CREIGHTON POST & PIPE SUPPLY CO.
$750
penalties
11
viol.
3
insp.

CREIGHTON POST & PIPE SUPPLY CO.

WEST HWY. 59, CREIGHTON, NE 68729

Inspections
3
Jul 1986 to Aug 2004 · 2 safety, 1 health
Violations
11
across 3 inspections
Penalties on record
$750
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 17, 2004Planned (H) · No Inspection scope, Safety#306022112$00 viol.

Inspection #306022112

Dates

Opened
Aug 17, 2004
Closing Conference Date
Not recorded
Closed
Aug 18, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
P.o. Box 137, Creighton, NE 68729
Industry
332323 Ornamental and Architectural Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jan 27, 1998Complaint (B) · Partial scope, Health#116008434$75011 viol.

Inspection #116008434

Dates

Opened
Jan 27, 1998
Closing Conference Date
Jan 28, 1998
Closed
Jul 2, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12
Related Activity
2 complaints

Violations and Penalties

Total Violations
11
Violation Types
4 serious, 7 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$750
Site Address
P.o. Box 137, Creighton, NE 68729
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Chromium, Metal and Insoluble Salts40.0012 - 0.0016mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40.0065 - 0.0107mg/m³
Iron Oxide Fume41.8993 - 3.4237mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40.1242 - 0.2004mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40 - 0.0037mg/m³
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40.0118 - 0.0166mg/m³

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Serious110$750$375May 15, 1998--
01001B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious110$0$0May 15, 1998--
01001C1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 II
Serious210$0$0May 15, 1998--
010021910.106
Flammable Liquids
OSHA citation code: 19100106 D04 I
Serious210$750$375Apr 21, 1998--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other610$0$0May 15, 1998--
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other110$0$0Apr 17, 1998--
020031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other11$0$0May 15, 1998--
020041910.141
Sanitation
OSHA citation code: 19100141 A03 I
Other210$0$0Apr 21, 1998--
020051910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A01 II
Other210$0$0Apr 21, 1998--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other11$0$0Apr 21, 1998--
020071910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other110$0$0Jun 30, 1998--
Jul 15, 1986Planned (H) · No Inspection scope, Safety#100043363$00 viol.

Inspection #100043363

Dates

Opened
Jul 15, 1986
Closing Conference Date
Jul 15, 1986
Closed
Jul 15, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
West Hwy. 59, Creighton, NE 68729
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.252Welding, Cutting, and Brazing - General Requirements2 citations · $0
1910.22Walking-Working Surfaces - General Requirements1 citation · $0
1910.38Emergency Action Plans1 citation · $375

Chemical exposure sampling

Samples
48
Substances
12
Inspections
1

Industry comparison

BLS 2024 survey: ornamental and architectural metal work manufacturing reported 4.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 16.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CREIGHTON, NE

All employers in CREIGHTON →