Skip to content
SafetyRecord logoSafetyRecord
POLYMICRO TECHNOLOGIES INC
$855
penalties
14
viol.
4
insp.

POLYMICRO TECHNOLOGIES INC

3035 N 33RD DR, PHOENIX, AZ 85017

Inspections
4
Dec 1985 to Nov 2012 · 3 safety, 1 health
Violations
14
across 4 inspections
Penalties on record
$855
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 20, 2012Planned (H) · Complete scope, Safety#316867878$00 viol.

Inspection #316867878

Dates

Opened
Nov 20, 2012
Closing Conference Date
Nov 20, 2012
Closed
Dec 13, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
65

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
18019 N 25th Ave, Phoenix, AZ 85023
Industry
327999 All Other Miscellaneous Nonmetallic Mineral Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Aug 11, 1992Follow-Up (F) · Partial scope, Safety#115571440$00 viol.

Inspection #115571440

Dates

Opened
Aug 11, 1992
Closing Conference Date
Aug 11, 1992
Closed
Aug 18, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
57

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
3035 N 33rd Dr, Phoenix, AZ 85017
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 14, 1992Planned (H) · Complete scope, Safety#115571036$85511 viol.

Inspection #115571036

Dates

Opened
May 14, 1992
Closing Conference Date
May 14, 1992
Closed
Aug 18, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
51

Violations and Penalties

Total Violations
11
Violation Types
3 serious, 8 other-than-serious
Initial Penalties
$1,140
Penalties on Record
$855
Site Address
3035 N 33rd Dr, Phoenix, AZ 85017
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E05 I
Serious12$300$225Jun 19, 1992--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious310$420$315Jun 19, 1992--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious26$420$315Jun 19, 1992--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other12$0$0Jun 19, 1992--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$0$0Jun 19, 1992--
020031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 P06 II
Other12$0$0Jun 19, 1992--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other38$0$0Jun 19, 1992--
020051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other110$0$0Jun 19, 1992--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other39$0$0Jun 19, 1992--
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Other15$0$0Jun 19, 1992--
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other196$0$0Jun 19, 1992--
Dec 17, 1985Planned (H) · Complete scope, Health#2544641$03 viol.

Inspection #2544641

Dates

Opened
Dec 17, 1985
Closing Conference Date
Dec 19, 1985
Closed
Jun 3, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3035 N 33rd Dr, Phoenix, AZ 85017
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Other16$0$0Feb 7, 1986--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other16$0$0Feb 7, 1986--
01003R4130609
OSHA citation code: R4130609 A
Other113$0$0Jan 9, 1986--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $630
1910.219Mechanical Power-Transmission Apparatus2 citations · $225
1910.212General Requirements for All Machines (Machine Guarding)1 citation · $0

Industry comparison

BLS 2024 survey: all other miscellaneous nonmetallic mineral product manufacturing reported 1.7 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 23.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHOENIX, AZ

All employers in PHOENIX →