
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 IIIA
Other14$600$0Dec 20, 1991Jan 10, 1992Apr 30, 1993
020011926.59
Hazard Communication
OSHA citation code: 19260059 H
Repeat14$800$600Dec 30, 1991Jan 10, 1992Apr 30, 1993
020021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Repeat12$200$200Dec 19, 1991Jan 10, 1992Apr 30, 1993
030011926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 E01 III
Other14$0$0Dec 19, 1991Jan 10, 1992Apr 30, 1993
Oct 4, 1988Planned (H) · Complete scope, Safety#104068978$1,0009 viol.

Inspection #104068978

Dates

Opened
Oct 4, 1988
Closing Conference Date
Oct 4, 1988
Contested
Jan 12, 1989
Final Order
Apr 4, 1989
Closed
Apr 12, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
9
Violation Types
1 serious, 8 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
(mill) 30755 Edison Road, New Carlisle, IN 46552
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A03
Serious12$1,000$1,000Dec 19, 1988Jan 12, 1989Apr 4, 1989
020011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 A
Other11$0$0Dec 19, 1988Jan 12, 1989Apr 4, 1989
020021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other33$0$0Dec 19, 1988Jan 12, 1989Apr 4, 1989
020031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIJ
Other11$0$0Dec 19, 1988Jan 12, 1989Apr 4, 1989
020041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other23$0$0Dec 19, 1988Jan 12, 1989Apr 4, 1989
020051926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 IIID
Other11$0$0Dec 19, 1988Jan 12, 1989Apr 4, 1989
020061926.601
Motor Vehicles
OSHA citation code: 19260601 B03
Other13$0$0Dec 27, 1988Jan 12, 1989Apr 4, 1989
020071926.601
Motor Vehicles
OSHA citation code: 19260601 B04
Other13$0$0Dec 27, 1988Jan 12, 1989Apr 4, 1989
020081926.602
Material Handling Equipment
OSHA citation code: 19260602 A09 I
Other23$0$0Dec 27, 1988Jan 12, 1989Apr 4, 1989
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)3 citations · $0
1926.404Electrical - Wiring Design and Protection (Construction)3 citations · $200
1926.601Motor Vehicles2 citations · $0

Other inspected employers in NEW CARLISLE, IN

All employers in NEW CARLISLE →