Skip to content
SafetyRecord logoSafetyRecord
WAYLAND TN HIGHWAY DEPT
$0
penalties
70
viol.
15
insp.

WAYLAND TN HIGHWAY DEPT

11118 STATE RTE 21, WAYLAND, NY 14572NAICS 237310 Highway, Street, and Bridge Construction

Inspections
15
Sep 1988 to Feb 2013 · 13 safety, 2 health
Violations
70
across 15 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 43Willful 0Repeat 0Other 27

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 16, 1992Follow-Up (F) · Partial scope, Safety#115911703$00 viol.

Inspection #115911703

Dates

Opened
Jul 16, 1992
Closing Conference Date
Jul 16, 1992
Closed
Jul 16, 1992

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
11118 State Rte 21, Wayland, NY 14572
Industry
237310 Highway, Street, and Bridge Construction

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 19, 1992Planned (H) · Complete scope, Safety#115866162$015 viol.

Inspection #115866162

Dates

Opened
Mar 19, 1992
Closing Conference Date
Mar 19, 1992
Closed
Jul 16, 1992

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
15
Violation Types
13 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
11118 State Rte 21, Wayland, NY 14572
Industry
237310 Highway, Street, and Bridge Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 D02 I
Serious17$0$0Jun 22, 1992--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious17$0$0Jun 1, 1992--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious17$0$0Jun 22, 1992--
010041910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious17$0$0Jun 22, 1992--
010051910.244
Other Portable Tools and Equipment
OSHA citation code: 19100244 A01 II
Serious17$0$0Jun 1, 1992--
010061910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious27$0$0Jun 1, 1992--
010071910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious17$0$0Jun 22, 1992--
010081910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious17$0$0Jun 1, 1992--
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious27$0$0Jun 1, 1992--
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious17$0$0Jun 22, 1992--

Showing the 10 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 18, 1989Follow-Up (F) · Partial scope, Safety#104772355$00 viol.

Inspection #104772355

Dates

Opened
Jan 18, 1989
Closing Conference Date
Jan 18, 1989
Closed
Jan 18, 1989

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
11118 State Rte 21, Wayland, NY 14572
Industry
237310 Highway, Street, and Bridge Construction

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 7, 1988Follow-Up (F) · Partial scope, Safety#104771217$00 viol.

Inspection #104771217

Dates

Opened
Dec 7, 1988
Closing Conference Date
Dec 7, 1988
Closed
Dec 7, 1988

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
11118 State Rte 21, Wayland, NY 14572
Industry
237310 Highway, Street, and Bridge Construction

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Sep 14, 1988Planned (H) · Complete scope, Safety#104790449$011 viol.

Inspection #104790449

Dates

Opened
Sep 14, 1988
Closing Conference Date
Sep 14, 1988
Closed
Jan 20, 1989

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
11
Violation Types
4 serious, 7 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
11118 State Rte 21, Wayland, NY 14572
Industry
237310 Highway, Street, and Bridge Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious27$0$0Nov 2, 1988--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 C04
Serious17$0$0Oct 5, 1988--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious37$0$0Nov 2, 1988--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious47$0$0Nov 2, 1988--
020011910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 B
Other17$0$0Nov 2, 1988--
020021910.244
Other Portable Tools and Equipment
OSHA citation code: 19100244 A01 II
Other47$0$0Nov 2, 1988--
020031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other17$0$0Oct 5, 1988--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other17$0$0Nov 2, 1988--
020051910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other17$0$0Nov 2, 1988--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other17$0$0Oct 5, 1988--

Showing the 10 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties2 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01001#104771217Dec 13, 1988---
02001#104771217Dec 13, 1988---
Inspections 11 to 15 of 15, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment10 citations · $0
1910.1200Hazard Communication6 citations · $0
1910.303Electrical - General Requirements6 citations · $0

Industry comparison

Violations per inspection
This employer4.7
Industry average1.6
Penalties per inspection
This employer$0
Industry average$2,256

Heavy and Civil Engineering Construction, 70,144 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in WAYLAND, NY

All employers in WAYLAND →