STEUBEN CO HIGHWAY DEPT MACHINE REPAIR SHOP
6601 CR 113, BATH, NY 14810
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 23, 1998#124492869Apr 23, 1998Follow-Up (F) · Partial scope, Safety#124492869$00 viol.0 violations$0 in penalties
Inspection #124492869
Dates
- Opened
- Apr 23, 1998
- Closing Conference Date
- Apr 23, 1998
- Closed
- May 8, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Mar 25, 1998#124492844Mar 25, 1998Follow-Up (F) · Partial scope, Safety#124492844$00 viol.0 violations$0 in penalties
Inspection #124492844
Dates
- Opened
- Mar 25, 1998
- Closing Conference Date
- Mar 25, 1998
- Closed
- Mar 27, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Nov 20, 1997#115811408Nov 20, 1997Planned (H) · Complete scope, Safety#115811408$017 viol.17 violations$0 in penalties
Inspection #115811408
Dates
- Opened
- Nov 20, 1997
- Closing Conference Date
- Nov 20, 1997
- Closed
- May 8, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 17
- Violation Types
- 11 serious, 6 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 17 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IIB1 | Serious | 1 | 12 | $0 | $0 | Feb 27, 1998 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 12 | $0 | $0 | Apr 10, 1998 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 12 | $0 | $0 | Feb 27, 1998 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 12 | $0 | $0 | Feb 27, 1998 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 2 | 12 | $0 | $0 | Feb 27, 1998 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Nov 19, 1997#115811382Nov 19, 1997Planned (H) · Complete scope, Safety#115811382$012 viol.12 violations$0 in penalties
Inspection #115811382
Dates
- Opened
- Nov 19, 1997
- Closing Conference Date
- Nov 19, 1997
- Closed
- Mar 27, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 5 serious, 7 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 D01 I | Serious | 1 | 18 | $0 | $0 | Mar 24, 1998 | - | - |
| 01002 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 B03 | Serious | 1 | 18 | $0 | $0 | Mar 24, 1998 | - | - |
| 01003 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C01 | Serious | 2 | 18 | $0 | $0 | Jan 16, 1998 | - | - |
| 01004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Serious | 1 | 18 | $0 | $0 | Mar 24, 1998 | - | - |
| 01005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Serious | 1 | 18 | $0 | $0 | Jan 16, 1998 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 30, 1993#115927733Mar 30, 1993Follow-Up (F) · Partial scope, Safety#115927733$00 viol.0 violations$0 in penalties
Inspection #115927733
Dates
- Opened
- Mar 30, 1993
- Closing Conference Date
- Mar 30, 1993
- Closed
- Mar 30, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Mar 26, 1993#115788861Mar 26, 1993Follow-Up (F) · Complete scope, Health#115788861$00 viol.0 violations$0 in penalties
Inspection #115788861
Dates
- Opened
- Mar 26, 1993
- Closing Conference Date
- Mar 26, 1993
- Closed
- Mar 26, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Sep 24, 1992#115911844Sep 24, 1992Planned (H) · Complete scope, Safety#115911844$015 viol.15 violations$0 in penalties
Inspection #115911844
Dates
- Opened
- Sep 24, 1992
- Closing Conference Date
- Sep 24, 1992
- Closed
- Mar 31, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 15
- Violation Types
- 13 serious, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 15 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.25 Stairways OSHA citation code: 19100025 D01 X | Serious | 2 | 25 | $0 | $0 | Dec 4, 1992 | - | - |
| 01002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 25 | $0 | $0 | Dec 4, 1992 | - | - |
| 01003 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 25 | $0 | $0 | Dec 4, 1992 | - | - |
| 01004 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 25 | $0 | $0 | Dec 4, 1992 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 25 | $0 | $0 | Dec 4, 1992 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 2, 1992#115927402Sep 2, 1992Follow-Up (F) · Partial scope, Safety#115927402$00 viol.0 violations$0 in penalties
Inspection #115927402
Dates
- Opened
- Sep 2, 1992
- Closing Conference Date
- Sep 2, 1992
- Closed
- Sep 2, 1992
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Jun 30, 1992#115866501Jun 30, 1992Referral (C) · Complete scope, Health#115866501$03 viol.3 violations$0 in penalties
Inspection #115866501
Dates
- Opened
- Jun 30, 1992
- Closing Conference Date
- Dec 15, 1992
- Closed
- Mar 30, 1993
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 D01 | Other | 1 | 8 | $0 | $0 | Mar 26, 1993 | - | - |
| 01002 | 1910.1025 Lead OSHA citation code: 19101025 D02 | Other | 2 | 2 | $0 | $0 | Jan 3, 1993 | - | - |
| 01003 | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Other | 2 | 2 | $0 | $0 | Feb 12, 1993 | - | - |
Jun 8, 1992#115926123Jun 8, 1992Planned (H) · Complete scope, Safety#115926123$011 viol.11 violations$0 in penalties
Inspection #115926123
Dates
- Opened
- Jun 8, 1992
- Closing Conference Date
- Jun 8, 1992
- Closed
- Sep 3, 1992
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 12
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 9 serious, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 6601 Cr 113, Bath, NY 14810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 12 | $0 | $0 | Aug 4, 1992 | - | - |
| 01002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 2 | 12 | $0 | $0 | Jul 14, 1992 | - | - |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 12 | $0 | $0 | Jun 30, 1992 | - | - |
| 01004 | 1910.254 Arc Welding and Cutting OSHA citation code: 19100254 D09 III | Serious | 1 | 12 | $0 | $0 | Aug 4, 1992 | - | - |
| 01005 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B01 | Serious | 3 | 12 | $0 | $0 | Jul 14, 1992 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
12 inspections, 1988 to 1998. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.