ABQ RADIATOR SERVICE
119 TENNESSEE NE, ALBUQUERQUE, NM 87109
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 21, 1999#302270244Sep 21, 1999Referral (C) · Complete scope, Health#302270244$4018 viol.18 violations$40 in penalties
Inspection #302270244
Dates
- Opened
- Sep 21, 1999
- Closing Conference Date
- Sep 21, 1999
- Closed
- Sep 20, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 18
- Violation Types
- 14 serious, 1 repeat, 3 other-than-serious
- Initial Penalties
- $2,080
- Penalties on Record
- $40
- Site Address
- 119 Tennessee Ne, Albuquerque, NM 87109
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (18 of 18 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Repeat | 1 | 1 | $80 | $40 | Mar 20, 2000 | - | - |
| 02001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 1 | $500 | $0 | Apr 10, 2000 | - | - |
| 02002A | 1910.134 Respiratory Protection OSHA citation code: 19100134 C01 | Serious | 1 | 1 | $625 | $0 | Aug 17, 2000 | - | - |
| 02002B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02002C | 1910.134 Respiratory Protection OSHA citation code: 19100134 G01 I | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02003 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 1 | $0 | $0 | Aug 10, 2000 | - | - |
| 02004A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 1 | 1 | $875 | $0 | Aug 17, 2000 | - | - |
| 02004B | 1910.1025 Lead OSHA citation code: 19101025 D07 | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004C | 1910.1025 Lead OSHA citation code: 19101025 E01 | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004D | 1910.1025 Lead OSHA citation code: 19101025 E03 I | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004E | 1910.1025 Lead OSHA citation code: 19101025 F03 I | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004F | 1910.1025 Lead OSHA citation code: 19101025 G01 | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004G | 1910.1025 Lead OSHA citation code: 19101025 I02 I | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004H | 1910.1025 Lead OSHA citation code: 19101025 I03 I | Serious | 1 | 1 | $0 | $0 | Aug 7, 2000 | - | - |
| 02004I | 1910.1025 Lead OSHA citation code: 19101025 J01 I | Other | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004J | 1910.1025 Lead OSHA citation code: 19101025 J02 IB | Serious | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 02004K | 1910.1025 Lead OSHA citation code: 19101025 L01 IV | Other | 1 | 1 | $0 | $0 | Aug 17, 2000 | - | - |
| 03001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Other | 2 | 1 | $0 | $0 | Aug 3, 2000 | - | - |
Sep 18, 1997#115154346Sep 18, 1997Referral (C) · Complete scope, Health#115154346$80020 viol.20 violations$800 in penalties
Inspection #115154346
Dates
- Opened
- Sep 18, 1997
- Closing Conference Date
- Sep 18, 1997
- Closed
- Dec 23, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 1
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 20
- Violation Types
- 8 serious, 12 other-than-serious
- Initial Penalties
- $1,200
- Penalties on Record
- $800
- Site Address
- 119 Tennessee Ne, Albuquerque, NM 87109
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (20 of 20 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B01 | Serious | 1 | 1 | $400 | $400 | Dec 23, 1997 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 1 | 1 | $0 | $0 | Dec 23, 1997 | - | - |
| 01001C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | 1 | $0 | $0 | Dec 2, 1997 | - | - |
| 01001D | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G07 | Other | 1 | 1 | $0 | $0 | Dec 2, 1997 | - | - |
| 01001E | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Other | 1 | 1 | $0 | $0 | Dec 23, 1997 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C06 | Serious | 5 | 1 | $400 | $400 | Dec 23, 1997 | - | - |
| 01002B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 2 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 01002C | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 5 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 01003A | 1910.1025 Lead OSHA citation code: 19101025 D02 | Serious | 1 | 1 | $400 | $0 | Dec 23, 1997 | - | - |
| 01003B | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Serious | 1 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 02001 | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Other | 1 | 1 | $0 | $0 | Nov 7, 1997 | - | - |
| 02002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 1 | 1 | $0 | $0 | Nov 7, 1997 | - | - |
| 02003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 1 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 02004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 II | Other | 1 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 02005 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Other | 1 | 1 | $0 | $0 | Nov 24, 1997 | - | - |
| 02006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 1 | $0 | $0 | Dec 9, 1997 | - | - |
| 02007 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 I | Other | 1 | 1 | $0 | $0 | Dec 9, 1997 | - | - |
| 02008 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Other | 2 | 1 | $0 | $0 | Dec 9, 1997 | - | - |
| 02009 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Other | 1 | 1 | $0 | $0 | Dec 9, 1997 | - | - |
| 02010 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Other | 1 | 1 | $0 | $0 | Dec 9, 1997 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1997 to 1999. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.