Skip to content
SafetyRecord logoSafetyRecord
FIZZANO BROTHERS, INC.
$17,583
penalties
34
viol.
7
insp.

FIZZANO BROTHERS, INC.

1776 CHESTER PIKE, CRUM LYNNE, PA 19022NAICS 327331 Concrete Block and Brick Manufacturing

Inspections
7
Oct 1974 to Dec 2023 · 4 safety, 3 health
Violations
34
across 7 inspections
Penalties on record
$17,583
latest amounts in DOL records
By classification
Serious 20Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 1, 2023Referral (C) · Partial scope, Safety#347137382$12,4782 viol.

Inspection #347137382

Dates

Opened
Dec 1, 2023
Closing Conference Date
Dec 1, 2023
Final Order
May 28, 2024
Closed
Jun 23, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
27
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$19,196
Penalties on Record
$12,478
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious12$9,598$6,239Jun 18, 2024-May 28, 2024
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious22$9,598$6,239Jun 18, 2024-May 28, 2024
Nov 21, 2023Planned (H) · Complete scope, Health#347119257$00 viol.

Inspection #347119257

Dates

Opened
Nov 21, 2023
Closing Conference Date
Nov 21, 2023
Closed
May 24, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
27

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 25, 2012Planned (H) · Complete scope, Health#336613989$6905 viol.

Inspection #336613989

Dates

Opened
Sep 25, 2012
Closing Conference Date
Oct 2, 2012
Final Order
Mar 28, 2013
Closed
Apr 1, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$918
Penalties on Record
$690
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$918$690Mar 29, 2013-Mar 28, 2013
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious11$0$0Apr 12, 2013-Mar 28, 2013
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious11$0$0Apr 5, 2013-Mar 28, 2013
01001D1910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious11$0$0Mar 18, 2013-Mar 28, 2013
01001E1910.134
Respiratory Protection
OSHA citation code: 19100134 K
Serious11$0$0Mar 29, 2013-Mar 28, 2013
Sep 25, 2012Planned (H) · Complete scope, Safety#336559588$1,4151 viol.

Inspection #336559588

Dates

Opened
Sep 25, 2012
Closing Conference Date
Sep 25, 2012
Final Order
Mar 28, 2013
Closed
Apr 1, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$1,890
Penalties on Record
$1,415
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01
Serious12$1,890$1,415Mar 19, 2013-Mar 28, 2013
Sep 6, 2006Planned (H) · Complete scope, Health#116024993$70011 viol.

Inspection #116024993

Dates

Opened
Sep 6, 2006
Closing Conference Date
Sep 6, 2006
Closed
Jan 22, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60

Violations and Penalties

Total Violations
11
Violation Types
3 serious, 8 other-than-serious
Initial Penalties
$1,225
Penalties on Record
$700
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious112$525$350Nov 29, 2006--
01002A1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02
Serious13$700$350Dec 29, 2006--
01002B1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J02 IV
Serious13$0$0Nov 29, 2006--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other13$0$0Nov 1, 2006--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other120$0$0Nov 4, 2006--
020031910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Other140$0$0Nov 13, 2006--
020041910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C08 I
Other130$0$0Nov 29, 2006--

Showing the 7 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 4, 1997Planned (H) · Complete scope, Safety#301444543$2,30015 viol.

Inspection #301444543

Dates

Opened
Mar 4, 1997
Closing Conference Date
Mar 20, 1997
Closed
Jun 30, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
15
Violation Types
9 serious, 6 other-than-serious
Initial Penalties
$3,825
Penalties on Record
$2,300
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
Ladders
OSHA citation code: 19100023 C01
Serious13$900$600May 20, 1997--
01001B1910.23
Ladders
OSHA citation code: 19100023 C03
Serious24$0$0May 20, 1997--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious15$900$500Jun 30, 1997--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious15$0$0May 20, 1997--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious15$0$0Jun 30, 1997--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious23$675$400May 20, 1997--
01004A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious23$675$400May 20, 1997--

Showing the 7 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 9, 1974Planned (H) · Complete scope, Safety#12700589$00 viol.

Inspection #12700589

Dates

Opened
Oct 9, 1974
Closing Conference Date
Oct 9, 1974
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
31

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1776 Chester Pike, Crum Lynne, PA 19022
Industry
327331 Concrete Block and Brick Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection8 citations · $690
1910.1020Access to Employee Exposure and Medical Records3 citations · $0
1910.147Control of Hazardous Energy (Lockout/Tagout)3 citations · $500

Industry comparison

Violations per inspection
This employer4.9
Industry average3.3
Penalties per inspection
This employer$2,512
Industry average$2,374

Nonmetallic Mineral Product Manufacturing, 17,192 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: concrete pipe, brick, and block manufacturing reported 2.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 21.9%; NAICS 32733 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in CRUM LYNNE, PA

All employers in CRUM LYNNE →