Nov 16, 2000Planned (H) · Complete scope, Safety#303312813$2005 viol.

Inspection #303312813

Dates

Opened
Nov 16, 2000
Closing Conference Date
Nov 17, 2000
Closed
Jun 21, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
33

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$200
Penalties on Record
$200
Site Address
1376 Nw Conroy St, Madras, OR 97741
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$100$100Nov 17, 2000--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$100$100Nov 17, 2000--
020031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other11$0$0Nov 17, 2000--
020041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIF
Other11$0$0Jan 3, 2001--
02005702037804
OSHA citation code: 702037804 A
Other133$0$0Jan 3, 2001--
Oct 14, 1993Planned (H) · Complete scope, Safety#115779720$3,07512 viol.

Inspection #115779720

Dates

Opened
Oct 14, 1993
Closing Conference Date
Oct 14, 1993
Contested
Dec 2, 1993
Closed
Jun 14, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
26

Violations and Penalties

Total Violations
12
Violation Types
1 serious, 8 repeat, 3 other-than-serious
Initial Penalties
$4,350
Penalties on Record
$3,075
Site Address
1376 Nw Conroy St, Madras, OR 97741
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Dec 2, 1993. Final orders are recorded through Feb 16, 1994. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious33$750$525Nov 29, 1993Dec 2, 1993Feb 16, 1994
020021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Repeat11$600$420Nov 29, 1993Dec 2, 1993Feb 16, 1994
020031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Repeat11$600$420Nov 29, 1993Dec 2, 1993Feb 16, 1994
020041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Repeat11$600$420Oct 14, 1993Dec 2, 1993Feb 16, 1994
020051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Repeat11$600$420Oct 14, 1993Dec 2, 1993Feb 16, 1994
020061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Repeat11$600$420Nov 29, 1993Dec 2, 1993Feb 16, 1994
02007761008003Repeat11$200$150Nov 29, 1993Dec 2, 1993Feb 16, 1994
02008761008003Repeat11$200$150Nov 29, 1993Dec 2, 1993Feb 16, 1994
020091910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01 I
Repeat12$200$150Nov 29, 1993Dec 2, 1993Feb 16, 1994
03010763001002Other11$0$0Nov 29, 1993--
030111910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other12$0$0Nov 29, 1993--
030121910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Other11$0$0Nov 29, 1993--
Apr 16, 1991Planned (H) · Complete scope, Safety#115730467$55019 viol.

Inspection #115730467

Dates

Opened
Apr 16, 1991
Closing Conference Date
Apr 18, 1991
Contested
May 30, 1991
Closed
Aug 20, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
35

Violations and Penalties

Total Violations
19
Violation Types
5 serious, 14 other-than-serious
Initial Penalties
$605
Penalties on Record
$550
Site Address
1376 Nw Conroy St, Madras, OR 97741
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on May 30, 1991. Final orders are recorded through Jul 9, 1991. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (16 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious11$75$75Apr 16, 1991May 30, 1991-
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$105$50May 22, 1991May 30, 1991Jul 9, 1991
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$75$75Apr 18, 1991May 30, 1991-
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$75$75Apr 18, 1991May 30, 1991-
010051910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious135$75$75Apr 18, 1991May 30, 1991-
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIF
Other11$0$0May 22, 1991May 30, 1991-
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0May 22, 1991May 30, 1991-
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other11$0$0Apr 18, 1991May 30, 1991-
02009761008003Other22$0$0May 29, 1991May 30, 1991-
020101910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 A04 I
Other11$0$0Apr 18, 1991May 30, 1991-
020111910.25
Stairways
OSHA citation code: 19100025 D02 VIII
Other11$0$0Apr 18, 1991May 30, 1991-
020121910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01 I
Other11$0$0May 22, 1991May 30, 1991-
020131910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$50$50May 22, 1991May 30, 1991-
020141910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Other11$0$0Apr 18, 1991May 30, 1991-
020157153001001Other11$0$0May 22, 1991May 30, 1991-
02016756009501Other11$0$0May 29, 1991May 30, 1991-

Showing the 16 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus12 citations · $2,925
1910.303Electrical - General Requirements4 citations · $150
1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $0