Skip to content
SafetyRecord logoSafetyRecord
COOPERSTOWN CSD ELEMENTARY SCHOOL
$0
penalties
41
viol.
9
insp.

COOPERSTOWN CSD ELEMENTARY SCHOOL

21 WALNUT ST, COOPERSTOWN, NY 13326

Inspections
9
May 1990 to Jun 2009 · 9 safety, 0 health
Violations
41
across 9 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 21Willful 0Repeat 0Other 20

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 4, 2009Follow-Up (F) · Partial scope, Safety#313389298$00 viol.

Inspection #313389298

Dates

Opened
Jun 4, 2009
Closing Conference Date
Jun 4, 2009
Closed
Jun 4, 2009

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
58

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
611110 Elementary and Secondary Schools

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 21, 2009Planned (H) · Complete scope, Safety#312906985$02 viol.

Inspection #312906985

Dates

Opened
Apr 21, 2009
Closing Conference Date
Apr 21, 2009
Closed
Jun 4, 2009

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
58

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
611110 Elementary and Secondary Schools

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02 I
Serious12$0$0May 21, 2009--
010021910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious12$0$0May 21, 2009--
Apr 19, 2000Follow-Up (F) · Partial scope, Safety#300353067$00 viol.

Inspection #300353067

Dates

Opened
Apr 19, 2000
Closing Conference Date
Apr 19, 2000
Closed
Apr 19, 2000

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
80

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 20, 1999Planned (H) · Complete scope, Safety#124572447$07 viol.

Inspection #124572447

Dates

Opened
Dec 20, 1999
Closing Conference Date
Dec 20, 1999
Closed
Apr 19, 2000

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
80

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious180$0$0Feb 3, 2000--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious180$0$0Feb 25, 2000--
010031910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A03 I
Serious180$0$0Feb 3, 2000--
020011910.144
Safety Color Code for Marking Physical Hazards
OSHA citation code: 19100144 A03
Other180$0$0Feb 25, 2000--
020021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other180$0$0Apr 7, 2000--

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 7, 1996Follow-Up (F) · Partial scope, Safety#115813552$00 viol.

Inspection #115813552

Dates

Opened
May 7, 1996
Closing Conference Date
May 7, 1996
Closed
May 7, 1996

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
78

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 14, 1996Planned (H) · Complete scope, Safety#115813172$010 viol.

Inspection #115813172

Dates

Opened
Feb 14, 1996
Closing Conference Date
Feb 14, 1996
Closed
May 7, 1996

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
78

Violations and Penalties

Total Violations
10
Violation Types
10 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
Stairways
OSHA citation code: 19100025 D01 X
Serious178$0$0Apr 15, 1996--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 F02
Serious178$0$0Apr 15, 1996--
010031910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Serious178$0$0Apr 15, 1996--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious178$0$0Apr 15, 1996--
010051910.176
Handling Materials - General
OSHA citation code: 19100176 A
Serious178$0$0Apr 15, 1996--

Showing the 5 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 13, 1990Follow-Up (F) · Partial scope, Safety#108476813$00 viol.

Inspection #108476813

Dates

Opened
Sep 13, 1990
Closing Conference Date
Sep 13, 1990
Closed
Sep 13, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 22, 1990Follow-Up (F) · Partial scope, Safety#104887518$00 viol.

Inspection #104887518

Dates

Opened
Aug 22, 1990
Closing Conference Date
Aug 22, 1990
Closed
Aug 22, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 18, 1990Planned (H) · Complete scope, Safety#108475427$022 viol.

Inspection #108475427

Dates

Opened
May 18, 1990
Closing Conference Date
May 18, 1990
Closed
Sep 17, 1990

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
22
Violation Types
6 serious, 16 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
21 Walnut St, Cooperstown, NY 13326
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.25
Stairways
OSHA citation code: 19100025 D01 X
Serious470$0$0May 27, 1990--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious170$0$0Jun 8, 1990--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious370$0$0Jun 8, 1990--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious170$0$0Jun 8, 1990--
010051910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious570$0$0Jun 8, 1990--

Showing the 5 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties11 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 11 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order

Showing the 0 FTA rows present in the first 5 citations on this inspection. OSHA's record shows 11 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.37Maintenance, Safeguards, and Operational Features for Exit Routes7 citations · $0
1910.176Handling Materials - General6 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $0

Industry comparison

BLS 2024 survey: elementary and secondary schools reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 4.7%; NAICS 6111 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in COOPERSTOWN, NY